102
MV-1238-1239-5-2018 . © All rights reserved Swim & Fun Scandinavia ApS
UK
Usage parameters d0 to d11
Code Condition
Scope
Remark
d0
IPM temperature
0-120 °C
Real testing value
d1
Water temperature (inlet)
-9 °C ~ 99 °C
Real testing value
d2
Water temperature (outlet)
-9 °C ~ 99 °C
Real testing value
d3
Ambient temperature
-30 °C ~ 70°C
Real testing value
d4
Frequency limitation code
0, 1, 2, 4, 8, 16
Real testing value
d5
Pipe temperature
-30 °C ~ 70 °C
Real testing value
d6
Exhaust gas temperature
0 °C ~ C5 °C (125 °C)
Real testing value
d7
Step of EEV
0~99
N*5
d8
Compressor working frequency
0~99Hz
Real testing value
d9
Compressor current
0~30A
Real testing value
d10
Fan Speed
0-1200 (rpm)
Real testing value
d11
Error code for the last time
All error codes
Remark: d4 Frequency limitation code, 0: No frequency limit; 1: Coil pipe temperature limit; 2: Overheating or overcooling
frequency limit; 4: Drive Current frequency limit; 8: Drive voltage frequency limit; 16:Drive high temperature frequency limit
Usage parameters P0 to P7
Code Name
Area of application
Default
Remark
P0
Mandatory defrosting
0-1
0
0: Default normal operation
1: mandatory defrosting
P1
Work setting
0-1
1
1 Heating mode,
0 Cooling mode
P2
Timer on/off
0-1
0
1 Timer on/off is in opera-
tion, 0 Timer on/off does not
function (The setting of P4
and P5 will not work)
P3
Water pump
0-1
0
1 Always running, 0 De-
pends on the operation of
the compressor
P4
Current time
HH:MM
00:00
0-23:0-59
P5
Timer ON
HH:MM
00:00
0-23:0-59
P6
Timer off
HH:MM
00:00
0-23:0-59
P7
Inlet water temp. correction
-9~9
0
Default setting: 0
Symbol description
Symbol for heat.
The light will be on when it is in operation. When defrosting, the light will
flash.
Symbol for cooling. The light will be on when it is in operation.
Symbol for automatic stop. The light will be on when it is in operation.
Symbol for automatic start, the light will be on when it is in operation.