swiftech MCW5000-64 Скачать руководство пользователя страница 1

 

Swiftech Inc., 1703 E. 28

th

 St., Signal Hill, CA 90755 T. (562) 595-8009 F. (562) 595-8769 

Parts list 

Parts 

QTY 

PARTS 

QTY 

MCW5000-64™ assembly 

Aluminum tension limiter 

6-32 x 1 ¾ Philips screw 

Springs 

Nylon shoulder washers 

Arctic Alumina Thermal compound 

 

This product is intended for expert users. Please consult with a qualified technician for installation. Improper installation may result in 
damage to your components. Swiftech assumes no liability whatsoever, expressed or implied, for the use of these products, nor their 
installation.  The following instructions are subject to change without notice. Please visit our web site at 

www.swiftnets.com

 for 

updates. 

 

1. 

Before you install the MCW5000-64

 water-block:

 

 

a. 

Prepare two pieces of tubing

 of sufficient length to connect 

to the rest of your circuit. The cuts must be square as shown in 
figure 1 or leaks may occur:

 

b

. Install the provided plastic tube inserts

 at each end of the tubes, 

as shown in figure 2: these inserts are absolutely 

imperative 

when 

using any kind of 

soft 

tubing, such as vynil, ClearFlex, Taigon, etc...

  

 

 

Square cut

 

Figure 1

 

 

Figure 2

 

 

 

Figure 3

 

 

Figure 4

 

            

 

Figure 5

 

c

. Spread a little bit of grease

 

or simple 

liquid soap

 around the tubing. It helps pushing 

the tubes in, particularly with Clearflex

 tubing, 

which features a very “sticky” surface. 

d. 

Fully insert both tubes into the fittings

. The tip of the plastic tube inserts should 

be flush with the inlet and outlet openings, as shown in figure 4 above. Inserting the 
tubes requires a firm push, accompanied by a twisting motion.

 

 

 

2. 

Preparing your Motherboard 

 

Remove the existing heat sink

 

 

Carefully clean the CPU.

 

 

Lightly coat the CPU with the provided thermal compound. 

Only a paper-thin

 

coat is necessary

. It should be applied 

using preferably a razor blade, or a credit card, held between thumb and index at a 45-degree angle.

 

 

 

3. 

MCW5000-64™ water-block installation diagram 

The MCW5000-64 water-block bolts onto AMD’s validated plastic retention frame with two screw spring assemblies. 
Please use the retention frame provided by your motherboard vendor. Remove the two existing screws that hold the 
frame in place, place the water-block assembly onto the CPU, and use these two holes to bolt down the spring 
assemblies, as shown on the schematic (figure 7) page. 

 

 

Page 1 of 2 
 
 