background image

11 

 

IV. Assembling the microscope

 

The components for the S7 series microscopes are shipped detached for protection. 
Open the styrofoam packing with care and do not leave any components attached to the 
packing being removed. Do not discard any of the packing materials until all of the 
components have been identified. Refer to the appropriate diagram from Section III to 
identify all the components. 
 
When handling the components, especially the optical pieces, avoid touching any lens 
surfaces with bare hands or fingers, as fingerprints and grease stains affect image 
quality. 
 
Always assemble the microscope on a flat, stable surface.  
 
There is anti-theft design of S7 eyepiece with the eyepiece locking screw in the 
microscope eye tubes. Please loose the cross recessed screw in the tubes and slide 
eyepieces into it. Tighten the locking screw after your eyepiece installation.  
 
Refer to the appropriate diagrams on the following pages for how to assemble the 
pieces for your specific S7 model.  
 
For all models, note that the column stand allows for extreme flexibility in positioning 
once assembled. Loosen the locking screw of the head holder or vertical pole locker 
(boom stand), adjust the height of the head holder and lock the locking screw again. 
Make sure that the support collar is secured firmly below the head holder or boom stand 
main body holder along the vertical post. This is important as this collar keeps the 
microscope from sliding down the column. 
 
 
 
 
 
 
 
 

 
 

 

 

Содержание S7 Series

Страница 1: ...User Guide the S7 Stereo Microscope Series...

Страница 2: ...begin using it For more information about our microscopes software downloads product manuals or customer service requests please visit www swiftoptical com Table of Contents I Prior to use 2 II Specif...

Страница 3: ...the right and left focusing knobs in opposite directions at the same time Doing so will damage the microscope II Specifications The S7 series comes with either a binocular S7 B or a trinocular head S7...

Страница 4: ...le Available additional auxiliary objectives 0 5X WD 165mm 2 0X WD 30mm Illumination options 56 bulb LED ring light 6000 7000K 100 240V 144 bulb LED ring light 6000 7000K 100 240V Stand options Plain...

Страница 5: ...4X 14 3 45X 4 4 22 5X 8 9 90X 2 2 15X 15mm 10 5X 21 4 5 25X 42 8 21X 10 7 67 5X 3 3 33 75X 6 7 135X 1 7 20X 10 14X 14 3 7X 28 6 28X 7 1 90X 2 2 45X 4 4 180X 1 1 Abbreviations WD Working distance Mag M...

Страница 6: ...5 III Parts of the microscope The below diagrams show the various available stand configurations for the S7 binocular and trinocular head models The S7 B with plain stand Fig 1...

Страница 7: ...6 The S7 T with plain stand Fig 2...

Страница 8: ...7 The S7 B with single arm boom stand Fig 3...

Страница 9: ...8 The S7 T with single arm boom stand Fig 4...

Страница 10: ...9 The S7 B with dual arm boom stand Fig 5...

Страница 11: ...10 The S7 T with dual arm boom stand Fig 6...

Страница 12: ...ce There is anti theft design of S7 eyepiece with the eyepiece locking screw in the microscope eye tubes Please loose the cross recessed screw in the tubes and slide eyepieces into it Tighten the lock...

Страница 13: ...12 The S7 B with plain stand Fig 7 Note the ring light should only be attached to the bottom of the microscope head after the head has been securely inserted into the head holder...

Страница 14: ...13 The S7 T with plain stand Fig 8 Note the ring light should only be attached to the bottom of the microscope head after the head has been securely inserted into the head holder...

Страница 15: ...14 The S7 B with single arm boom stand Fig 9 Note the ring light should only be attached to the bottom of the microscope head after the head has been securely inserted into the head holder...

Страница 16: ...15 The S7 T with single arm boom stand Fig 10 Note the ring light should only be attached to the bottom of the microscope head after the head has been securely inserted into the head holder...

Страница 17: ...16 The S7 B with dual arm boom stand Fig 11 Note the ring light should only be attached to the bottom of the microscope head after the head has been securely inserted into the head holder...

Страница 18: ...17 The S7 T with dual arm boom stand Fig 12 Note the ring light should only be attached to the bottom of the microscope head after the head has been securely inserted into the head holder...

Страница 19: ...icroscope along the vertical pole Remember to tighten the locking screw and support collar after adjusting the height of the microscope Turn the zoom to the highest magnification Adjust the focusing k...

Страница 20: ...or lens tissue Stubborn fingerprint smudges or oil marks can be wiped off with lens tissue moistened with a small amount of xylene or a 3 7 mixture of alcohol and ether Never use organic solutions to...

Страница 21: ...same magnification Dirt appears in the field of view Dirt on the specimen Clean the specimen Dirt on the surfaces of eyepiece Clean the surfaces Image is blurry Objective surfaces are dirty Clean the...

Страница 22: ...ides the repair or replacement of warrantied parts for free including labor during the warranty period Proof of original purchase is required Buyers are responsible for shipping to and from our wareho...

Страница 23: ...port menu Disclaimer We are constantly working to improve our instruments and to adapt them in response to customer feedback These improvements occasionally involve small modifications to the mechanic...

Отзывы: