background image

7

23/11/2021                          Swegon reserves the right to alter specifications.

WISE 

Paragon Wall

A1

A2

A1

A2

B1

B2

Cooling and heating on left side”L”, all sizes

 

Cooling on left side”L”, all sizes

Water connection

Water connection on right side (R). 
A1 = Cooling water, supply
A2 = Cooling water, return    

 

 

B1 = Heating water, supply
B2 = Heating water, return    

 

 

Water connection on left side (L). 
A1 = Cooling water, supply
A2 = Cooling water, return    

 

 

B1 = Heating water, supply
B2 = Heating water, return    

Cooling and heating on right side ”R”, all sizes

 

 

 

Cooling on right side ”R”, all sizes

Water connection on right side ”R” 

Water connection on left side ”L”

Water dimensions

Product with factory fitted valves:

 

Length 

Cooling

Heating

(mm)

Return

Return

800, 1100, 1400

DN15 external thread

DN15 external thread

Product without factory fitted valves:

Length

Cooling

Heating

(mm)

Supply and return

Supply and return

800, 1100, 1400

Plain pipe

Plain pipe

(Cu) Ø 12 x 1,0 mm

(Cu) Ø 12 x 1,0 mm

23,5 

315

92,5

92,5

25,6

Connecting water

Connect the water pipes using push-on couplings or 
compression ring couplings when the product is ordered 
without valves. Note that compression ring couplings 
require support sleeves inside the pipes.
Do not use solder couplings to connect the water pipes. 
High temperatures can damage the unit’s existing soldered 
joints. Flexible connecting hoses for water are available for 
flat-end pipes and valves, and can be ordered separately.

15 

A1

A2

B1

B2

A1

A2

 

 

Water connection - CCO-valve. 
A1 = Cooling water, supply
A2 = Cooling water, return    

 

 

B1 = Heating water, supply
B2 = Heating water, return    

 

 

C = CCO valve
D = Flexible hose   

 

D

B1
B2

505050

A1
A2

C

Water connection, CCO-valve

Содержание WISE Paragon Wall 1100

Страница 1: ...r connection on right side R 7 Water connection on left side L 7 Air connection 8 Connection dimensions air 8 Commissioning 10 Air distribution 10 Connections 12 LED Explanation 12 Use 13 Trouble shoo...

Страница 2: ...permissible to insert foreign objects into the product s contactor connections or ventilation openings risk for short circuiting 24 V isolation transformer to be connected should comply with the provi...

Страница 3: ...olume l mm without grill incl grill cooling heating 1100 R A 125 22 6 25 5 1 93 1100 L A 125 22 6 25 5 1 92 1100 R B 125 22 6 25 5 1 93 0 38 1100 L B 125 22 6 25 5 1 92 0 37 1100 R X 125 22 6 25 5 1 9...

Страница 4: ...o alter specifications 23 11 2021 Installation 23 5 315 92 5 92 5 25 6 23 5 315 92 5 92 5 25 6 Cutout dimensions 805 1105 1405 5 300 5 20 789 1123 1423 719 200 200 153 153 439 569 286 7 4 17 130 0 20...

Страница 5: ...5 23 11 2021 Swegon reserves the right to alter specifications WISE Paragon Wall Suspension c c B c c A M8 Length mm A mm B mm 800 778 2 222 5 1100 1078 2 222 5 1400 1378 2 222 5...

Страница 6: ...WISE Paragon Wall 6 Swegon reserves the right to alter specifications 23 11 2021 4 x...

Страница 7: ...DN15 external thread DN15 external thread Product without factory fitted valves Length Cooling Heating mm Supply and return Supply and return 800 1100 1400 Plain pipe Plain pipe Cu 12 x 1 0 mm Cu 12...

Страница 8: ...ns 23 11 2021 Air connection All variants have an air connection 125 The product has the air connection centered on the back of the product for easy access from both ends and back View from the back C...

Страница 9: ...9 23 11 2021 Swegon reserves the right to alter specifications WISE Paragon Wall Supply and extract air kit Supply air Extract air...

Страница 10: ...water on a room level and guarantees the highest level of indoor climate with minimum energy consumption This means that when the installation and pairing of the system are completed no further trimmi...

Страница 11: ...11 23 11 2021 Swegon reserves the right to alter specifications WISE Paragon Wall Grille assembly Click...

Страница 12: ...1 1 2 3 4 5 STATUS COM a b c 2 1 2 1 LED Explanation Not connected paired Colour Type Energized White Permanent Selected in TuneWISE White Flashing fast Prepared to be added to the system White Flashi...

Страница 13: ...Cleaning Ideally the product should be cleaned twice a year by vacuuming the coil to remove loose dust In fibre dense environments a more frequent interval is recommended A simple visual inspection of...

Страница 14: ...cts with CU ver 2 delivered from 01 10 2019 Technical data Max radio frequency output 50 mW Frequency band 2 45 GHz IMS band 2400 2483 MHz Temperature sensor 0 50 C 0 5 C Dynamic pressure sensor 0 300...

Страница 15: ...c standards Immunity for industrial environments EN 61000 6 3 2007 Electromagnetic compatibility EMC Generic standards Emission standard for residential commercial and light industrial environments EN...

Страница 16: ...WISE Paragon Wall 16 Swegon reserves the right to alter specifications 23 11 2021 Maintenance 2 3 1 4...

Отзывы: