Swegon PARASOL EXc Скачать руководство пользователя страница 6

PARASOL 

EXc

6

Swegon reserves the right to alter specifications                          20200903

PARASOL EX c 690 MF 
Single-module unit/Enmodulsenhet

Type/Modell Nozzle/Dysa

Side/Sida

k-factor/-faktor

MF

L

-

0,253

MF

M

-

0,440

MF

H

-

0,693

MF

C

-

0,000

PARASOL EX c 1290 MF  
Double-module unit/Tvåmodulsenhet

Type/Modell Nozzle/Dysa

Side/Sida

k-factor/-faktor

MF

L

1&3 short/kort

0,176

MF

L

2&4 long/lång

0,464

MF

M

1&3 short/kort

0,253

MF

M

2&4 long/lång

0,667

MF

H

1&3 short/kort

0,429

MF

H

2&4 long/lång

1,131

MF

C

1, 2, 3, 4

0,000

PARASOL EX c 1290 HF 
Double-module unit/Tvåmodulsenhet

Type/Modell Nozzle/Dysa

Side/Sida

k-factor/-faktor

HF

L

1&3 short/kort

0,253

HF

L

2&4 long/lång

0,667

HF

M

1&3 short/kort

0,440

HF

M

2&4 long/lång

1,160

HF

H

1&3 short/kort

0,693

HF

H

2&4 long/lång

1,827

HF

C

1, 2, 3, 4

0,000

PARASOL EX c 1290 PF 
Double-module unit/Tvåmodulsenhet

Type/Modell Nozzle/Dysa

Side/Sida

k-factor/-faktor

PF

L

1&3 short/kort

0,85

PF

L

2&4 long/lång

2,22

PF

M

1&3 short/kort

0,99

PF

M

2&4 long/lång

2,62

PF

H

1&3 short/kort

1,21

PF

H

2&4 long/lång

3,20

PF

C

1, 2, 3, 4

0,000

Side/Sida 
 1   2   3   4

1

2

4

3

Water/ Vatten

Air/ Luft

Air/ Luft

Commissioning / Injustering

 k-factor/-faktor HLMH = 0,693+0,667+0,440+1,827=

3,63

Example Product Code/ Exempel, produktkod: 
PARASOL EX c 1290-A-HF-HLMH 

Side/Sida 1 = H

k=0,693

Side/Sida 2 = L

k=0,667

Side /Sida 3 = M

k=0,440

Side /Sida 4 = H

k=1,827

Air connection side 2 (standard) 

Luftanslutningssida 2 (standard)

Air connection side 4 

Luftanslutningssida 4

1

2

4

3

Water/ Vatten

Air/ Luft

Air/ Luft

Содержание PARASOL EXc

Страница 1: ...PARASOL EXc Installation Commissioning Maintenance 20200901 Art 942428008 A B A1 B1 B2 A2 Installation Montering ...

Страница 2: ...PARASOL EXc 2 Swegon reserves the right to alter specifications 20200903 A3 A4 A5 A6 B3 B4 M8 MF HF Ø125 PF Ø160 ...

Страница 3: ...3 20200903 Swegon reserves the right to alter specifications PARASOL EXc A7 B5 A8 B6 A9 B7 A10 B8 TORX T 25 1 x 8 690 1290 side 2 sida 2 1290 side 4 sida 4 Left ...

Страница 4: ...PARASOL EXc 4 Swegon reserves the right to alter specifications 20200903 A11 B9 A12 B10 A13 B11 A14 B12 ...

Страница 5: ...reserves the right to alter specifications PARASOL EXc A16 B14 A15 B13 A17 B15 Equipped with connection casing option Utrustad med kanalkåpa tillbehör Equipped with standard cover plate Utrustad med täckplåt som standard ...

Страница 6: ...ong lång 0 667 HF M 1 3 short kort 0 440 HF M 2 4 long lång 1 160 HF H 1 3 short kort 0 693 HF H 2 4 long lång 1 827 HF C 1 2 3 4 0 000 PARASOL EX c 1290 PF Double module unit Tvåmodulsenhet Type Modell Nozzle Dysa Side Sida k factor faktor PF L 1 3 short kort 0 85 PF L 2 4 long lång 2 22 PF M 1 3 short kort 0 99 PF M 2 4 long lång 2 62 PF H 1 3 short kort 1 21 PF H 2 4 long lång 3 20 PF C 1 2 3 4...

Страница 7: ...7 20200903 Swegon reserves the right to alter specifications PARASOL EXc Nozzle configuration Dyskonfiguration H M C L H M C L q k p l s i p Pa i k q 2 pi Pa q l s k k factor faktor 1 x 8 T 25 ...

Страница 8: ...PARASOL EXc 8 Swegon reserves the right to alter specifications 20200903 2 1 3 5 4 Maintenance Skötsel 6 7 ...

Отзывы: