5. Use

Swegon CASA cooker hoods feature a touch 
panel (except Tango), from where you can 
control the functions on the cooker hood 
and ventilation unit. The signal lamps on the 
panel are dimmed automatically when the 
hood is not in use. The Tango hood offers the 
same control functions and indications, but it 
is operated by buttons located on the side of 
the hood.

1.  Selection of fan speed. 

On a ventilation 

system connected to a Swegon CASA 
ventilation unit the operating modes Away, 
Home or Boost can be selected. The period 
for operation at boosted speed is preset to 
60 minutes, after that period the ventila-
tion unit returns to the Home speed.

2.  Fan speed indication.

 

The signal lamp indicates the speed of the 
fans operating in the ventilation unit. From 
left to right, the lamps indicate the Away, 
Home and Boost fan speeds.

3.  Cooker hood damper control.

 

The continuously open period for the 
cooker hood’s damper is selectable in three 
settings: 30, 60 or 120 minutes. Each press 
of the button increases the damper-open 
time one step and the fourth press of the 
button closes the damper. Long press the 
control button to keep the damper open 
for 10 hours (to cool during the summer, 
the function should not be used during the 
heating season).

4.  Open damper time indication.

 

The number of signal lamps indicate the 
continuous open period selected for the 
damper. The damper is closed if no lamp 
is lit.  
1 lamp = 30 minutes 
2 lamps = 60 minutes 
3 lamps = 120 minutes 
lamp 1 + lamp 3 = 10 h

5.  Control of the cooker hood lighting. 

The hood’s lighting is switched on and off 
with a button. The factory default of the 
lighting output is 75 %.  

5

1

2

3

4

The lighting output can be regulated with 
a long press on the button, the brightness 
then changes. Pressing the button again 
changes the brightness in the other direc-
tion. When the brightness is at the right 
level, wait a moment without pressing the 
button until the light flashes to indicate 
the setting has been saved.

Functions on the SMART ventilation unit

 

The functions in a ventilation unit that are con-
trolled with cooker hood are indicated as follows:

•  Away or Boost mode’s lamp is lit 

slightly

: The Smart function controls the 

ventilation to higher or lower values. If you 
wish to continue normal operations you 
can override the Smart functions with the 
fan speed selector button.

•  All lamps flashing

: there is a serious mal-

function in the unit, contact an authorised 
service company.

•  Fan speed indication lamps flashing

the unit indicates a service requirement. 
When a service has been carried out this is 
acknowledged by pressing the fan speed 
selector button for 5 seconds.

•  Away mode lamp flashing

: the unit is 

shut-off. The unit can be started by press-
ing the fan speed selector button.

6. Service and maintenance

Make sure that the cooker hood and grease 
filter are cleaned regularly. Otherwise the 
capacity for capturing cooking odours reduces 
significantly and the collected grease can 
represent a fire risk.

Surfaces

 

Clean the surfaces of the cooker hood with a 
damp cloth and mild washing-up liquid. Do 
not use polish or solvents when cleaning.

Grease filter

 

Under normal conditions the grease filter 
should be cleaned about twice per month. 
Clean the filter through washing by hand in 
warm water. If a grease filter is cleaned in a 
dishwasher this may cause the colour on the 
surface of the filter to change.

Содержание CASA Smart Sensor

Страница 1: ...P_Hoods_l u 2020 12 22 K SIKIRJA HANDBOK FI SE Blues Salsa Samba Tango Jazz Swegon CASA Smart H NDBOK HANDBOOK NO EN...

Страница 2: ...or the cooker manufacturer Always consult your local fire consultant prior to instal lation if the relative space is smaller than 500 mm between the cooker hood and the hob Replacement air Ensure suf...

Страница 3: ...sories 44 7 1 External control functions 44 7 2 Safera safety technology 44 7 3 Twist fan unit 44 7 4 ILVA transformer unit 44 7 5 Ext out relay for 230 V 44 8 Technical data 45 8 1 Capacity for captu...

Страница 4: ...used for controlling ventilation units equipped with Smart control technology EC power roof ventilator Swegon CASA cooker hoods can be used to control a power roof ventilator equipped with an EC fan...

Страница 5: ...on is balanced when the cooker hood is used as the excess extract air that passes via the hood causes negative pressure in the home Balancing occurs automatically when the cooker hood is connected to...

Страница 6: ...on shows which mode is being set NOTE The fan speeds for the operating modes can only be set in the order low to high for example the Away mode speed cannot be higher than the Home mode speed Increase...

Страница 7: ...ting is switched on and off with a button The factory default of the lighting output is 75 5 1 2 3 4 The lighting output can be regulated with a long press on the button the brightness then changes Pr...

Страница 8: ...erial and manufacturing faults is limited to the repair or 7 Accessories POWER 24 VDC EXT OUT NO NO CONTROL max 30 V 5 A replacement of the defective product unless compulsory legislation states other...

Страница 9: ...3141 3 2017 75 48 l s Odour capture Airflow rate l s according to EN13141 3 2017 75 48 l s 30 40 50 60 70 80 90 10 15 20 25 30 35 40 Odour capture Airflow rate l s according to EN13141 3 2017 75 51 l...

Страница 10: ...0 10 100 Airflow rate l s Pressure drop Pa Salsa Airflow rate l s Pressure drop Pa LWA 20 LWA 30 LWA 40 LWA 50 1 10 100 10 100 Tango Airflow rate l s Pressure drop Pa LWA 20 LWA 30 LWA 40 LWA 50 1 10...

Страница 11: ...20 40 60 80 100 120 140 160 180 200 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Air flow rate l s Pressure differential Pa Air flow rate l s Pressure differential Pa Open holes in the damper 1 2 3 4 5 6...

Страница 12: ...or EC power roof ventilator 0 10 VDC 4 Ext in control of damper and lighting with potential free contact signal 5 Ext out damper position signal normally open Connector in accessory bag POWER 24 VDC...

Страница 13: ......

Страница 14: ......

Отзывы: