0
50
100
150
200
250
300
350
400
450
500
0
20
40
60
80
100
120
140
100%
87%
81%
76%
71%
67%
63%
60%
57%
54%
50%
46%
Extract air
A
vailable pr
essur
e, Pa
Airflow, l/s
7. Technical data
7.1 Sizing
500
450
400
350
300
250
200
150
100
50
0
0 20 40 60 80 100 120 140
100 %
87 %
81 %
76 %
71 %
67 %
63 %
60 %
57 %
54 %
50 %
46 %
Supply air
A
vailable pr
essur
e, Pa
Airflow, l/s
Power consumption
Total power consumption, W
Airflow, l/s
0
50
100
150
200
250
300
0
20
40
60
80
100
120
140
100%
87%
81%
76%
71%
67%
63%
60%
57%
54%
50%
46%
Fan setting
%
Sound power level broken down into octave bands, L
wokt
, dB
Weighted sound
power level,
L
WA
, dB(A)
63
Hz
125
Hz
250
Hz
500
Hz
1000
Hz
2000
Hz
4000
Hz
8000
Hz
54
67
60
55
50
48
42
36
22
54
57
67
63
57
52
51
45
39
27
56
60
67
63
58
53
52
46
41
29
57
63
67
65
60
54
53
48
43
32
58
67
71
66
61
56
55
50
45
35
60
71
72
68
62
57
56
52
46
36
61
76
74
70
64
59
57
54
48
38
63
81
75
71
65
59
57
54
48
40
64
87
77
73
67
61
59
56
50
42
65
100
78
75
69
63
60
58
52
44
67
Sound emitted to supply air duct
Acoustical performance
Thick line = SFP 2.0 or lower.
R120.211112
Swegon reserves the right to alter specifications.
www�swegon�com 19
Содержание CASA R120
Страница 1: ...Instructions for installation operation and maintenance Swegon CASA R120 R120_g_EN m ...
Страница 30: ...Swegon reserves the right to alter specifications 30 www swegon com R120 211112 ...
Страница 31: ...R120 211112 Swegon reserves the right to alter specifications www swegon com 31 ...
Страница 32: ...www swegon com ...