Swegon ADAPT Colibri c Скачать руководство пользователя страница 4

4

Swegon reserves the right to alter specifications. 

20120717 

www.swegon.com

WISE

  20

Master

  21

Slave

  22

Slave

   23

Modbus

5

1

6

 1    2    3   4    5    6    7    8    9  10  11  12  13  14  15  16 

1

2

6

5

4

3

9

8

7

5

5

7

2

2

10

11

5

-  + C

A1  A2  1  3

G

G0

OUT1

12

6

Figure 7. Wiring of Master/Slave air diffusers and accessories.

1. ADAPT Master air diffuser 
2. ADAPT Slave air diffusers 
3. CONNECT Adapt, wiring terminals 
4. 230-24 V AC Transformer 
5. LINK Adapt (5 m long RJ45 cable) 
6. LINK Modbus (5 m long RJ12 cable) 
7. DETECT Quality (3 VA) or TUNE Temp (1 VA) 
8. ACTUATOR, Radiator control (max 3 valves at 6 VA) 
9. ADAPT Relay, relay for lighting 
10.Connection to main control system (Modbus RTU) 
11. SPLIT Link RJ45 
12. SPLIT Modbus RJ12, max. stab length, 10 m.

Содержание ADAPT Colibri c

Страница 1: ...rivets The diffuser should be turned so it s hinges C figure 2 face the same direction as the inlet of the commissioning box Readjust the hanger rods of the commissioning box if needed so that the air diffuser is firmly positioned against the false ceiling or the frame work of the modular suspended ceiling 3 Remove the frontplate section of the air diffuser by applying the Quick Access principle s...

Страница 2: ...de the light emitting diode shines orange The different LED indications Steady green LED Normal operation the air diffuser is operating normally Flashing green LED The air diffuser has just been ener gised and calibration is in progress Steady red LED Function failure see separate docu mentation for TUNE Adapt Steady orange LED The commissioning mode max airflow Flashing orange LED Other commissio...

Страница 3: ... longer distances are required All cables and contacts are different so that they will not be confused or incorrectly connected Electrical data ADAPT is supplied with power via the junction box See the wiring diagram in figure 7 or relevant diagram from the Swegon Templates application containing details for the specific installation It is important that cables with appro priate cross sectional ar...

Страница 4: ...er Slave air diffusers and accessories 1 ADAPT Master air diffuser 2 ADAPT Slave air diffusers 3 CONNECT Adapt wiring terminals 4 230 24 V AC Transformer 5 LINK Adapt 5 m long RJ45 cable 6 LINK Modbus 5 m long RJ12 cable 7 DETECT Quality 3 VA or TUNE Temp 1 VA 8 ACTUATOR Radiator control max 3 valves at 6 VA 9 ADAPT Relay relay for lighting 10 Connection to main control system Modbus RTU 11 SPLIT ...