13
8. OPERATION :
8.1 Control panel & display:
All settings & programming is made with the use of the control panel & the
alphanumerical display.
SWITCH ON:
Plug the T26 into a power socket with the appropriate voltage. NOTE: The
machine consumes 2,600 Watts = 11 Amps at 230V and NO fan connected.
•
Auto-ON: If the machine has been disconnected from mains, it will automatically switch ON
when the plug is connected to a mains socket. The GREEN “standby” indicator illuminates.
•
From Standby mode (RED “standby” indicator illuminates): Press and hold the “OK” switch
until the “standby” indicator illuminates GREEN.
The T26 will require approximately 8 minutes to heat to a minimum operational temperature,
and approximately 10 minutes to heat to its highest temperature.
STANDBY INDICATOR:
•
No indication: The machine is disconnected from mains.
•
RED: Standby.
•
GREEN: Power ON.
READY INDICATOR:
•
Until the GREEN “ready” indicator starts to flash, the pumps are unable to run.
•
A flashing indicator indicates that the machine is able to produce fog, but the machine is still
heating and is not yet at its full capacity.
•
The indicator illuminates at highest temperature. This indicates maximum fog capacity.
•
The indicator will start to flash during operation. This is normal, and indicates the machine is
re-heating.
TIMER INDICATOR:
•
YELLOW: Timer is in operation.