SWARCO Caiman Скачать руководство пользователя страница 6

 
 
 

www.swarco.com 

SWARCO TRAFFIC SYSTEMS GMBH, Niederkircher Straße 16, D-54294 Trier, Germany 
T. +49-651-21002-0, +49-651-21002-999, E. [email protected] 
 

6/20 

 

1.2.2  Removing unnecessary wires 

 

Figure 14: Cable without unnecessary wires. Only wires given in Table 1 are needed 

 

Pin No. 

Function 

Wire Color  
(Lapp type 2170217) 

CAN H 

green 

CAN L 

yellow 

RS485 H 

gray 

RS485 L 

pink 

Power + 

red 

Power - 

blue 

Table 1: Pinout of terminal block connector 

 

1.2.3  Connecting Cable and Junction Box 

 

Figure 15: Cable connected to the junction box with tightened connector and tightened cord grip 

 

1.2.4  Removing the insulation of the wires 

 

Figure 16: Wire with removed insulation 

 

Содержание Caiman

Страница 1: ...SWARCO CAIMAN Junction Box Installation CAIMAN WIDE BEAM STOP MOTION RADAR DETECTOR Caiman_JunctionBox Installation_BE_00 ...

Страница 2: ...1 2 6 Connected Junction Box 8 1 3 Placing the Gasket 8 1 4 Connecting Junction Box and CAIMAN 9 1 5 Attaching the Sensor to the Bracket 10 1 6 Attaching the Sensor to the Pole 10 2 Detector Type CAIMAN PLUS 11 2 1 Identifying System Components 11 2 2 Connecting Cable and Junction Box 13 2 2 1 Removing the cable shielding Preparing the braid 13 2 2 2 Removing unnecessary wires 14 2 2 3 Removing th...

Страница 3: ...rmany T 49 651 21002 0 49 651 21002 999 E detection swarco de 3 20 1 Detector Type CAIMAN 1st Generation 1 1 Identifying System Components Figure 1 e g CAIMAN M36 front Figure 2 e g CAIMAN M36 back Figure 3 e g BFW_Caiman_36S Figure 4 Screws M3x8 eight screws required Figure 5 Gasket ...

Страница 4: ...6 D 54294 Trier Germany T 49 651 21002 0 49 651 21002 999 E detection swarco de 4 20 Figure 6 RD_Caiman_JB_3070 RD_Caiman_JB_36 Figure 7 Female blade terminal 6 3mm Figure 8 Blade pin 6 3mm Figure 9 Cable Lapp cable UNITRONIC BUS IBS Yv COMBI type 2170217 recommended ...

Страница 5: ... 1 Removing the shielding Figure 10 Cable with removed shielding Figure 11 Cable with removed braid step not required if braid shall be connected to the Junction Box 1 2 1 2 Preparing the braid If the braid of the homerun cable shall be connected to the Junction Box please follow the following steps Figure 12 The braid of the homerun cable is not cut off but twisted instead Figure 13 A female blad...

Страница 6: ...Only wires given in Table 1 are needed Pin No Function Wire Color Lapp type 2170217 1 CAN H green 2 CAN L yellow 3 RS485 H gray 4 RS485 L pink 5 Power red 6 Power blue Table 1 Pinout of terminal block connector 1 2 3 Connecting Cable and Junction Box Figure 15 Cable connected to the junction box with tightened connector and tightened cord grip 1 2 4 Removing the insulation of the wires Figure 16 W...

Страница 7: ...ires to the terminal block Figure 17 Usage of the screw driver to insert a wire into the terminal Figure 18 Usage of the screw driver to insert a wire into the terminal Figure 19 Routing of the cable wires inside the junction box Figure 20 For the connection of the braid a blade pin 6 3mm is attached to the junction box Figure 21 Blade terminal connected to the blade pin ...

Страница 8: ... 0 49 651 21002 999 E detection swarco de 8 20 1 2 6 Connected Junction Box Figure 22 Wires connected to the Junction Box according to Table 1 Figure 23 Wires connected to the Junction Box including connected braid 1 3 Placing the Gasket Figure 24 Junction Box with gasket placed inside the prepared slot ...

Страница 9: ...e CAIMAN Screw each corner of the JBox onto the sensor Arrows on the figure indicate where the screws should go Note the arrow indicating the top of the sensor shall point in the same direction as the arrow indicating the top of the JBox The arrow on the figure shows where the indication can be found at the sensor Attention After the sensor connector is attached to the JBOX do not further turn or ...

Страница 10: ...e bracket side Figure 28 Sensor attached to the bracket back 1 6 Attaching the Sensor to the Pole Figure 29 Sensor attached to the pole Screw each corner of sensor onto the bracket with the back of the sensor looking into the bracket Arrows on the figure indicate where the screws should go The sensor is fixed to the bracket with the cable looking downwards The sensor is fixed to the pole with the ...

Страница 11: ...9 651 21002 0 49 651 21002 999 E detection swarco de 11 20 2 Detector Type CAIMAN PLUS 2 1 Identifying System Components Figure 30 e g CAIMAN PLUS M100 front Figure 31 e g CAIMAN PLUS M100 back Figure 32 BFW_CaimanP_S for CAIMAN PLUS Figure 33 Screws M3x8 Eight screws required Figure 34 Gasket ...

Страница 12: ...S GMBH Niederkircher Straße 16 D 54294 Trier Germany T 49 651 21002 0 49 651 21002 999 E detection swarco de 12 20 Figure 35 RD_CaimanP_JB Figure 36 Female blade terminal 6 3mm Figure 37 Blade pin 6 3mm Figure 38 Cable Lapp cable 12 poles ...

Страница 13: ... 1 Removing the shielding Figure 39 Cable with removed shielding Figure 40 Cable with removed braid step not required if braid shall be connected to the Junction Box 2 2 1 2 Preparing the braid If the braid of the homerun cable shall be connected to the Junction Box please follow the following steps Figure 41 The braid of the homerun cable is not cut off but twisted instead Figure 42 A female blad...

Страница 14: ... Pin No Function Wire Color MEDI type KU110C12J001 1 Sensor Ethernet TX H gray red 2 Sensor Ethernet TX L red blue 3 Sensor RS485 RX L pink 4 Sensor RS485 RX H gray 5 Sensor RS485 TX L brown 6 Sensor RS485 TX H white 7 Sensor_GND blue 8 Sensor_VCC red 9 Sensor Ethernet RX L black 10 Sensor Ethernet RX H purple 11 CAN H green 12 CAN L yellow Table 2 Pinout of terminal block connector 2 2 3 Removing...

Страница 15: ...02 999 E detection swarco de 15 20 2 2 4 Connecting the wires to the terminal block Figure 45 Usage of the screw driver to insert a wire into the terminal Figure 46 Usage of the screw driver to insert a wire into the terminal Figure 47 For the connection of the braid a blade pin 6 3mm is attached to the Junction Box ...

Страница 16: ... 0 49 651 21002 999 E detection swarco de 16 20 Figure 48 Blade terminal connected to the blade pinConnected Junction Box Figure 49 Wires connected to the Junction Box according to Table 2 including connected braid 2 3 Placing the Gasket Figure 50 Junction Box with gasket placed inside the prepared slot ...

Страница 17: ...ices check the keying of the connector first Note Only if the matching JBOX variant should be mounted to the UMRR the markings indicating the Top pointing to the same direction Attention CAIMAN PLUS applies to following variant RD_CaimanP_JB Screw each corner of the Junction Box onto the sensor Arrows on the figure indicate where the screws should go Attention After the sensor connector is attache...

Страница 18: ...e bracket side Figure 54 Sensor attached to the bracket back 2 6 Attaching the Sensor to the Pole Figure 55 Sensor attached to the pole The sensor is fixed to the pole with the cable looking downwards The sensor is fixed to the bracket with the cable looking downwards Screw each corner of sensor onto the bracket with the back of the sensor looking into the bracket Arrows on the figure indicate whe...

Страница 19: ...H Niederkircher Straße 16 D 54294 Trier Germany T 49 651 21002 0 49 651 21002 999 E detection swarco de 19 20 3 Detector Type CAIMAN PRO Description is in preparation and will follow soon If you have any kind of question please contact SWARCO ...

Страница 20: ...cts may due to specific applications and due to specific surroundings deviate from the statements made herein It is important that customer user invents and certifies its own installation test or other procedures to validate the performance of the Products in the particular specific application before commercialization Although Products are well optimized to be used for the intended applications s...

Отзывы: