Swagelok RD(H)15 Series Скачать руководство пользователя страница 21

21 

 

Troubleshooting

 

 

Symptom 

Cause 

Remedy 

The outlet pressure creeps up, 
without adjusting dome pressure. 

A damaged poppet or seat. 

Replace the poppet and/or seat. 

Leakage around the body plug. 

A damaged O-ring. 

Replace the O-ring. 

Leakage between the body and 
the dome. 

A damaged diaphragm. 

Replace the diaphragm.  

Insufficient torque on the cap 
screws. 

Tighten the cap screws per Table 2. 

Controlled pressure drops off 
sharply even when the flow is 
within regulator capabilities. 

The system filter element is 
clogged. 

Replace the system filter. 

The required outlet pressure 
cannot be reached. 

The inlet pressure to the 
regulator is not high enough. 

Ensure that the inlet pressure to the 
regulator is equal to or greater than the 
desired set pressure. 

The outlet pressure rises too 
much when going from a dynamic 
to a static situation. 

There is too much flow in the 
dynamic situation. 

A larger regulator or parallel regulator is 
required. 
Review application flow capacity and 
contact your local Swagelok distributor. 

The outlet pressure does not drop 
when the pressure in the dome is 
lowered. 

The regulator is non-venting. 

A shutoff valve in the outlet line must be 
opened to reduce the outlet pressure. 

The outlet pressure has changed 
without adjusting the dome 
pressure. 

Changes to the inlet pressure 
may result in changes to the 
outlet pressure. 

Maintain a constant inlet pressure to the 
regulator. See 

Points of Attention 

Before Operation

” about 

dependency

Changes to the flow may 
result in changes to the outlet 
pressure. 

Maintain a constant flow through the 
regulator. See 

Points of Attention 

Before Operation

” about 

droop

No pressure regulation occurs 
with an external feedback 
regulator 

The outlet line has not been 
connected to the external 
feedback port. 

Connect the outlet line to the external 
feedback port. See 

External Feedback

 

for installation details. 

 

Table 3 

Содержание RD(H)15 Series

Страница 1: ...RD H 10 15 Pressure Reducing Regulator User Manual Read the complete manual before installing and using the regulator...

Страница 2: ...dia should be free of excessive moisture to prevent icing at high flow Always wear the appropriate protective clothing including safety glasses gloves etc if required Follow the applicable safety and...

Страница 3: ...n 10 Points of Attention Before Operation 10 Adjusting the Set Pressure 10 Maintenance 11 Required Tools for Maintenance 11 Points of Attention Before Removal from the System 12 Removal from the Syste...

Страница 4: ...in product failure Standard Features Bolted construction Stainless steel as standard Fully serviceable Diaphragm sensing Balanced poppet Pilot regulator Dynamic regulation Additional Options The regu...

Страница 5: ...ions and its accessories are undamaged Verify that the regulator and its accessories are suitable for the system operating pressure and temperature and have suitable connections At the time of deliver...

Страница 6: ...his setup is not suitable for liquid applications Ratio control In this setup a ratio pilot regulator fed from the system pressure is used to control the dome pressure The ratio pilot can be controlle...

Страница 7: ...chematic Fig 2 External Dome Control Schematic Fig 3 Pilot regulator Dynamic Regulation venting to the outlet line Dome regulator Pilot regulator Dynamic Regulation venting to atmosphere Dome regulato...

Страница 8: ...c Fig 4 Ratio Control Schematic Fig 5 Electronic pilot regulator 4 20mA 0 10V 4 20mA 0 10V Dome regulator Pressure transducer Ratio regulator Electronic pilot regulator 4 20mA 0 10V 4 20mA 0 10V Dome...

Страница 9: ...al feedback should be 3 8 in or 1 2 in or the metric equivalent CAUTION When using a regulator with external feedback ensure that the outlet line is connected to the external feedback port before appl...

Страница 10: ...sting the Set Pressure The set pressure is the desired outlet pressure of the regulator To set the regulator ensure that the supply pressure is greater than the required set pressure but does not exce...

Страница 11: ...mum either during commissioning or normal operation Swagelok recommends having maintenance kits readily available on site The need for maintenance kits is particularly important during the commissioni...

Страница 12: ...TION The product can be hot or cold depending on the environmental temperature and the process media temperature Take the necessary precautions before operating or touching the product Removal from th...

Страница 13: ...ng B1 B2 C1 Lubricate 13 Retaining ring C1 14 Diaphragm plate C1 15 Diaphragm B1 B2 C1 C3 16 Dome plate N A 17 Dome N A 18 BSP blind plug O ring B1 B2 C1 19 Blind plug N A NPT 15 20 Wrap threads in 2...

Страница 14: ...14 RD H 10 and RD H 15 Series Exploded View Fig 7...

Страница 15: ...15 Integral Pilot Regulator Assembly Exploded View Fig 8...

Страница 16: ...16 RDH10 Series Standard Section View Fig 9...

Страница 17: ...17 RD15 Series External Feedback Option Section View Fig 10...

Страница 18: ...ertion tool remove the seat 7 and seat O ring 8 5 Remove the cap screws 21 to remove the dome 17 dome plate 16 diaphragm 15 and diaphragm plate 14 6 Remove the retaining ring 13 to remove the body pla...

Страница 19: ...16 centrally onto the diaphragm 15 then cover with the dome 17 Orient the dome ports per Fig 8 13 Lightly lubricate the cap screw threads 21 then use them and the washers 20 to secure the dome 17 to t...

Страница 20: ...ely 14 5 psig 1 bar on the regulator and close the downstream shutoff valve 4 Monitor the outlet pressure An increase in pressure over time indicates a seat leak 5 Repeat the procedure with the highes...

Страница 21: ...e is too much flow in the dynamic situation A larger regulator or parallel regulator is required Review application flow capacity and contact your local Swagelok distributor The outlet pressure does n...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...acked by The Swagelok Limited Lifetime Warranty For a copy visit swagelok com or contact your authorized Swagelok representative Swagelok Snoop TM Swagelok Company Krytox TM The Chemours Company 2018...

Отзывы: