Swagelok KHF Series Скачать руководство пользователя страница 5

Reassembly

      

 

 

NOTICE

    

 Ensure all parts and tools are free of debris or 
damage.

10.  

 Insert the inlet 

filter

 into the 

inlet

 (marked ‘HP’) of the body 

using the filter insertion tool.

      

 

 

NOTICE

      

Do not insert the inlet filter with a sharp tool. 
Damage to the filter could result.

11.   Insert  the 

poppet seal and spring

 into the 

body

 using the 

poppet seal insertion tool

 with the open end of the poppet 

seal and spring facing up.

12.   Insert  the 

seat

 with the groove facing up into the 

seat 

retainer.

13.   Place  the 

poppet

 through the 

seat retainer

. Then place the 

spring retainer, 

the

 poppet spring 

and the

 poppet seal 

retainer

 onto the exposed end of the poppet.

14.   Invert  the 

body

 and thread the 

seat assembly

 into the 

body.

15.   Tighten  the 

seat assembly

 to 30 ft·lb (40 N·m, 4 m·kg).

      

NOTICE

    

  Do not damage the diaphragm sealing face on the 
body. Leakage could result.

16.   Install  the 

diaphragm

 on the 

body

 with the large 

convolution facing towards the body.

17.   Install  the 

stop plate 

onto the 

diaphragm 

with the 

boss

 on 

the stop plate facing away from the diaphragm.

Seat

Seat retainer

Groove

Seat assembly

Body

Filter insertion tool

Inlet filter

HP

Inlet

Spring retainer

Poppet spring

Poppet

Poppet seal retainer

Seat retainer

Stop plate

Diaphragm

Boss

5

Seat retainer spanner

Diaphragm

Body

Large convolution

Body

Poppet seal 
and spring

Poppet seal 
insertion tool

Open end up