5
Installation
CAUTION
Do not use the regulator as a shutoff device. A level of leakage across the regulator seat can
occur during normal operation.
Points of Attention Before Installation
This regulator can be equipped with a variety of different options and connections. Before installing the
regulator you should fully understand the functions of the supplied options and the suitability of your particular
regulator for the intended application.
-
The preferred mounting position of the regulator is horizontal with the spring housing facing upwards per
Fig 2. Alternative mounting positions may increase the risk of component wear.
-
It may be necessary to remove the regulator from the system during maintenance or service. Ensure that
this is possible.
-
The regulator is suitable for gases and liquids. Ensure compatibility between the regulator
’s materials of
construction and the system media.
Installation
-
Verify that the regulator, its connections, and any accessories are undamaged.
-
Verify that the regulator and any accessories are suitable for the system operating pressure and
temperature and have
suitable connections.
-
At the time of delivery any gauge ports may be plugged with blind fittings. Remove these and connect
gauges if desired.
-
If inlet/outlet fittings are being used, assemble them to the regulator
, per the manufacturer’s instructions,
prior to installing the regulator in the system.
CAUTION
Ensure all upstream tubing/pipework is clean and free from debris. Any swarf, lint, wire, etc. may
damage the regulator, resulting in a seat leak.
-
Verify the flow direction of the system and mount the regulator accordingly.
-
Securely make the appropriate connections to the regulator in accordance with the procedures
recommended by the connection manufacturer.
-
Ensure that the tubing/pipework and the regulator are adequately supported and that there is no stress
on the connections.
-
Upstream and downstream shutoff valves should be installed in the system to facilitate servicing,
maintenance, and troubleshooting of the regulator.
Содержание BSH 10 Series
Страница 10: ...10 BS H Series Exploded View Fig 1 ...
Страница 11: ...11 BS H 10 Series Diaphragm Sensing Section View Fig 2 ...
Страница 12: ...12 BS H 10 Series Piston Sensing with Anti Tamper Section View Fig 3 ...
Страница 13: ...13 BS H 15 Series Diaphragm Sensing Section View Fig 4 ...
Страница 14: ...14 BS H 15 Series Piston Configuration Control Range 5 Fig 5 ...