IMPORTANT. Before commencing maintenance on the shower isolate the hot and cold supplies.
When maintenance is complete ensure the shower valve is checked and fully commissioned before use.

PARTS LIST

1. Fault, After installation shower only runs Hot or Cold and will not mix.

Hot & Cold supplies are plumbed the wrong way around. Remove the thermostatic cartridge, undo the 52mm AF clamp nut 
and pull the cartridge out (use the temperature knob to aid removal) reinstall the thermostatic cartridge with the lug pointing 
away from the hot and cold inlets. 

2. Fault, Shower will not run hot enough when first installed. 

Maximum temperature needs adjusting, see SETTING THE TEMPERATURE

3. Fault, Cold water tracking through the valve into the hot water system.

 Check and clean the non return valve cartridges 

and gauze filters located under the non return valves. (See illustration on Mounting and plumbing stage).

4. Fault, Shower will not run hot when first installed.

 See SETTING THE TEMPERATURE. Check hot water supply from 

boiler is at specified temperature. See IMPORTANT.

5. Fault, Shower only runs cold or lukewarm when first installed.

 Thermostatic cartridge may have debris trapped in the 

cold side. Clean thermostatic cartridge.

6. Fault, Very low flow or no flow (gravity)

. Check Hot & Cold feeds (the valve will shut down if either Hot or Cold supply 

fails). Ensure the correct operation of any flow switches (in pumped applications).

7. Fault, No flow or very low flow (gravity fed installations)

. Very low pressure or blocked filters or pipe work.

8. Fault, No flow or very low flow (pump fed installations).

 Flow rate may be insufficient to activate booster pump flow 

switches, check pump requirements.

9. Fault, Vibration or hammering.

 Dynamic water pressure ratio between hot and cold inlets greater than 5:1 maximum. For 

optimum performance the inlet pressures should be balanced to within 10% of each other. Check for loose pipe work.

10. Fault, Shower will not turn off, turning flow control has no effect.

 Shower may be plumbed to wrong outlet. 

TROUBLE SHOOTING

SB0070

SB0070

SB0082

1178 AF

1178 AF

1595 AF

1595 AF

1595 AF

SB1031

1912

SB0035

SB0103

1298 A SILVER

1397

 

A

 

SILVER

SB0111

SB0073

SB0112

SB0111

SB1035

SB0048

SB1422

1604 AF

SB0086

SB1936

1360 A SILVER

SB0036

SB1029

   

SB0234

SB0087

SB0169

SB0073

SB0073

SB1401

Содержание Brassware

Страница 1: ...ssware co uk SB0309 04 18 Invincible Double controlled outlet concealed valve Installation manual 7209 7200 7200 7209 Before disposing of the carton and commencing installation please check all parts...

Страница 2: ...m set outlet temperatures Please read complete installation instructions before fitting Specification TMV2 valve for use with High and Low Pressure Note 46 C is the maximum mixed water for a bath tap...

Страница 3: ...Pressure 5 0 BAR Fit Pressure reducing Valves above 5 0 BAR Dimensions are approximate due to nature of materials used 235 80 80 250 75 100 125 220 75 BLANKING PLUG OPTIONAL AUXILIARY OUTLET FOR ON OF...

Страница 4: ...PREPARATION x 4 1 PREPARATION 2mm 2 5mm 2mm...

Страница 5: ...75 MAX 105 2 0mm The Inlets and outlets are 3 4 BSP Parallel Threads DO NOT USE TAPER THREADED ADAPTERS OR OVERTIGHTEN ADAPTERS Use appropriate thread sealer Oil based non setting jointing compounds...

Страница 6: ...TILING 5 6 7 2mm 5 62 230 30 6 S I L I C O N E...

Страница 7: ...Measure the mixed water temperature at the outlet Carry out the cold water supply isolation test by isolating the cold water supply to the TMV wait for five seconds if water is still flowing check th...

Страница 8: ...See IMPORTANT 5 Fault Shower only runs cold or lukewarm when first installed Thermostatic cartridge may have debris trapped in the cold side Clean thermostatic cartridge 6 Fault Very low flow or no f...

Отзывы: