background image

Page 12

WALK-IN TUB MANUAL

INSTALLATION INSTRUCTIONS

INST
ALLA

TION  INSTRUCTIONS

5701 NW 35 Avenue Miami, FL 33142 • Phone 866-633-4882 • Fax 866-560-1060

CONNECTING THE AUTO DRAIN

1.  Drain System requires the connection to a minimum 1 ½ sanitary drain line.

2.  Use UPC Approved PVC Glue, primer, and Schedule 40 1 ½ ’ pipe.

3.  Do not change or modify the location and or piping of the Back Flow Preventer.

4.  The sanitary tee is installed directly above the drain tee with clearance not greater than 1’’.

5.  Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit.

6.  Glue the High-Speed Auto drain Fittings, pipe and drain overflow assembly to the sanitary drainage pipe.

7.  Reference figure 2 for connecting auto drain in a soaker or air jetted tub. (page 13)

8.  Reference figure 3 for connecting auto drain in a hydro or dual jetted tub. (page 13)

• 

NOTE: WATER TIGHT INSTALLATION OF THE WASTE/ OVERFLOW IS THE INSTALLER’S RESPONSIBILITY. 
DRAIN LEAKAGE IS EXCLUDED FROM MEDITUB WARRANTY OF THIS PRODUCT.

WARNING:

 WE HAVE TAKEN RESPONSIBLE PRECAUTIONS TO ENSURE THE HIGH-SPEED AUTO DRAIN IS 

SUITABLE FOR RESIDENTIAL PLUMBING. IT IS THE RESPONSIBILITY OF THE INSTALLER TO INSURE THE 
SANITARY SYSTEM IS ACCEPTABLE FOR THE USE OF THE HIGH-SPEED AUTO DRAIN. WE DO NOT ACCEPT 
RESPONSIBILITY FOR DAMAGE ARISING FROM THE USE OF THE HIGH- SPEED AUTO DRAIN.*

*-Ensure compliance with local plumbing codes.

Содержание 2646 Series

Страница 1: ... 2739 2747 2753 2851 2853 2952 2953 3053 3054 3153 3060 3140 3238 3260 3660 FOR MODELS DON T WAIT REGISTER NOW Register your product within 90 days to ensure your bathtub is recognized as an official purchase and is eligible for warranty coverage Mail in the completed registry card Pg 2 or register online at www SWCORP com register MANUAL IS FOR MULTIPLE WALK IN TUB MODELS IMAGE MAY VARY FROM ACTU...

Страница 2: ...nsures we receive your information 2 Complete cut outandmailtheregistrationcardbelow Byreturningthisregistration card we confirm the date of purchase for your new product This confirmation will allow us to process any warranty claims Mail the card to 5701 NW 35 Avenue Miami FL 33142 PRODUCT REGISTRATION Product Registration Card Name Address City State Zip Phone Email Date of Purchase Order or Pur...

Страница 3: ...T 6 PRE INSTALLATION 7 INSTALLATIONPREPARATION 8 ELECTRICALPREPARATION 9 INSTALLATIONPROCEDURES 10 DRAINCONNECTION 11 CONNECTINGTHE AUTODRAIN 12 CONNECTINGDOORDRAIN 14 INSTALLATIONAND EXTENSIONPANELS 15 FAUCETINSTALLATION 16 OPERATINGSAFETY INSTRUCTIONS 17 OPERATINGINSTRUCTIONS 19 TUBCONTROLS 20 CLEANINGANDMAINTENANCE 21 WARRANTY 22 RETURNPOLICY 23 TABLE OF CONTENTS TABLE OF CONTENTS ...

Страница 4: ...Pg 2 orregisteronlineatwww SWCORP com register DOLEVELTHETUB USINGTHE BUILT IN LEVELINGFEETTOPREVENTDOORLEAKAGE Every walk in bathtub comes equipped with adjustable leveling feet THE LEVELING FEET MUST BE ADJUSTED TO ENSURE THE TUB IS LEVELAGAINSTTHEONSITEFLOOR SURFACE FAILURETODOSOMAYRESULTINLEAKAGE DOREPORTANYDEFECTS DAMAGES ORMISSINGITEMSRIGHTAWAY Thoroughly review the bathtub and contents of t...

Страница 5: ... OROTHERINJURIES IMPORTANT SAFETYINSTRUCTIONS INSTRUCTIONSIMPORTANTESRELATIVESALASECURITE READAND FOLLOW ALLINSTRUCTIONS LIREETSUIVRETOUTESLESINSTRUCTIONS SAVETHESE INSTRUCTIONS CONSERVERCESINSTRUCTIONS WARNING RISK OF ACCIDENTAL INJURY OR DROWNING CHILDREN SHOULD NOT USE HYDROMASSAGE BATHTUB WITHOUT ADULT SUPERVISION AVERTISSEMENT RISQUE DE BLESSURE ET DE NOYADE NE PAS LAISSER UN ENFANT UTILISER ...

Страница 6: ...siness days Once the unit is installed surfacedamageswillbeassumedtobeinstallationrelatedifnotreportedatthispoint PLACINGTHEUNIT Pleasenotethataninstaller s assumesfullliabilityfordamagestothewalk inbathtubaftertheunitisinstalledinthe cradle niche WHAT SINSIDE Inside you llshould findthefollowing Model30x53 InstallationInstructions P 1 866 633 4882 www meditub com 100 East Mineola Avenue Valley St...

Страница 7: ...ainedaftertesting Closethedrain andfillthetubuntilitisabovethehighestjet Ifit sasoakerfilluptonormalwaterheightlevel Allowthewater tostandintubfor30minutesandtheninspectallplumbingandsealsforleaks Iftubisjetted supplyelectrictounitandrunfor10minutesandinspectforleaks Inspecttheunionsaroundthepump ifleaks persist from theunionsaftertightening loosentheunionsandinsuretheO ringisseatedproperly NOTE I...

Страница 8: ...imperative that the bathtub s leveling feet are used to ensure the tub itself is perfectlylevel Note itisimportantthatalllevelingfeetarecompletelytouchingthefloorandlevelforthedoor systemtoworkproperly 1 Checkto ensurethatthedrainpipinghasbeen roughed in attheproperlocation 2 Ensure that the proper electrical service has been installed at the pump location See electrical requirements in the manual...

Страница 9: ... circuit NOTE DONOTINSTALLTHEJUNCTIONBOX S WHEREITCANBEREACHEDWHILESITTINGORSTANDINGINTHETUBOR TOUCHING THE FAUCETS AUTODRAIN LIGHTS WHIRLPOOL AIR SPA COMBO HEATER ELECTRICAL REQUIREMENTS This section liststhefactoryinstalledcomponentsoftheJetMassageand orAirMassageSystems Systems Electrical Rating Circuit 1 Dedicated Circuit Soaker w Auto Drain 15 Amp GFCI Soaker w Light 15 Amp GFCI Soaker w Auto...

Страница 10: ...CCESSPANEL FORTHE PUMP MOTOR GENERALGUIDE THROUGH Installtubwaste overflow according to instructions seepage11 After framing is a complete see attached diagrams set product in place to make certain the tub can be properly leveled Caution If a walk in bathtub is not resting on all leveling feet water will not drain properly andmay cause thedoorto leak seepage8 Verify the product s level by checking...

Страница 11: ...eoverflowshouldbeattachedtothe1 pre drilledopeninginthefootwelloftheunit fromthe underside 3 The chrome turn knob and the drain cover should be attached to the appropriate ends of the overflow drain fromthe insideof theunit 4 Place the chromecap with stem into thefloordraintocloseofftheopening 5 The cable attached to the turn knob of the overflow is also connected to a lever inside the floor drain...

Страница 12: ...ue the High Speed Auto drain Fittings pipeanddrainoverflowassemblytothesanitarydrainagepipe 7 Reference figure2 forconnecting auto draininasoakerorairjettedtub page13 8 Reference figure3 forconnecting auto draininahydroordualjettedtub page13 NOTE WATERTIGHTINSTALLATIONOFTHEWASTE OVERFLOWISTHEINSTALLER SRESPONSIBILITY DRAINLEAKAGE IS EXCLUDEDFROM MEDITUBWARRANTYOFTHISPRODUCT WARNING WE HAVE TAKEN R...

Страница 13: ... cable drain cable drain drain shoe sanitary tee drain tee back flow preventer 110V 60hz pump FIGURE 2 SOAKER AIR JET AUTO DRAIN CONNECTION FIGURE 3 HYDRO DUAL JET AUTO DRAIN CONNECTION button on off diverter valve jets overflow drain cable drain cable drain drain shoe sanitary tee drain tee reducer Parts Provided Not Provided back flow preventer 110V 60hz pump Parts Provided Not Provided overflow...

Страница 14: ...in drain Be sure the port is open before attaching the hose Secure the hosewith clampsorties 3 Oncethehoseisinplace closethedoorontheunit placethehandleinthelockedposition andfilltubwithatleast12 ofwater totest theconnection 4 Oncethecompletionofthedraincomponentsareinstalledandhavebeentestedforproperfunction theunitcanbeleveledand giveafinal water testbeforeinstallationofunit Figure4 FIGURE4 Over...

Страница 15: ...STALLATIONANDEXTENSIONPANELS ASSEMBLY PLACEMENT Connect thetwo panelsusingpre drilledholes Inner flange Top panel Side panel Wall Bathroom Waterproof Sheetrock Mortar Tile Silicone Screw 4mm screws not included 2 piece extension panels Molded flange to bolt unit to wall Custom built wall section s for open ends or install against corners of full wall ...

Страница 16: ...sher rubber washer metal washer rubber washer metal washer valve body gasket 3 4 connection connection connection 1 2 3 4 72 shower hose hot water spout diverter cold control handle fixing nut cold water fixing nut valve body valve body local water line not included steel braided 19 hose steel braided 19 hose steel braided 19 hose local water line not included fiber washer metal washer rubber wash...

Страница 17: ... is an increase in body temperature This can be a serious medical condition and all bath users are cautioned against lengthy immersion at high water temperatures Should you become light headed dizzy or nauseous immediatelygetoutofthebathandcooloff Risk of electric shock do not permit electric appliances such as a hair dryer lamp telephone radio or television within four feet of thisbathtub Never d...

Страница 18: ...cating the possibility of an electric shock Do not use this massage bathtub Disconnect the jet massage bathtub and havetheproblem correctedbyaqualifiedservicerepresentativebeforeusing Toreducetheriskofelectricalshock thededicatedelectricalsupplycircuit s mustbegrounded Todothis connectthethirdlegof the 3 conductor wiring cable to the grounding terminal of the electrical service panel and run conti...

Страница 19: ...b isnot in use The pump is operated by the hydro control button which starts the waterflow Theblowerisoperatedbytheaircontrolbuttonwhichstarts the airflow seepage20 Adjustthedirectionandrateofflowofthejetsbymovingthenozzlefordirection Turneithertheoutsideringorthenozzleclockwise orcounterclockwiseforflow somejetsadjusttheflowwiththeoutsideringandsomewiththenozzle Adjusttheairpressureflow ofallwate...

Страница 20: ...mode Continue to press twice to move on to thenextcoloruntilyoufindyourdesiredchoice PRESSONCE whenlightisON Turnsofflight Resetscycle after2secondpause HYDRO JET FLOW CONTROL Used to increase or decrease air pressure flowing through the waterjets FORTUBSWITHWATERJETOPTION FORTUBSWITHAIRJETOPTION FORTUBSWITHCHROMATHERAPYLIGHTOPTION FORTUBSWITHWATERJETOPTION FORTUBSWITH AUTO DRAIN OPTION FORTUBSWIT...

Страница 21: ...tergent such asdishwashingmachinedetergent Turn on whirlpoolsystemandrunfor10minutes Drain tub completely Filltub with coldwaterabovejets Turn on whirlpoolsystemandrunfor15minutes Drain tub completely Cleaningthesuctioncover Cleanandremoveanyhairorlintfromthesuctioncover seeimagebelow Onamonthlybasis unscrewthesuctioncoverandcleanawayanyhair lintordebrisfromthecoverandhousing thenremountthecoverin...

Страница 22: ...nction All labor and repair related services are covered within the first 90 days of purchase This warranty is non transferable and applies only to the original owner as stated on the original purchase order Notification must be sent via certified mail to 5701 NW 35 Avenue Miami FL 33142 The manufacturer will not be responsible for any water damage to any structures or any property for any reason ...

Страница 23: ...lems are not covered by warranty Manufacturer warranties the door seal for the life of the unit under normal use and conditions for the original owner of the tub This warranty shall not apply to any failure resulting from negligence abuse misuse misapplication alternation or medication or improper maintenance Additionally this warranty does not cover discontinued or display products The replacemen...

Страница 24: ...nthewarranty thefollowingproceduresapply Requestsfor returnsand orexchangesmustbemadewithin30daysofreceiptofproduct Theproductmustbein itsoriginal packaging and receivedatourfacilityinsaleablecondition Allreturnswillreceivea20 restockingfeeplusallfreight costs of the originalshipment andreturnshipmenttous Allrequestsfor returnmustfirstbeapprovedbyusandhaveanassignedReturnedMerchandiseAuthorization...

Отзывы: