background image

The design and specifications of this user manual can be changed without any notification to the user. 

All copyright and interpretation rights are reserved to SVT Innovations Inc.

Содержание SVT-MF4 Outdoor Station E

Страница 1: ...SVT MF4 Outdoor Station G User Manual Please read this user manual prior to installing the system and keep it well for future use ...

Страница 2: ...m with two entrances 6 6 Cable Requirements 10 7 User Instructions 11 5 3 SVT 4 Wiring Connection 7 7 1 Visitor calls 11 7 2 Monitor 12 7 3 Intercom 13 4 1 Mounting without the Rain Guard 3 4 2 Mounting with the Rain Guard 4 4 3 Mounting the Indoor Monitor 4 5 3 1 Indoor Station 7 5 3 2 Outdoor Station 7 8 8 How to set up User Codes 14 15 5 3 3 Electric door lock connection 9 ...

Страница 3: ...n Built in microphone Description 1 Built in microphone 2 Monitor button 3 Intercom button 4 Door unlock button 5 Talk button 6 TFT 7 color display 7 Built in speaker 8 Talking Ring volume 9 Brightness 10 Contrast Status light Calling in red light Monitoring Talking blue light 6 Name plate 7 Fingerprint Scanner ...

Страница 4: ... 2 2 Terminal Descriptions ...

Страница 5: ...wer Supply Must be used according to lock Unlocking time 01 99 seconds Communication duration 120s Communication transmission 2 way communication Working temperature 4 F to 131 F 20 C to 55 C INDOOR MONITOR Voltage DC 14 5V Communication duration 120s Communication transmission 2 way communication Working temperature 14 F to 131 F 10 C to 55 C 4 1 MOUNTING WITHOUT THE RAIN GUARD ...

Страница 6: ... 4 Screw anchors Screws Screws fix with rain cover Rain cover Wall hole 4 2 MOUNTING WITH THE RAIN GUARD 4 3 MOUNTING THE INDOOR MONITOR ...

Страница 7: ... 5 5 1 SVT MF4 SYSTEM WITH ONE ENTRANCE System Wiring and Connections 5 ...

Страница 8: ... 6 5 2 SVT MF4 SYSTEM WITH TWO ENTRANCES ...

Страница 9: ... supply is compatible with the door lock specifications The J3 output is also DRY contact NO COM NC CN10 Must remain connected to J1 port on the upper module CN22 Reserved port JP1 Remove the black jumper if a access control unit is connected to the outdoor station SVT 3100 SVT 4100 SVT 5100 Access Control System only J1 Connect the access control unit SVT 3100 SVT 4100 SVT 5100 Access Control Sys...

Страница 10: ... 8 ...

Страница 11: ...tion 1 Use the port J3 of the lower module to connect a door lock 2 The door lock is limited to 14 5V 120mA 3 Must use an additional power supply for the door lock Ensure the power supply is compatible with the door lock specifications ...

Страница 12: ... reach 230 feet 70 meters 30 feet 10 meters NOTE 1 The system expands to a maximum of 2 outdoor stations and 4 indoor monitors 2 Each indoor monitor requires its own power supply 14 5V 1 3A 3 We recommend soldering the wires together to ensure a good connection Do not use wire nuts 10 4 For long runs typically longer then 90ft we recommend using coax cable for the video function ...

Страница 13: ... shown on the monitor 7 1 Visitor calls Check After pressing the unlocked button the indoor monitor still displays the image from the front door camera End the call Talk begins Open the lock The talk time is up to 2 minutes Press the TALK button or hang up the handset The visitor presses the call button on outdoor station 1 Ring Ring The visitor presses the call button on outdoor station 2 7 User ...

Страница 14: ...ain indoor monitor to extension indoor monitor Any indoor monitor press button or pick up the handset to talk with the outdoor station Press twice Press once The indicator light of Door 1 is on The indicator light of Door 2 is on End the monitor Press the monitor button Monitor outdoor station 1 Monitor outdoor station 2 Press the talk button Press the talk button Monitor the outdoor station Press...

Страница 15: ...button or hang upbutton or hang up the handsetthe handset Talk begins Any indoor monitor presses button or pickup the handsetto talk 7 3 Intercom In the standby mode press intercom button in any indoor monitor During the talking any indoor monitor presses the intercom button ...

Страница 16: ... batteries Sensor working distance 20cm Modify administrator code Enter the setting mode Input the admin default code twice 1234 1234 the yellow LED will be on It is in the setting mode The default code is 1234 In the setting mode Press 3 Yellow light blinks and then enter a new administrator code XXXX twice If Bi is heard it means the operation is successful Press to exit the setting mode Notice ...

Страница 17: ...essful Press to exit the setting mode In the setting mode Press 000 899 Yellow light blinks If red light is on it indicates the position is occupied Press twice to delete the information in this position and then add the fingerprint If green light is on it indicates the position is vacant Fingerprint can be added put the finger on the scanner until a Bi sound is heard Then another Bi and Bi will b...

Страница 18: ... enter security level number twice Parameter range is 1 2 3 4 5 The higher number indicates the higher accuracy of fingerprint recognition If Bi is heard it indicates the setting is successful If Bi Bi Bi are heard it indicates the setting fails Press to exit the setting mode ...

Страница 19: ......

Страница 20: ...The design and specifications of this user manual can be changed without any notification to the user All copyright and interpretation rights are reserved to SVT Innovations Inc ...

Отзывы: