![Svpribor Irk-Pro gamma Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/svpribor/irk-pro-gamma/irk-pro-gamma_instruction-manual_1410758011.webp)
11
TRACE VIEWING
Linear scale
There are two cursors on the TDR screen, between them the distance is measured on the trace.
To make a cursor an active – press the
◄►
keys. To vertical move a trace – press the
▲▼
key.
To operate with the trace gauges use the following keys: [PULSE], [RANGE],
[AMPLIFICATION]. At setting the viewing range the device select itself the measuring pulse
width. The [STRETCHING] key is used to view the detail trace around an active cursor. The
[MAP] key is used to view the whole cable. The [AVERAGING] key is used to eliminate the
occasional noises and to rice picture stability during the averaging increasing.
The keys on the left vertical part of the menu are changing the TDR working mode: trace
recording [trace memory], activation of the logged trace for the comparison [+ memory]; work
in separate or combined mode; adjusted pulse amplitude, the mode of averaging for a line with
intensive noise.
The keys on the left vertical part of the menu:
Trace recording [trace memory];
activation of the logged trace for the comparison [+ memory];
work in separate or combined mode;
selection of the match resistance;
selection of the scale (linear, logarithmic, pseudologarithmic)