background image

3. PACKAGE CONTENTS

 Uninterruptible power supply — 1 pc

 Interface cable to connect external batteries — 2 pcs

 Operation manual — 1 pc

 Warranty card — 1 pc

4. TECHNICAL DESCRIPTION 

Operating principle

 Models of RESERVE HOME series fall in the line-interactive uninterruptible power supply of 

continuous action with prolonged back-up time. Principle of their operation is based on the 

transformation of direct current of external batteries to alternating current. Current waveform at 

the output is the regular sine curve.

 Its primary function is the power supply for household and industrial equipment, which is 

critical to the input current waveform (boiler equipment, automation systems, etc.). 

 The device is equipped with the automatic voltage regulator (AVR). The built-in regulator 

allows providing correct power supply of load at overvoltage/undervoltage of the mains without 

going to the operation mode from batteries.

 The intellectual circuit of battery charging is used in the device, which automatically selects 

the charging mode.

 The automatic start function provides automatic switching on when there is power supply. 

With input voltages 160 V and 260 V the automatic start is not activated.

Special features

 Continuous action with prolonged back-up time

 Built-in automatic voltage regulator

 Regular sinusoidal output signal

 Microprocessor control

 Intellectual charger for connected external batteries

 Protection against short circuit in connected load to UPS, as well as against overload

 Protection against overvoltage or undervoltage in the mains 

 IP-20 ingress protection

 Self-diagnosis after switching on

 Indication of operation modes on LCD display

 Mode switchover time 

 5 msec

 Automatic start function

 Low noise level

ENG

3

Operation Manual

Reserve

Home

Содержание Reserve Home

Страница 1: ...www sven fi OPERATION MANUAL Reserve Home Uninterruptible Power Supply...

Страница 2: ...e device carefully Make sure there are no accessories left in the box Check up the device for damage if the product was damaged during transportation address the firm which carried out the delivery if...

Страница 3: ...ric shock In case of an emergency turn o the UPS and disconnect the power cord from the mains It is strictly prohibited to open the device case there is high voltage inside In case of any problems con...

Страница 4: ...providing correct power supply of load at overvoltage undervoltage of the mains without going to the operation mode from batteries The intellectual circuit of battery charging is used in the device wh...

Страница 5: ...its value goes beyond its rate g CHECK error indicator h UPS on o button i OVERLOAD overload indicator j buzzer on o button k RS232 RS232 connector l AC Input power cord m Circuit Breaker automatic te...

Страница 6: ...on the five segment indicator c every segment displays approx 20 of the battery capacity When the battery is charged completely approx 12 hours all 5 segments of the indicator c must light When the b...

Страница 7: ...ns in premises where the device placement is intended must correspond to the norms indicated in the Technical Specifications table The UPS must be stored with batteries full charged Storage conditions...

Страница 8: ...teries are discharged greatly 2 Defective batteries 3 Circuit of connecting cables of batteries is open Solution 1 Switch on the switch 2 Switch o the load Press the fuse button If the UPS operation i...

Страница 9: ...ode Output waveform Protection Cooling type Beeps Switching time msec Battery plug in external optional Temperature conditions Storage temperature Humidity Noise level dB Dimensions W H D mm Weight kg...

Страница 10: ...ve Home 500 800 1000 111024 65 1 105082 75 5 www sven fi 24 5 176 02 02 427447 48310 15 Manufacturer SVEN PTE LTD 176 Joo Chiat Road 02 02 Singapore 427447 Produced under the control of Oy Sven Scandi...