Svantek SVAN 958 Скачать руководство пользователя страница 3

                                                                                                                             SVAN 958 USER MANUAL

 

i

CONTENTS 

1

INTRODUCTION 

1-1

1.1 SVAN 958 as Sound Level Meter & Analyser 

1-1

1.2 SVAN 958 as Vibration Meter & Analyser 

1-2

1.3 General features of SVAN 958 

1-2

1.4 Accessories included 

1-3

1.5 Accessories available 

1-3

2

MANUAL CONTROL OF THE INSTRUMENT 

2-1

2.1 Control push-buttons on the front panel 

2-1

2.2 Input and output sockets of the instrument 

2-6

3

SETTING THE INSTRUMENT 

3-1

3.1 Basis of the instrument’s control 

3-1

3.2 Powering of the instrument 

3-25

3.3 Initial setup of the instrument 

3-27

3.4 Activation of optional functions 

3-32

3.5 Memory organisation 

3-33

4

FUNCTIONS OF THE INSTRUMENT - FUNCTION 

4-1

4.1 Measurement functions of the instrument - MEASUREMENT FUNCTION 

4-1

4.2 Instrument’s calibration - CALIBRATION 

4-2

4.2.1 Calibration by the sensitivity introduction 

4-2

4.2.2 Calibration by the measurement 

4-5

4.2.3 View on the last calibration result - CALIBRATION HISTORY 

4-8

5

MEASUREMENT PARAMETERS SETTING - INPUT 

5-1

5.1 Selection of measurement parameters - MEASUREMENT SETUP 

5-2

5.1.1 Setting time delay before the start of measurements - START DELAY 

5-2

5.1.2 Setting integration period - INT. PERIOD 

5-3

5.1.3 Setting the number of repetition of measurement cycles - CYCLES NUMBER 

5-4

5.1.4 Setting time period between two writings to the logger’s file - LOGGER STEP 

5-4

5.2 Setting parameters in channels - CHANNELS SETUP 

5-6

5.2.1 Selection of measurement mode for sound or vibration - MODE 

5-6

5.2.2 Measurement range setting - RANGE 

5-7

5.2.3 Weighting filter selection in a profile - FILTER 

5-7

5.2.4 RMS detector selection - DETECTOR 

5-9

5.2.5 Setting the parameters of microphone (SM) - MICROPHONE CORRECTION 

5-9

5.3 Results selection for saving in a logger’s file - LOGGER SETUP 

5-10

5.3.1 Selecting results to be saved in instrument’s logger memory - LOGGER MODE 

5-10

5.3.2 Selecting time-history results to be saved in the memory - LOGGER MODE: ON  5-10

5.3.3 Selecting parameters of low sampling rate time-domain signal recording (svn 

format) in memory of the instrument - LOGGER MODE: TIME 

5-11

Содержание SVAN 958

Страница 1: ...TRUMENTATION FOR SOUND VIBRATION MEASUREMENTS AND ANALYSIS SVAN 958 FOUR CHANNELS SOUND VIBRATION LEVEL METER ANALYSER draft version USER S MANUAL USER S MANUAL USER S MANUAL USER S MANUAL SVANTEK Sp...

Страница 2: ...ts the software revision named 3 01 0 3 05 1 cf the description of the UNIT LABEL path MENU DISPLAY UNIT LABEL The succeeding software revisions marked with the bigger numbers can slightly change the...

Страница 3: ...ORY 4 8 5 MEASUREMENT PARAMETERS SETTING INPUT 5 1 5 1 Selection of measurement parameters MEASUREMENT SETUP 5 2 5 1 1 Setting time delay before the start of measurements START DELAY 5 2 5 1 2 Setting...

Страница 4: ...meters for dose measurements HAV WBV DOSE SETUP 5 21 5 5 4 1 Enabling HAV WBV settings ENABLED 5 21 5 5 4 2 Setting the time of exposure EXPOSURE TIME 5 22 5 5 4 3 Selection of channels for HAV WBV DO...

Страница 5: ...t s memory SAVE OPTIONS 7 5 7 2 1 Saving files in RAM memory RAM FILE 7 6 7 2 2 Controlling of the measurement statistics savings SAVE STATISTICS 7 6 7 2 3 Saving minimum values in the spectrum MIN SP...

Страница 6: ...UP 8 12 8 13 1Selecting the mode for introduction of user filter coefficients MODE 8 13 8 13 2Selecting the filter to be viewed edited or cleared FILTER 8 13 8 13 3Setting the coefficients of the user...

Страница 7: ...UT list in RT 60 mode 3 9 Control diagram of INPUT list 3 11 Control diagram of DISPLAY list 3 14 Control diagram of DISPLAY list in 1 1 OCTAVE and 1 3 OCTAVE analysis of vibration 3 14 Control diagra...

Страница 8: ...ration result by pressing the ENTER push button 4 7 CALIBRATION window with CALIBRATION HISTORY text selected a CALIBRATION HISTORY window opened with the last calibration result b 4 8 CALIBRATION HIS...

Страница 9: ...ATION selection with 10 units step 5 17 RPM SETUP window the UNIT selection 5 17 RPM SETUP windows with LOGGER activation 5 18 AUXILIARY SETUP window with SEAT SETUP text highlighted 5 18 Selection of...

Страница 10: ...with DISPLAY SCALE text highlighted 6 4 Displays with the possible options of the SCALE in vibration mode 6 4 Displays with the possible values of the vertical axis in LOGGER and SPECTRUM presentatio...

Страница 11: ...7 12 DELETE windows with the selection of the file to be deleted 7 12 Execution of DELETE operation 7 12 Execution of the 02JAN5 file deletion and the influence of this process on the memory space 7 1...

Страница 12: ...of displacement signal 8 8 REFERENCE LEVELS window with the reference level of the acoustic signal 8 8 SETUP list with RMS INTEGRATION text highlighted displayed inversely 8 8 Displays with the availa...

Страница 13: ...les 9 5 WBV CALCULATOR window 9 5 WBV CALCULATOR window with SELECT RESULTS text highlighted displayed inversely 9 6 Displays in the SELECT RESULTS list 9 6 SELECT FILE windows with the selection of t...

Отзывы: