SVAN 948 USER MANUAL
.
3 - 22
-
“
Vertical bars
” icon corresponds to the current
input signal level
(it is related to the maximum
measured value over the last second). The sign
Ç
Ç
Ç
Ç
means that the level of the signal was from 0.1 dB to
10 dB higher then the current measurement range. For example, for the
SLM
mode, in which only one
range is available (130 dB), the result of the measurement is in this case from 130.1 dB to 140 dB. The
indicator of the overload (the
”Bell”
icon) appears when the signal overpasses more than 7.5 dB the
measurement range (cf. Fig. below).
a)
b)
c)
d)
e)
g)
h)
i)
The view of the display in the SLM mode without the “Vertical bars” icon (a); with one “Vertical bar” (b),
(c); with two “Vertical bars” (d), (e); with three “Vertical bars” (f), (g); with three “Vertical bars” and the
Ç
Ç
Ç
Ç
sign (h); with the indicator of the overload (i)
The number of the
”Vertical bars”
on the display depends on the level of the measured signal, the
selected mode (
SLM
,
VLM
,
1/1 OCTAVE
,
1/3 OCTAVE
or
FFT
analysis, etc) and the calibration factor.
The limits of the signal causing the different icon’s indication for the calibration factor equal to 0 dB are
presented in the Table 3.1 in the case of sound measurements and in Table 3.2 – in the case of vibration
measurements. Non-zero value of this factor causes the shift of the limits given in the tables.
Notice: The “Bell” icon is used as an indicator of an overload
.
In the case when the level of the measured signal is too low
in the relation to the measuring
range (when the level of the input signal is under the linearity of the range declared in App. C, so-called
UNDERRANGE
) in one profile mode the message is displayed in the field of the analogue indicator of the
measurement result. The arrow directed down is used for this reason in
3 PROFILES
mode.
Notice:
The
UNDERRANGE
is indicated only in the case of sound measurements. It does
not occur in the case of vibration measurements.
The view of the displays when the level of the signal is too low during the measurements of the sound
Содержание SVAN 948
Страница 1: ...SVAN 948 SOUND AND VIBRATION DATA LOGGER USER S MANUAL SVANTEK Sp z o o WARSAW June 2004...
Страница 19: ...SVAN 948 USER MANUAL 2 6 The view of the rear panel of the SVAN 948 instrument in 1 1 scale...
Страница 25: ...SVAN 948 USER MANUAL 3 6 Control diagram of the INPUT list...
Страница 28: ...SVAN 948 USER MANUAL 3 9 Control diagram of the DISPLAY list...
Страница 30: ...SVAN 948 USER MANUAL 3 11 Control diagram of the FILE list...
Страница 32: ...SVAN 948 USER MANUAL 3 13 Control diagram of the AUX FUNCTION list...
Страница 36: ...SVAN 948 USER MANUAL 3 17...
Страница 37: ...SVAN 948 USER MANUAL 3 18 Control diagram of the SETUP list...