Charging System: 1J-1
Engine
Charging System
Schematic and Routing Diagram
Charging System Diagram
B822H11A02001
Component Location
Charging System Components Location
B822H11A03001
Refer to “Electrical Components Location in Section 0A (Page 0A-7)”.
Diagnostic Information and Procedures
Charging System Symptom Diagnosis
B822H11A04001
SCR
IC
Generator
Regulator/Rectifier
Ignition switch
Batter
y
Load
I718H11A0001-01
Condition
Possible cause
Correction / Reference Item
Generator does not
charge
Open- or short-circuited lead wires, or
loose lead connections.
Repair, replace or connect properly.
Short-circuited, grounded or open
generator coil.
Replace.
Short-circuited or punctured regulator/
rectifier.
Replace.
Generator does charge,
but charging rate is below
the specification
Lead wires tend to get short- or open-
circuited or loosely connected at
terminals.
Repair or retighten.
Grounded or open-circuited generator
coil.
Replace.
Defective regulator/rectifier.
Replace.
Defective cell plates in the battery.
Replace the battery.
Generator overcharges
Internal short-circuit in the battery.
Replace the battery.
Damaged or defective regulator/rectifier.
Replace.
Poorly grounded regulator/rectifier.
Clean and tighten ground connection.
Unstable charging
Lead wire insulation frayed due to
vibration, resulting in intermittent short-
circuiting.
Repair or replace.
Internally short-circuited generator.
Replace.
Defective regulator/rectifier.
Replace.
Содержание VLR1800
Страница 4: ......
Страница 64: ...0C 12 Service Data...
Страница 456: ...2D 22 Wheels and Tires...
Страница 489: ...Drive Chain Drive Train Drive Shaft 3A 31 09951 17010 Bearing installer Page 3A 19...
Страница 490: ...3A 32 Drive Chain Drive Train Drive Shaft...
Страница 580: ...6B 11 Steering Handlebar...
Страница 623: ...Prepared by January 2008 Part No 99500 39360 01E Printed in Japan 624...