Disassembly and Assembly
13
013447-101_rev-07
SC 303/313
SCAN COIN
7.2
Plastic Covers
To gain access to the main body of the machine for adjustment or
exchange of parts the plastic covers must be removed.
a) Remove the plastic cover (2) from the right hand side of the
machine.
b) Loosen and remove the screw on the right near the sensor and
then lift off the top left plastic cover (1).
c) Loosen and remove the two screws securing the top coin tray and
top back cover.
d) Lift off the coin tray and top back cover.
e) Carefully turn the machine upside down.
f) Loosen and remove the four fixing screws securing the lower
cover to the main body.
g) Carefully turn the machine back the right way up.
h) Unplug the power connector located at the motor assembly.
i) Lift the main body out of the lower cover.
Q
M ACC
ON/OFF
B CE
MOTOR
SCAN COIN
303
COIN COUNTER
1
2
1 Left plastic cover
2 Right plastic cover