background image

6

1. FOR YOUR SAFETY

Always remember that THE DIVER IS RESPONSIBLE FOR HIS OR HER OWN
SAFETY!

When used properly the SOLUTION

 á

 is an outstanding tool for assisting properly

trained, certified divers in planning and executing standard and multi-level sport
dives within the described no-decompression limits. It is NOT A SUBSTITUTE FOR
CERTIFIED SCUBA INSTRUCTION including training in the principles of
decompression.

DO NOT attempt to use the Suunto SOLUTION

 á

 without reading this entire

Instruction Manual. If you have any questions about the manual or the SOLUTION

á

, contact your Suunto dealer before diving with the SOLUTION

 á

.

Back-Up Instruments

WARNING!
USE BACK-UP INSTRUMENTS!
Make certain that you use back-up instrumentation including a depth gauge,
submersible pressure gauge, timer or watch, and have access to decompression
tables  whenever diving with the SOLUTION

 á

.

Sharing the SOLUTION

 á

WARNING!
THE SOLUTION

 á

 SHOULD NEVER BE TRADED OR SHARED BETWEEN

USERS WHILE IT IS IN OPERATION!
Its information will not apply to someone who has not been wearing it throughout a
dive or sequence of repetitive dives. Its dive profiles must match that of the user. If it
is left on the surface during any dive, it will give inaccurate information for
subsequent dives.

No dive computer can take into account dives made without the computer. Thus any
diving activity 48 hours prior to initial use of the computer may give misleading
information and must be avoided.

High Altitude/ Personal Adjustment

More information about this is given in Section 3.5, "High Altitude Dives and
Personal Adjustment".

Содержание Solution Alpha

Страница 1: ...n serious injury or death CAUTION is used in connection with a procedure or situation that will result in damage to the product NOTE is used to emphasize important information WARNING READ THIS MANUAL Carefully read this instruction manual in its entirety including Section 1 For Your Safety Make sure that you fully understand the use displays and limitations of the SOLUTION á WARNING NO DIVE COMPU...

Страница 2: ...sk of decompression sickness Therefore Suunto specifically recommends that the SOLUTION á be not used for commercial or other severe diving activity WARNING PERFORM PRECHECKS Always check the SOLUTION á before diving in order to ensure that all LCD segments are completely displayed that the SOLUTION á has not run out of battery power and that the altitude personal adjustment mode is correct WARNIN...

Страница 3: ...Data 3 3 2 Ascent Meter 3 3 3 Audible and Visual Alarms 3 3 4 Decompression Dives 3 4 AT SURFACE 3 4 1 Surface Interval 3 4 2 Flying After Diving 3 5 HIGH ALTITUDE DIVES AND PERSONAL ADJUSTMENT 3 6 ERROR CONDITIONS 4 MENU BASED MODES 4 1 LOGBOOK AND DIVE PROFILE MEMORY 4 2 DIVE HISTORY MEMORY 4 3 ALTITUDE PERSONAL ADJUSTMENT SETTING 4 4 DIVE SIMULATOR 4 5 SETTING TIME AND DATE 5 PC INTERFACE 6 CAR...

Страница 4: ...es and dive simulation The instrument can be adjusted for diving at different altitudes or to add an extra level of conservativeness if desired The screen is protected against scratches and damage by a replaceable shield The SOLUTION á is available either as a wrist unit or mounted in two gauge or three gauge console or in a hose mounted boot The modular construction allows for the separate compas...

Страница 5: ...ial units are shown in brackets The SOLUTION á is also available with imperial units i e feet and F WARNING VERIFY THAT THE UNITS OF MEASURE WHETHER METRIC OR IMPERIAL ARE CORRECT BEFORE STARTING TO DIVE Any confusion resulting from improper selection of units may cause the diver to commit errors that may lead to serious injury ...

Страница 6: ...in that you use back up instrumentation including a depth gauge submersible pressure gauge timer or watch and have access to decompression tables whenever diving with the SOLUTION á Sharing the SOLUTION á WARNING THE SOLUTION á SHOULD NEVER BE TRADED OR SHARED BETWEEN USERS WHILE IT IS IN OPERATION Its information will not apply to someone who has not been wearing it throughout a dive or sequence ...

Страница 7: ...tude limit of the SOLUTION á exceeds or is equal to the altitude of the dive site The altitude mode indicator must show either A1 or A2 depending on the altitude More information about this is given in Section 3 5 High Altitude Dives and Personal Adjustment Decompression Dives WARNING DO NOT USE THIS INSTRUMENT TO CONDUCT DECOMPRESSION DIVES Suunto does not recommend this instrument to be used to ...

Страница 8: ...of DCS increases when depth and the number of repetitive dives increase and when the surface intervals are decreased MULTIDAY DIVES repetitive dives performed for several consecutive days DECOMPRESSION DIVES any dive during which the no decompression limit has been exceeded or the diver is advised by the computer that he may not return directly to the surface WARNING DIVE PRACTICES WHICH INCLUDE T...

Страница 9: ...heir diving activities Suunto supports these practices and strongly recommends that the diver make the deepest portion of the dive near the beginning of the dive and gradually progress into shallower depth allowing time for a 3 to 5 minutes safety stop at a depth range of 3 to 6 meters 10 to 20 ft This is believed to be effective in further reducing the risk of decompression sickness Furthermore t...

Страница 10: ...d dive planning contact TIME MODE time display and mode selection contact On the surface the SOLUTION á is operated by simultaneously touching the COM contact and one or two of the other contacts When doing this your finger tips should be wet or moist to establish the necessary electric contact When submerged these contacts are automatically connected by the conductivity of the water 2 2 ACTIVATIO...

Страница 11: ...DIVE PLANNING display will rapidly cycle through the no decompression limits for various depths Diving simulation To simulate a dive use the three contacts as follows To descend touch the ON PLAN and COM contacts for as long as you want to descend To ascend touch the TIME MODE and COM contacts You will have to lift your fingers momentarily to avoid an excessive ascent speed rate We are now ready t...

Страница 12: ...his is most easily done by first covering the TIME MODE and ON PLAN contacts with your right thumb and then touching the COM contact with your left thumb As usual it helps if your fingers are wet or moist This procedure will bring you back to the normal READY mode The SOLUTION á is now ready for a dive It will automatically switch off in about 10 minutes of surface time in case you do not use it a...

Страница 13: ... CONTACTS As described in Section 2 1 Water Contacts the SOLUTION á is controlled with the COM common ON PLAN and TIME MODE contacts as follows Activation touch the ON PLAN and COM contacts Dive planning once the SOLUTION á has been activated touch the ON PLAN and COM contacts Clock touch the TIME MODE and COM contacts for a second The time is then displayed for four seconds When the TIME MODE and...

Страница 14: ...ed However it is necessary to turn it on before diving to check the altitude personal adjustment setting battery warning etc This is done either by immersing it in water for a couple of seconds or by connecting the ON PLAN and COM contacts with fingertips A short beep is heard All display elements will turn on showing mostly figure 8 s and graphical elements A few seconds later the serial number o...

Страница 15: ...ection 3 5 High Altitude Dives and Personal Adjustment Battery warning If the battery symbol is displayed the SOLUTION á should not be used It indicates that the battery is too low to operate the SOLUTION á If the low battery symbol appears during a dive you should abort the dive and begin ascent to the surface NOTE Temperature affects the battery voltage If the SOLUTION á is stored at temperature...

Страница 16: ...n on the display is clearly marked During a no decompression dive the following information will be shown the available no decompression time in minutes is shown as NO DEC TIME It is calculated based on the five factors listed in Section 7 1 OPERATING PRINCIPLES your present depth is shown in meters ft In addition to the digital display the present depth is also displayed graphically with a depth ...

Страница 17: ...p at this depth and wait until the warning disappears WARNING RAPID ASCENTS INCREASE THE RISK OF INJURY Do not exceed the maximum recommended ascent rate You must never surface with the SLOW warning on If you do this the warning will continue to flash until the unit deactivates itself in the normal manner This may take up to 48 hours WARNING DO NOT ATTEMPT TO DIVE FOLLOWING A SURFACE INTERVAL DURI...

Страница 18: ... Er appears You should immediately descend to or below the ceiling The SOLUTION á will otherwise enter a permanent error mode in three minutes indicated by a non blinking Er 3 3 4 Decompression dives WARNING DO NOT USE THIS INSTRUMENT TO CONDUCT DECOMPRESSION DIVES Suunto does not recommend this instrument to be used to conduct decompression dives However if through carelessness or emergency a div...

Страница 19: ...rder to avoid doing so by accident you should stay slightly below the ceiling Ceiling Floor and Decompression Range When in decompression it is important that you understand the meaning of ceiling floor and decompression range The ceiling is the shallowest depth to which you should ascend when in decompression At this depth or below you must perform one or several decompression stops All decompres...

Страница 20: ...art your ascent immediately Display Above Floor When you ascend above the floor the ASC TIME display stops blinking and the two upward pointing arrows disappear Decompression will now begin but is very slow You should therefore continue your ascent Display At Ceiling When you reach the ceiling the display will show you two arrows pointing toward each other Do not ascend above this depth As describ...

Страница 21: ... The temperature in C F is shown in the lower left corner The no flying warning is indicated by a blinking airplane The desaturation no flying time in hours and minutes is shown next to the non blinking airplane in the center window of the display If you start a new dive in less than 10 minutes at the surface the SOLUTION á interprets this as a continuation of the previous dive The DIVING display ...

Страница 22: ...mmercial jetliner altitude up to 2400 m 8000 ft Divers who plan to make daily multiple dives for several days or make dives that require decompression stops should take special precautions and wait for an extended interval beyond 12 hours before flight Suunto recommends that flying be avoided until both the DAN guidelines and the SOLUTION á wait to fly conditions are satisfied 3 5 HIGH ALTITUDE DI...

Страница 23: ...ginning to dive at altitude WARNING DO NOT USE THIS INSTRUMENT TO CONDUCT DECOMPRESSION DIVES Suunto does not recommend this instrument to be used to conduct decompression dives However if through carelessness or emergency a diver is forced to exceed the no decompression limits on a dive the SOLUTION á will provide decompression information required for ascent After this the SOLUTION á will contin...

Страница 24: ...tinue to function normally if the diver descends below the ceiling within three minutes After this the SOLUTION á will enter a permanent ERROR MODE In the permanent ERROR MODE the SOLUTION á will not show no decompression or ascent times Only a permanent Er warning is shown in the center window However all the other displays will function as before to provide information for ascent At the surface ...

Страница 25: ...25 to very low battery poor battery contacts or leakage to the battery compartment ...

Страница 26: ...bar segment on the right hand side of the display will indicate the scrolling sequence Note that the menu based modes can be activated only when 10 minutes have elapsed after the dive Make sure that the contacts and the instrument itself are dry and clean before trying to use the menu based modes All menu based modes can be deactivated by the RETURN command i e by connecting all three contacts sim...

Страница 27: ... The memory will always retain approximately the last 25 hours of dive time The contents of the memory will remain even when the battery is changed assuming that the replacement has been done according to the instructions Dive Profile Memory The detailed profile of each dive shown in the logbook at that moment is accessed by touching the ON PLAN and COM contacts Two LCD bar segments in the upper r...

Страница 28: ...RY The Dive History is activated by touching the TIME MODE and COM contacts until HIS appears This mode will show the maximum depth ever reached the total accumulated dive time in hours the total number of dives 999 dives and 999 hours of diving can be registered When these maximum values are reached the counters will start again from 0 4 3 ALTITUDE PERSONAL ADJUSTMENT SETTING The current altitude...

Страница 29: ... SOLUTION á will return to the surface mode WARNING ALWAYS RECHECK THE ALTITUDE PERSONAL ADJUSTMENT SETTING TO ENSURE THAT IT IS NOT SET FOR AN ALTITUDE LESS THAN THAT OF THE DIVE SITE 4 4 DIVE SIMULATOR The simulation mode can be used to plan dives in advance for demonstrational or educational purposes or just for pleasure The SOLUTION á has complete dive simulating capabilities including repetit...

Страница 30: ...de separately for both digits as shown by the blinking digit In case of the hours and month the complete number is changed simultaneously 4 Repeat steps 3 and 2 to change any additional values 5 Restart the clock with the RETURN command i e by connecting all three contacts at the same time First make contact between the ON PLAN and TIME MODE contacts and after that with the COM contact If somethin...

Страница 31: ...ON á The following data is transferred to the PC depth profile of the dive dive time dive number altitude personal adjustment setting temperature at maximum depth surface interval time dive entry time year month day and time additional dive information e g violations serial number It is also possible to manually add comments and other personal information to the PC based dive data file ...

Страница 32: ...he battery replacement The service requires special tools and training Therefore it is advisable to contact an authorized Suunto dealer for biennial service Do not attempt to do any service that you are not sure about how to do The SOLUTION á will display a battery symbol as a warning when the power gets too low When this happens the SOLUTION á should not be used until the battery has been replace...

Страница 33: ...sed air to blow water off the unit do not use solvents or other cleaning fluids that might cause damage do not test or use the SOLUTION á in pressurized air 6 2 BATTERY COMPARTMENT INSPECTION Frequently check for leaks in the battery compartment This is important specially after the battery replacement If you find moisture inside the transparent battery compartment lid there is a leak A leak must ...

Страница 34: ...TIRE OWNER S MANUAL The SOLUTION á must be activated before diving and operated correctly to provide accurate and correct information No Decompression Limits The no decompression limits displayed by the SOLUTION á upon activation are for most dives to a single depth slightly more conservative than those permitted by the U S Navy tables Tables 7 1 2 TABLE 7 1 NO DECOMPRESSION TIME LIMITS min FOR VA...

Страница 35: ...ch longer than those that would be allowed by the U S Navy tables WARNING THE USER SHOULD BE AWARE THAT ANY DIVE INCLUDING ONES WITHIN THE U S NAVY OR SOLUTION á LIMITS DOES CARRY SOME RISK OF DECOMPRESSION SICKNESS Compartments and Half Times When you dive with the SOLUTION á it measures and displays depths and times as your dive progresses It shows you available no decompression time and possibl...

Страница 36: ...ompartments for all phases of diving including surface intervals and repetitive dives The SOLUTION á s half times range from 2 5 to 480 minutes Altitude Diving The atmospheric pressure is lower at high altitudes than at sea level After traveling to a higher altitude the diver will have additional nitrogen in his body compared to the equilibrium situation at the original altitude This additional ni...

Страница 37: ... fresh water the readings are about 3 smaller Depth display range 0 to 99 m 325 ft Accuracy 1 0 to 60 m 200 ft Resolution 0 1 m 1 ft Temperature display Resolution 1 C 1 5 F Display range 20 50 C 40 122 F Accuracy 2 C 3 6 F within 20 minutes of temperature change Calendar Clock Accuracy 2 s 24 h 24 h display 12 h display in imperial version Other displays Dive time 0 to 999 min Surface time 0 to 4...

Страница 38: ...oom temperature NOTE Do not leave the SOLUTION á in direct sunlight Battery One 3 6 V lithium battery Saft LS 14250 size 1 2 AA ANSI or 1 2 R6 IEC spare part number K5504 O ring 26 7 mm x 1 78 mm 70 ShA spare part number K5508 Battery life typically 2000 hours at 20 C 68 F ...

Страница 39: ...no charge and returned in what your Suunto Dealer determines a reasonable amount of time provided all necessary parts are in stock All repairs made not covered under the terms of this warranty will be made at the owner s expense This warranty is non transferable from the original owner All implied warranties including but not limited to the implied warranties of merchantability and fitness for a p...

Страница 40: ... which a diver must stop for some time during ascent Decompression sickness Any of a variety of maladies resulting either primarily or secondary from the formation of nitrogen bubbles in tissues or body fluids as a result of inadequately controlled decompression Commonly called bends or DCS Dive series A group of repetitive dives between which the SOLUTION á indicates some nitrogen loading is pres...

Страница 41: ...t any time NO DEC TIME Abbreviation for no decompression time limit Repetitive dive Any dive whose no decompression time limits are affected by residual nitrogen absorbed during previous dives Residual nitrogen The amount of excess nitrogen remaining in a diver after one or more dives SURF TIME Abbreviation for surface interval time Surface interval time Elapsed time between surfacing from a dive ...