6
WARNING
Do not dive with a cylinder of enriched air if you have not personally verifi ed
its contents and entered the analyzed value into your dive computer. Failure to
verify cylinder contents and enter the appropriate O
2
% into your dive computer
will result in incorrect dive planning information.
WARNING
The dive computer will not accept fractional percentage values of oxygen
concentration. Do not round up fractional percentages. For example, 31.8%
oxygen should be entered as 31%. Rounding up will cause nitrogen percentages
to be understated and will affect decompression calculations. If there is a
desire to adjust the computer to provide more conservative calculations, use
the personal adjustment feature to affect decompression calculations or reduce
the PO
2
setting to affect oxygen exposure.
WARNING
Set the correct Altitude Adjustment Mode when diving at altitudes greater than
300 m [1000 ft] the Altitude Adjustment feature must be correctly selected
in order for the computer to calculate the decompression status. The dive
computer is not intended for use at altitudes greater than 3000 m [10000 ft].
Failure to select the correct Altitude Adjustment setting or diving above the
maximum altitude limit will result in erroneous dive and planning data.
Содержание Mosquito
Страница 1: ...SUUNTO MOSQUITO EN USER S GUIDE ...
Страница 96: ...94 TABLE 7 2 NO DECOMPRESSION TIME LIMITS MIN FOR VARIOUS DEPTHS FT FOR THE FIRST DIVE OF A SERIES ...
Страница 116: ...114 ...
Страница 117: ...115 ...
Страница 120: ...Serial number Model of computer ...
Страница 121: ...Suunto s dive computers and wristop computers can be registered online at www suunto com ...
Страница 122: ...www suunto com Made in Finland Suunto Oy 06 2004 04 2006 ...