6 Technical data
6 Technical data
6.1 General data
FCC ID: 2ASK2-SUTO-003
Parameters
Flow: Actual volumetric flow: l/min, m
3
/h,
m
3
/min, cfm
Consumption: m
3
, ft
3
Medium pressure: bar, psi
Principle of measurement Thermal mass flow
Sensor
Glass coated resistive sensor
Measuring medium
Air
Ambient temperature
/Transport temperature
0 ... +50°C / -30 ... +70°C
Medium conditions
0 ... +50°C, rH<90% no condensation
Pressure range
0.01 ... 1.60 bar(a)
Material
Process connection: aluminum alloy
Wetted parts: aluminum alloy
Top casing: PC + ABS
Protection class
IP54
Dimensions
See dimensional drawing on page
Display
4-digit LED display
Tube diameter
DN8, DN15, DN20, DN25
Process connection:
G inner thread ISO 228-1
Weight
0.43 kg (DN8), 0.46 kg (DN15)
0.96 kg (DN20), 0.97 kg (DN25)
6.2 Electrical data
Power supply
15 ... 30 VDC, 120 mA @ 24 VDC