Date: November 2016
Issue No: 2
Crewsaver -
Servicing Manual : Offshore 290 Lifejacket
Page
of 35
32
Fig 8.3 Repacking the Offshore 290N (cont.)
8
Section
Fold in the corners of the top of the inflation chamber.
Ensure light water activator is layed on top of the folded
chamber with the cord placed to avoid any snags.
Tuck inside cover
8
Zip cover up to the oral tube and close velcro burst tabs.
9
Turn jacket around to pack the Right side.
Fold lower edge of the right side up over the tie in point.
Ensure capsule and lanyard lay on top of the folded up
inflation chamber.
Fold outer corner in and tuck inside cover.
Fold the Right inner edge of Inflation chamber to the right
as far as it will go..
11
10