background image

  

 

 

Surveon Network Camera Hardware Manual 

LED Indicators: 

Green 

Shows steady green for normal operation, flashing 
when the camera is accessed. 
Note: The Status LED can be configured to be 

unlit. 
Steady during startup, reset to factory default or 
when restoring settings. 

Amber 

Flashes every 0.2 sec during firmware upgrade. 
(On:0.2 sec, Off: 0.2 sec) 

Note: Startup or reboot may have failed if the status LED shows 
steady amber for over 1 minute. 

Status 
LED 
(rear) 

Unlit No 

network 

connection. 

 

Содержание CAM3365

Страница 1: ...CAM3365 3 Megapixel IR Bullet Outdoor Network Camera Hardware Manual Release 1 0 February 2011 ...

Страница 2: ......

Страница 3: ...tations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose Furthermore Surveon Technology reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation to notify any person of such revisions or changes Product specifications are als...

Страница 4: ...t Overview 1 1 1 Features and Benefits 1 Chapter 2 Hardware Overview 2 2 1 Front View 2 2 2 Rear View 3 2 3 Dimensions 3 2 4 Cables 4 2 5 Bracket Sealing 4 2 6 Functions 5 Chapter 3 Troubleshooting 8 3 1 Checking Firmware Version 8 3 2 Upgrading Firmware 8 3 3 Emergency Recovery Procedure 8 3 4 Resetting to Factory Default Settings 9 Chapter 4 Technical Specifications 10 ...

Страница 5: ...stalled according to specifications Provide a suitable power source with electrical overload protection Do not overload the AC supply branch circuit that provides power to the device ESD Precautions Please observe all conventional anti ESD methods while handling the device The use of a grounded wrist strap and an anti static work pad are recommended Avoid dust and debris in your work area Device S...

Страница 6: ...to radio or television reception which can be determined by turning the equipment off and on you are encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consu...

Страница 7: ...pplicable laws and regulations Surveon is applying its own internal efforts and expertise and is working closely with customers and suppliers to achieve compliance while maintaining an uninterrupted supply of quality products Surveon is currently investigating evaluating and qualifying our materials and components to ensure that products sold on or after 1 July 2006 in such territory are in compli...

Страница 8: ......

Страница 9: ...es Dual Streaming Dual stream design enables simultaneous support of real time video monitoring video recording or mobile viewing applications which require different resolutions compression formats and frame rates microSD SDHC card slot IP surveillance relies on network connectivity making it susceptible to attacks on the network between the camera and recording facilities With onboard recording ...

Страница 10: ...www surveon com 2 Surveon CAM3365 Chapter 2 Hardware Overview 2 1 Front View ...

Страница 11: ...3 Surveon Network Camera Hardware Manual 2 2 Rear View 2 3 Dimensions ...

Страница 12: ...AM3365 2 4 Cables 2 5 Bracket Sealing We suggest that the bracket be sealed after positioning the camera to ensure the weatherproof characteristics of the camera are maintained The figures show the positions that should be sealed ...

Страница 13: ...crophone Audio out can be connected to a public address system or an active speaker with a built in amplifier A pair of headphones can also be attached Power connector The power connector and supplied power adapter is provided for solutions without PoE I O terminal connector The I O terminal connector provides an RS 485 interface one transistor output two digital inputs and connection points for a...

Страница 14: ...t not be exposed to voltages greater than 30V DC DI2 Digital Input Pin 4 Connect to GND to activate or leave floating or unconnected to deactivate Must not be exposed to voltages greater than 30V DC DO Digital Output Pin 5 Uses an open collector NPN transistor with the emitter connected to the GND pin If used with an external relay a diode must be connected in parallel with the load for protection...

Страница 15: ...d Note The Status LED can be configured to be unlit Steady during startup reset to factory default or when restoring settings Amber Flashes every 0 2 sec during firmware upgrade On 0 2 sec Off 0 2 sec Note Startup or reboot may have failed if the status LED shows steady amber for over 1 minute Status LED rear Unlit No network connection ...

Страница 16: ...o System Firmware Upgrade 3 Choose Specify the firmware to upgrade Click Browse and locate the file 3365fw 4 The LED will flash amber during the firmware upgrading The camera will start reboot after firmware upgrade completed 5 When the LED indicator turns green the firmware is upgraded successfully 3 3 Emergency Recovery Procedure If the status LED shows steady amber for over 1 minute the camera ...

Страница 17: ...ator changes to back to Green which may take up to 1 minute the process is complete The default IP address is 192 168 88 10 if not assigned by a DHCP server Note Resetting to the factory default settings using the Reset button will cause all parameters including the IP address to be reset To reset the unit without changing parameters disconnect and reconnect the power adapter To check for updated ...

Страница 18: ...x 1536 Video control Auto Gain Control Auto White Balance Auto Electronic Shutter Backlight Compensation Image Adjustment Frame rate 15 fps at QXGA 2048 x 1536 30 fps at 1080P 1920 x 1080 30 fps at SXGA 1280 x 1024 30 fps at HD720 1280 x 720 30 fps at VGA 640 x 480 30 fps at QVGA 320 x 240 Video stream 2 simultaneous streams at H 264 MPEG 4 and MJPEG Bit rate 32K 10Mbps VBR CBR Intelligent video M...

Страница 19: ...e microSD SDHC card slot x 1 Class 4 Class 6 only RS 485 1 2 pins on terminal block SDK Surveon SDK 2 0 OS Microsoft Windows XP Vista 7 32 bit Browser Microsoft IE 6 0 or above Software Surveon VMS 2 4 1 Temperature Operation 20 C 50 C 4 F 122 F Non operation 30 C 60 C 22 F 140 F Humidity 5 95 non condensing Power 12VDC PoE IEEE 802 3af with Class 3 Power consumption Max 9 6 W w o Heater no AUX Po...