surveillance 112 PZ0312 Скачать руководство пользователя страница 11

 

11

this item, you can set continuous preset positions in this route, every route can set 16 preset positions 
(Note: this function shortcut key and number can't use as preset positions ). You can set the speed 
between every positions (50~128 level). You can set the stay time of every position (1~240 seconds).   

Run tour

--------press the key "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to working this cruise scan, now 

the camera starting cruise scan action, and exit all menu. 

Used state

--------select this item, then press the key "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to confirm 

select this item, shake the joystick up / down to select use this route or don't use. After finish the set, 
press the key "Iris" (or the key "CLOSE" / "RETURN" on the keyboard ) to back to previous menu. 

 
Auto scan setting: 

Shake the joystick up / down to make the cursor be under the "AUTO SCAN" item, then press the key "Iris+" (or the key 
"OPEN" / "ENTER" on the keyboard ) to confirm select this item, and enter the next sub menu: as the sheet: 

SCAN SPEED      060 

SCAN POSITION 

 
Scan speed

: select this item, then press the key "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to confirm, 

shake the joystick up / down to change the scan speed (10~80 level), default is 60

th

 level.   

Scan position

: select this item, then press the key "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to confirm, 

use the keyboard, you can adjust camera pitch angle and zoom, let the camera to remember it. 

 

Limit scan: 

Shake the joystick up / down to make the cursor be under the "LIMIT SCAN" item, then press the key "Iris+" (or the key 
"OPEN" / "ENTER" on the keyboard ) to confirm select this item, and enter the next sub menu: as the sheet 

SCAN SPEED                060 

SCAN POSITION 

LEFT LIMIT 

RIGHT LIMIT 

Scan speed

: select this item, then press the key "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to confirm, 

shake the joystick up / down to change the scan speed (10-80 level), default is 60

th

 level.   

Scan position

: elect this item, then press the key "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to confirm, 

use the keyboard, you can adjust camera pitch angle and zoom, let the camera to remember it. 

Left limit

: select this item, then press the key "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to confirm, shake   

          the joystick up / down to set the position (starting point).   

Right limit

: select this item, then press the key "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to confirm, 

shake the joystick up / down to set the position (ending point). 

 

4.5.2    Auto flip function 

Shake the joystick up / down to make the cursor be under the "AUTO FLIP" item, then press the key "Iris+" (or the key 
"OPEN" / "ENTER" on the keyboard ) to confirm select this item, select ON/OFF, the factory default is ON. 
 

4.5.3    Home (Fixed) position 

Shake the joystick up / down to make the cursor be under the "HOME " item, then press the key "Iris+" (or the key 
"OPEN" / "ENTER" on the keyboard ) to confirm select this item, then you can use the keyboard to adjust the camera to 
be the best condition, to set a fixed position as its home position. 

 

4.6  Calendar setup 

Shake the joystick to operate, press "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to confirm select this item, 

and enter the sub menu.   

TIME SET   

TIME DISPLAY           DISPLAY / OFF 

TIMING ACTION NO.                001 

TIMING ACTION TIME       010 

TIMING ACTION                    NOTHING                          

 
TIME SET: select this item, then press "Iris+" (or the key "OPEN" / "ENTER" on the keyboard ) to confirm, move joystick 

Содержание PZ0312

Страница 1: ...1...

Страница 2: ...of preset positions Pelco D P protocol 12 Indoor Outdoor Normal High Speed Dome Camera W O IR 13 1 Features 2 Mounting size drawing 2 1 Wall mount 2 2 hoisting mount 3 hardware setting 14 3 1 Dial co...

Страница 3: ...in order to package and transport it in the future Warning A Don t put it near to inflammable and explosive things please keep it far away dangerous areas B Don t put it on the unstable or supporter...

Страница 4: ...he supporter from box draw a central position of the drilling hole on the wall b Use M8 electrical hammer to dill 4 holes on the position that out of the central position then fix M6 screws in it c In...

Страница 5: ...255 z Baud rate 2400 4800 9600 19200 set by dial codes z Horizontal rotating range 0 360 continuously z Horizontal rotating speed 0 220 sec z Vertical rotating speed 0 100 sec auto flip z Working tem...

Страница 6: ...ary Add Binary Add Binary Add 0000000 0 11110000 15 01111000 30 10110100 45 10000000 1 00001000 16 11111000 31 01110100 46 01000000 2 10001000 17 00000100 32 11110100 47 11000000 3 01001000 18 1000010...

Страница 7: ...sition to enter main menu then see a sheet as below Use the joystick up down to select item then press the key Iris or the key OPEN ENTER on the keyboard to confirm select this item or enter the next...

Страница 8: ...s menu and back to the previous menu Leisure act means the camera haven t any actions after a period of time which you set if you don t control it beyond this time it will auto working a action you se...

Страница 9: ...selectable ON OFF selectable by useing the key zoom RESET restore factory settings EXIT return ID ID of every camera in order to control all cameras more conveniently from 1 255 FOCUS FOCUS MODE AUTO...

Страница 10: ...ick up down to change the scanning routes 001 002 2 routes are settable Set pattern select this item then press the key Iris or the key OPEN ENTER on the keyboard to confirm select this item start to...

Страница 11: ...rd to confirm select this item and enter the next sub menu as the sheet SCAN SPEED 060 SCAN POSITION LEFT LIMIT RIGHT LIMIT Scan speed select this item then press the key Iris or the key OPEN ENTER on...

Страница 12: ...Call 34 preset position Back to initial position Call 38 preset position 360 auto scan Set 40 preset position Delete all preset positions Preset position number of tour scan route and call delete com...

Страница 13: ...3 1 Dial codes switch setting Open the codes cover on top of dome cover see the dial codes of 10 numbers you can turn every number ON or OFF 3 2 Baud rate setting High speed dome camera can auto iden...

Страница 14: ...ntify baud rate address codes to be right Different factories have different address codes so sometimes you need to add 1 or cut 1 when you setting address codes For example you set the address code o...

Страница 15: ...ake the joystick up down to select then press the key Iris or the key OPEN ENTER on the keyboard to confirm select this item CAMERA TITLE ON OFF COORDINATE ON OFF TEMPERATURE ON OFF ZOOM OFF Press the...

Страница 16: ...rsor be under the SYSTEM RESET item then press the key Iris or the key OPEN ENTER on the keyboard to confirm select this item then screen appears you need to enter the camera secret codes then press t...

Страница 17: ...5 B 1 255 EXIT AGC AGC AUTO MANU LEVEL 1 16 BEIGHTNESS AUTO 1 15 SHUTTER AUTO 1 50 10K EXIT MODE BLC ON OFF D N AUTO DAY NIGHT MIRROR ON OFF PROTOCOL VISTA PELCO D Don t change this protocol otherwise...

Страница 18: ...key and number can t use as preset positions You can set the speed between every positions 50 128 level You can set the stay time of every position 1 240 seconds Run tour press the key Iris or the key...

Страница 19: ...joystick up down to change display mode default set is OFF TIMING ACTION NO select this item then press Iris or the key OPEN ENTER on the keyboard to confirm move joystick up down to change action nu...

Страница 20: ...achine regularly Lightning protection This products use TVS lightning protecting technology it can protect the equipment in these situations momentary lightning striking power voltage below 1 5W elect...

Страница 21: ...21...

Страница 22: ...is crooked Move and adjust its position Power is not enough Change the power Image is unstable Video wires are poor connection Rule out Power is not enough Change the power Video route is bearing int...

Страница 23: ...MID HIGH WDR BLC OFF WDR BLC STRONG LIGHT RESTRAINT BRIGHTNESS 0 100 SHUTTER X512 X2 AUTO OFF ANTI FLICKER 1 160 1 90000 SENS UP OFF AUTP X2 AUTO X128 INITIAL SET EXIT BACK TO PREVIOUS MENU BACK TO MA...

Страница 24: ...CUS MODE FOCUS DIST ZOOM START ZOOM END ZOOM SPEED INITIAL EXIT AWB AUTO WHITE BALANCE AWB MODE RED CONT BLUE CONT PUSH AUTO INITIAL EXIT AE AUTO EXPOSURE AE MODE BRIGHTNESS FLICKERNESS SHUTTER SPD IR...

Страница 25: ...en the camera focused object have strong light to shine it from its back the image will be dark you ca use this function to adjust the image The sensitivity of BLC can be HIGH MID LOW OFF MOTION DETEC...

Страница 26: ...NAL SYCN COMMUNICATION BAUD RATE 2400 9600 19200 ASYNCHRONOUS MODE set parity as NO PARITY ODD PARITY EVEN PARITY EXIT IMAGE ADJUST HORIZONTAL INVERSE VERTICAL INVERSE SHARPNESS this can make object e...

Отзывы: