DEFINITIONS

CAUTION: Risk of minor/moderate injury if precaution 
not taken.

WARNING: Risk of death/serious injury if warning  
isn’t heeded.

DANGER: Risk of death/serious injury if danger  
isn’t avoided.

SAFETY SYMBOLS USED

   

CAUTION: Important information, read the 
provided instructions carefully

 

 WARNING: Potential electric shock hazard

  

WARNING: High voltage

  Protective earth connection

  

Action prohibited

 

 

 

DEHUMIDIFIER SAFETY GUIDE

Please read the information in this document carefully 
prior to attempting the installation, operation and/
or servicing of the dehumidifier unit. This document 
contains all information required to install and operate 
the Surna dehumidifier device. Failure to follow the 
directions provided could cause damage to the 
dehumidifier equipment and/or accessory equipment, 
damage to building facilities, and/or serious injury or 
death to the operator. Please adhere to all applicable 
safety guideline requirements in this document and all 
applicable electrical and mechanical jurisdictional codes. 
Using Surna dehumidifying equipment in a manner not 
described in this manual may void unit warranty.

 

 

    

Prior to providing power to the equipment, be sure 
to inspect the area for water spills, which may present 
a shock hazard to the user. Take extra care to mount 
accessory electrical equipment away from areas regularly 
exposed to water. Be sure to provide secure wire and 
cable routing to protect personnel from shock hazards.

 

 

    

Consult with a licensed electrician before attempting 
electrical installation. DO NOT operate the unit outside 
specified operating parameters as given in the 

intended 

application 

section. Only operate the equipment with 

an appropriately sized switch or circuit breaker in place. 
Only operate equipment with adequate wire sizes and 
current carrying capacity. The switch or circuit breaker 
shall be accessible without the use of a tool, shall be 
easily accessible to users, shall be clearly marked with 

WARNINGS

6

Содержание 250 PPD

Страница 1: ...SURNA 250 PPD DEHUMIDIFIER OPERATING AND MAINTENANCE MANUAL surna com Model 3 250 March 2019...

Страница 2: ......

Страница 3: ...TABLE OF CONTENTS Specifications 4 Technical Description 5 Warnings 6 Warranty Information 8 Installation Instructions 10 Operation Instructions 18 Routine Maintenance 19 Troubleshooting 21 3...

Страница 4: ...Condensate Drain 3 4 NPT ELECTRICAL Volts Phase 208 230V Single Nominal Current Draw 12 8A 12 0A Maximum Overcurrent Protection 20A Power Factor 99 PERFORMANCE 40 45 50 55 60 65 70 50 100 150 200 250...

Страница 5: ...hich act like an expansion valve Refrigerant then flows to the evaporator coil The evaporator coil is where heat is transferred from the incoming air to the liquid refrigerant causing it to evaporate...

Страница 6: ...adhere to all applicable safety guideline requirements in this document and all applicable electrical and mechanical jurisdictional codes Using Surna dehumidifying equipment in a manner not described...

Страница 7: ...fied licensed service technician DO NOT use extension cords or plug adapters These actions may result in a fire hazard or electric shock This unit must be connected to a protective earthing system pri...

Страница 8: ...bilities under this Warranty are limited to furnishing replacement equipment or parts at its option FCA Incoterms 2000 factory or warehouse f o b factory or warehouse for US domestic purposes at Compa...

Страница 9: ...vidual order 1 Surna 250 PPD dehumidifier 2 Surna 250 PPD dehumidifier product manual 3 Humidistat 4 15 ft of thermostat wire 5 PVC condensate trap INTENDED APPLICATION The Surna dehumidifier is inten...

Страница 10: ...ust in line with cold air exhaust from other air handling or cooling units circulatory fans Improper positioning will decrease unit efficiency and could cause damage to the unit ELECTRICAL This unit i...

Страница 11: ...n overflow Use of a p trap reference figure 2 is required to avoid pressure and vacuum related issues which can negatively affect condensate drainage Following plumbing installation the system should...

Страница 12: ...Pan Vent Mounting Brackets P Trap Drain Airflow In Airflow Out Ceiling 12 min clearance Exhaust min 24 Clearance Air Intake min 24 Clearance Figure 2 Installation diagram shows proper mounting of Sur...

Страница 13: ...tructure in front of intake or discharge A FLOW FLOW 3 W O L F W O L F REQUIRED UNIT CLEARANCES Figure 3 Required minimum clearances for Surna dehumidifier A Minimum 12 inches 30 5 cm of clearance abo...

Страница 14: ...a e l c f o s e h c n i 2 1 n i M A B Min 24 inches recommended 72 inches between 2 units with adjacent intakes FLOW FLOW FLOW FLOW B 4 FLOW FLOW 3 1 or 2 5 A A Minimum 12 inches 30 5 cm of clearance...

Страница 15: ...ing fans within 3 feet recommended 72 inches from intake or discharge of unit A Min 12 inches of clearance above and below FLOW FLOW FLOW FLOW FLOW FLOW A A 3 A Minimum 12 inches of clearance above an...

Страница 16: ...humidifier Oppose flow by 90 degrees for neighboring units No conditioned air discharge or circulating fans within 3 feet minimum recommended 72 inches from intake or discharge of unit A Minimum 24 in...

Страница 17: ...DELAY RELAY HUMIDITY CONTROL FAN MOTOR COMPRESSOR CAP FAN RELAY COMPRESSOR RANCO TEMP CONTROL RED YELLOW BLUE BLK WHITE RED BLUE BLK RED BLUE LINE NEUTRAL WHITE COM ORANGE 240 VAC RED 24 VAC BLUE BLUE...

Страница 18: ...ont of the unit to the ON position and set the provided humidity controller to the desired setting for the space A D DRAWN Mounting Brackets Filter Set Screw Dehumidistat Switch Connector ON OFF Toggl...

Страница 19: ...e of the unit DO NOT use coil cleaner that is designed for outdoor coils as it may be corrosive The Surna Dehumidifier comes equipped with an electrostatic filter If properly maintained electrostatic...

Страница 20: ...f it is not possible to clean the filter to the point where light is able to shine through the filter should be replaced 6 Let filter air dry for at least 10 minutes The filter can be used damp but no...

Страница 21: ...istat is set to on NOTE The Surna dehumidifier is intended to operate in temperatures above 70 F 21 C and relative humidity of 45 or higher Temperature and relative humidity affect performance Contact...

Страница 22: ...NOTES 22...

Страница 23: ...NOTES 23...

Страница 24: ...surna com 1780 55th Street Boulder CO 80301 303 993 5271 info surna com A P E 24...

Отзывы: