background image

5

SC-TDC-1100 Series Manual

2   General Information

2.1   General Information

This manual is intended to assist users in the operation of the Releases 212, 312 and 322 of the SC-TDC-1100 

series. It is divided into 4 chapters. The chapter “General Information” contains a brief overview of the 

devices as well as the safety instructions. The chapter “Installation” refers to installation and cabling. The 

other chapters contain amongst others technical details and the description of the device layout.

2.2   Safety Instructions

The “caution symbol” marks warnings, which are given to prevent an accidental damaging 

of the detector or the readout system. Do NOT ignore these warnings and follow them 

strictly. Otherwise no guarantee is given for arose damages.

Note

The “note symbol” marks text passages, which contain important information/hints 

about  the  operation  of  the  detector.  Follow  these  information  to  ensure  a  proper                            

functioning of the detector.

The “high voltage symbol” marks warnings, given in conjunction with the description of 

the operation/use of high voltage supplies and/or high voltage conducting parts.

Hazardous voltages are present, which can cause serious or fatal injuries. Therefore 

only persons with the appropriate training are allowed to carry out the installation, 

adjustment and repair work.

Please read this manual carefully before performing any electrical or electronic operations and strictly 

follow the safety rules given within this manual. Surface Concept declines all responsibility for damages 

or injuries caused by an improper use of the module due to negligence on behalf of the User.

The following symbols may appear throughout the manual:

Please also respect the Surface Concept Device Safety Instructions Manual in addition 

and all given safety rules within it.

Note

SC-TDC-1100 Series Manual | Surface Concept GmbH

Содержание SC-TDC-1100 Series

Страница 1: ...Time to Digital Converter SC TDC 1100 Series Release 212 312 322 Manual...

Страница 2: ...e 49 6131 62716 0 fax 49 6131 62716 29 email info surface concept de web www surface concept de All rights reserved No part of this manual may be reproduced without the prior permission of Surface Con...

Страница 3: ...3 Installation 7 3 1 Initial Inspection 7 3 2 Cabling 7 3 3 Software Installation Requirements and Interface 9 4 TDC Layout 11 4 1 Schematic Description 11 4 2 Layout of the SC TDC 1100 Series 12 4 2...

Страница 4: ...4 T h i s s i d e h a s b e e n l e f t b l a n k o n p u r p o s e SC TDC 1100 Series Manual Surface Concept GmbH...

Страница 5: ...mation hints about the operation of the detector Follow these information to ensure a proper functioning of the detector The high voltage symbol marks warnings given in conjunction with the descriptio...

Страница 6: ...in Release 312 and 322 is laid out for NIM signals on LEMO 00 type connectors in Release 212 it is laid out for low voltage LV TTL signals on BNC connectors for all stop and the start inputs All othe...

Страница 7: ...r provider immediately Please check the delivery according to the packing list see Table 1 for completeness SC TDC 1100 R212 R312 R322 1x USB cable 1x power cable Table 1 Packing list for the SC TDC 1...

Страница 8: ...ls see Chapter 4 2 2 for detailed information Use the USB cable to connect the TDC to the PC Do not use PC front panel USB connectors they are often restricted in performance see Chapter 3 3 for furth...

Страница 9: ...tall the software package as described in the Software Installation Manual Read out of the TDC is done with a standard PC via USB3 0 For the PC the following minimum system requirements are highly rec...

Страница 10: ...10 T h i s s i d e h a s b e e n l e f t b l a n k o n p u r p o s e SC TDC 1100 Series Manual Surface Concept GmbH...

Страница 11: ...only informative Figure 2 Schematic sketch of TDC functioning Arrival times of pulses at the stop inputs are measured by the TDC with respect to either an internal reference start signal provided by t...

Страница 12: ...Sockets for Device Synchronization Signal IN and OUT 4 USB Connection Socket 5 Power switch to turn the TDC ON OFF Lighted when set to ON 6 Power Socket Figure 3 Front Panel of SC TDC 1100 08S R212 a...

Страница 13: ...x_Start X X is either NO or YES The default setting is YES Ext_Gpx_Start YES must be set for the TDC to accept the external start signal In addition the following entries in the tdc_gpx3 ini must be s...

Страница 14: ...easy to be identified as such For applications with time distances larger 10 7 s R212 and 40 s R312 R322 use the start counter or the extended measurement range see Chapter 4 2 5 Note The temporal res...

Страница 15: ...Hz To cope with larger start frequencies the SC TDC 1100 devices are equipped with an internal start frequency divider for external start frequencies of up to 150MHz this mode only works when using th...

Страница 16: ...inputs of the TDC must be used to apply the external start signal which reduces the number of available stop inputs by one Additionalchangesinthetdc_gpx3 inifilemustbemadefortheextendedmeasurementran...

Страница 17: ...asured in reference to themselves With such definition the results from channel 3 provide the time between two subsequent signals on channel 3 in case that this signal is a periodic signal the time re...

Страница 18: ...18 T h i s s i d e h a s b e e n l e f t b l a n k o n p u r p o s e SC TDC 1100 Series Manual Surface Concept GmbH...

Страница 19: ...fold multi hit capability per channel 40MHz internal device measurement rate Stop Signal Input Low voltage TTL on 50Ohm BNC socket External Start Signal Input Low voltage TTL on 50Ohm BNC socket Exte...

Страница 20: ...ble resolution insensitive to temperature variations adjustable via software no calibration necessary Digital time bin resolution per channel 82 3ps 5 5ns pulse pair resolution on one channel and 0ns...

Страница 21: ...t NIM on LEMO 00 socket External Start Signal Input NIM on LEMO 00 socket Device Synchronization Signal Input Low voltage TTL on 50Ohm BNC socket Device Synchronization Signal Output Low voltage TTL o...

Страница 22: ...in resolution per channel 27 4ps 5 5ns pulse pair resolution on one channel and 0ns between two channels Trigger to rising edge Start retrigger rate max 9MHz Measurement range 0ns 40 s in start stop o...

Страница 23: ...100 Series Manual Surface Concept GmbH Figure 1 General connection scheme of the SC TDC 1100 devices 7 Figure 2 Schematic sketch of TDC functioning 11 Figure 3 Front Panel of SC TDC 1100 08S R212 and...

Страница 24: ...the following standards or other normative documents where relevant EN 61000 6 2 2005 AC 2005 Electromagnetic compatibility EMC Generic standards Immunity for industrial environments EN 61000 6 4 200...

Отзывы: