396
-
3815Y1 SureFire PumpRight for Raven RCM
48
Revised 12/04/2019
Initial Operation in AUTO mode: (Could also do Nozzle Flow Check).
1.
Enter a
Test Speed
by pressing on the
Speed (mph)
window or at
Setup > Applicator Setup
.
2.
Toggle system to
AUTO / ENABLED.
Select a Rate.
3.
Height switch must be DOWN (or uncheck Height Switch box).
4.
Turn on
Master Switch
.
5.
Monitor Actual Rate (gal/ac), Flow (gal/min), PSI, DC, Pump RPM.
6.
Go to
Switch Box
(above). Turn Sections OFF and ON.
7.
Turn Master Switch OFF. (NOTE: Pressure will be much less with water than with heavier, thicker fertilizer.)
Initial Operation in MANUAL mode: (See Optional Manual Pump Operation below)
1.
Fill the system with water. For first time startup, open air bleed valve until a steady stream comes out.
2.
Enter a
Test Speed
by pressing on the
Speed (mph)
window or at
Setup > Applicator Setup
.
3.
Navigate to
MANUAL MODE
as shown above (toggle between Auto and Manual with the Auto/Manual button).
4.
ENABLE
system (toggle between Enable / Disable with the Enable / Disable button).
5.
Height switch must be DOWN (or uncheck Height Switch box).
6.
Turn on
Master Switch
. Press and hold + to increase flow.
7.
Monitor Flow (gal/min), PSI, DC, Pump RPM (if using Hydraulic pump with RPM sensor).
8.
Go to
Switch Box
. Turn Sections OFF and ON.
9.
Turn Master Switch OFF.
OPTIONAL MANUAL PUMP OPERATION:
Go to
Diagnostics > Tests > Calibrate PWM LIMITS.
Here you can manually run the pump without the system shutting
down if it doesn
’
t read flow immediately. Turn on Master Switch, Start the test, hold + button to increase pump speed.
Advanced Setup and Operating Information, Run Page, Initial Startup
AUTO MODE / DISABLED
MANUAL MODE / DISABLED
AUTO MODE / ENABLED
MANUAL MODE / ENABLED
If flow or pressure is not immediately detected, the
Solution Pump Dry
warning will come up and the system will shut down.
Solution Pump Dry
is NOT a problem for SureFire electric pumps or for
SureFire PumpRight hydraulic diaphragm pumps. It is a problem for
centrifugal pumps.
Solution Pump Dry
will not come up in
Diagnostics > Tests> Calibrate
PWM Limits.
Read the
for safety information and additional setup/operating information.
F
SureFire
Ag
Systems
Содержание PumpRight D250
Страница 2: ...S u r e F i r e A g S y s t e m s...
Страница 6: ...396 3815Y1 SureFire PumpRight for Raven RCM iv Revised 12 04 2019 S u r e F i r e A g S y s t e m s...
Страница 23: ...396 3815Y1 SureFire PumpRight for Raven RCM 17 Revised 12 04 2019 S u r e F i r e A g S y s t e m s...
Страница 31: ...396 3815Y1 SureFire PumpRight for Raven RCM 25 Revised 12 04 2019 D Wiring S u r e F i r e A g S y s t e m s...