Страница 1: ...tions are subject to change without notice 2004 by SURECOM Technology Corporation All rights reserved Page1 2D EP 824DX FS 24 Port 10 100M Ethernet Rack Mount Switch With Fiber Support User Guide 4718...
Страница 2: ...perated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measur...
Страница 3: ...COM port configuration 14 3 1 Status 18 3 1 1 Status Overview 19 3 1 2 Status MIB Counter 20 3 2 Configuration 22 3 2 1 Configuration Port 23 3 2 2 Configuration Trunking 24 3 2 3 Configuration Global...
Страница 4: ...10Mbps and auto detecting mode full duplex or half duplex thereby providing you with automatic and flexible solutions in your network connections 6 Auto polarity detection for correction of incorrect...
Страница 5: ...t on the Switch to any device such as a workstation or a server Store and Forward Scheme The Switch uses store and forward switching to ensure all error packets will be filteredand maintain maximum da...
Страница 6: ...TX 100BASE FX UTP Cat 3 4 5 Max cable length 100m UTP Cat 5 Max cable length 100m Multi mode Fiber cable Max cable length 2000m Single mode Fiber cable Max cable length 30 or 60 km No of Ports 24 100...
Страница 7: ...ork communication system developed and standardized by DEC Intel and Xerox using baseband transmission CSMA CD access logical bus topology and coaxial cable The successor IEEE 802 3 standard provides...
Страница 8: ...create a single high speed logical link that combines several lower speed physical links Virtual LAN VLAN A Virtual LAN is a collection of network nodes that share the same collision domain regardles...
Страница 9: ...alls within the rate limit is transmitted while packets that exceed the acceptable amount of traffic are dropped IGMP Snooping Listening to IGMP Query and IGMP Report packets transferred between IP Mu...
Страница 10: ...ront panel LED indicators and rear panel on the Switch 2 1 Overview 24 10 100Mbps RJ 45 Ports Uses these twenty four ports to connect to networked PCs or another Switches Hubs Each port uses auto nego...
Страница 11: ...onal network link through the corresponding port with an attached device Flashing Blinks to indicate that the router is actively sending or receiving data over that port FDX COL Green On Lights to ind...
Страница 12: ...mode half or full duplex and data rate 10 or 100 Mbps can be selected automatically See the following section to get more details about connection of RJ 45 ports Connecting to PC or Server You can co...
Страница 13: ...the Switch to the Uplink port of a Hub or any port of another switch via straight cable with RJ 45 plugs at both ends When a attached 10BASE T 100BASE TX Hub is powered on or reset 10BASE T Hub The Li...
Страница 14: ...ftware Only after the terminal program setup is done you are thus able to proceed to set up the 24 Port 100 10M N Way Rack Mount Smart Switch Before you are able to access the 24 Port 100 10M N Way Ra...
Страница 15: ...indows O S Hyper Terminal The Connection Description Screen is displayed Type whatever you like in the Name panel to identify the connection choose an icon below Name panel and click OK 2 Since you wo...
Страница 16: ...4 by SURECOM Technology Corporation All rights reserved Page16 2D 3 This COM1 properties settings must be mandatory correct Follow the instructions as shown to complete the settings and click OK 4 Pow...
Страница 17: ...in screen click any key You can check configuration information program The following figure shows the main menu Select the item you want to configure by clicking the item number You can use the Funct...
Страница 18: ...SURECOM Technology Corporation All rights reserved Page18 2D 3 1 Status Select the Port Status sheet You can check each port s link status and configration information in this sheet Click F to get th...
Страница 19: ...by SURECOM Technology Corporation All rights reserved Page19 2D 3 1 1 Status Overview The Management Application shows one switch s information at one time Which displayed switches discovered in the n...
Страница 20: ...ic Counter Click the T There are three objects you can select such as Drop count CRC error count and Collision count Click the B Byte Count button Showing the each port s amounts of bytes are sent and...
Страница 21: ...ghts reserved Page21 2D 3 1 3 Status Port Status Select the Port Status sheet You can check each port s link status and configration information in this sheet Click the 1 Page up check Click the 2 Pag...
Страница 22: ...ice 2004 by SURECOM Technology Corporation All rights reserved Page22 2D 3 2 Configuration On the Configuration sheet you can configure Port Trunking Global QoS Priority Tag Inser Remove VLAN Global C...
Страница 23: ...on Click the F to get the latest information Enable Port force to enable or disable The LED will be still lighted even on disable status if the hardware connection still existed between NIC and switch...
Страница 24: ...g On the Enable Trunking sheet you can set up port trunks There are seven total to choose Please note that you can only choose one Trunk mode for use enable once from listed below while you do configu...
Страница 25: ...nformation Half Duplex Back Pressure Flow Under Half mode to prevent packet overflow a problematic state in which packets received and transmitted in excess of buffer memory capacity are dropped Recom...
Страница 26: ...nable this function the switch can recognize TCP IP Differentiated Services Codepoint DSCP priority information from the DS field defined in RFC2474 The DS field byte for IPv4 is the Type of Service T...
Страница 27: ...Control Ability The switch can automatically turn off 802 3x flow control and Back pressure flow control for 1 2 seconds whenever the port receives a high priority frames The flow control is re enable...
Страница 28: ...frame Set priority field 7 VID field 0 for high priority frame 3 Insert priority tag into the all untagged frame Set priority field 7 VID field 0 for high priority frame Set priority field 0 VID fiel...
Страница 29: ...and source port belong to a different VLAN ARP broadcast Packet Inter VLAN The packets with ARP frame will broadcast to all switch ports if enable this function IP Multicast Packet Inter VLAN This fun...
Страница 30: ...allows you to set the VLANs This switch supports Port based and 802 1Q VLAN This switch supports maximum of 32 VLAN group entries for setting in default but it may be less than 32 entries can be reall...
Страница 31: ...04 by SURECOM Technology Corporation All rights reserved Page31 2D 3 2 8 Configuration Device Features Setting IGMP Snooping Control register Click the 0 Return previous setting sheet Click the Space...
Страница 32: ...subject to change without notice 2004 by SURECOM Technology Corporation All rights reserved Page32 2D 3 3 Security This model does not support this function This function is only available on Windows...
Страница 33: ...ge shows some information about VLAN Network Loop Fault Test Trunk Link Warning When X appears that means the corresponding Trunk port does not link to switch after Trunk function be enabled Network L...
Страница 34: ...e without notice 2004 by SURECOM Technology Corporation All rights reserved Page34 2D 3 5 Load Factory Defaults Select 5 to load the factory default setting Please remember to select 6 for save it aft...
Страница 35: ...ct to change without notice 2004 by SURECOM Technology Corporation All rights reserved Page35 2D 3 6 Save Please do remembering saving your configuration after doing any changes Or the changes of conf...
Страница 36: ...arranty Period except as otherwise stated herein 2 Year Limited Warranty for the Product s is defined as follows Hardware excluding power supplies and fans Two 2 Year Power supplies fans and cables ar...