SureCall N-Range User Guide
www.SureCall.com | 1-888-365-6283 | [email protected]
8
Troubleshooting
Signal booster has no
power
Verify that the Power LED is ON.
Connect the power supply to an alternate power source.
Verify that the power source is operational and the fuse is intact.
If it remains OFF, contact tech support at:
1-888-365-6283 or [email protected]
After completing
installation, signal has
not Improved
Verify that cable connections are tightly fitted to the booster.
Note:
Bars are not always a reliable measure of signal. The best way to confirm signal
coverage is the ability to place and hold a call.
Specifications
Product
N-RANGE (SC-NRANGE)
Uplink Frequency Range (MHz):
698-716 / 776-787 / 824-849 / 1850-1915 / 1710-1755 (G Block Included)
Downlink Frequency Range (MHz):
728-746 / 746-757 / 869-894 / 1930-1995 / 2110-2155 (G Block Included)
Input / Output Impedance:
50 Ω
Maximum Gain:
23 dB
Gain Adjustment:
20 dB (Automatic)
Supported Standards:
CDMA, WCDMA, GSM, EDGE, HSPA+, EVDO, LTE and all cellular standards
Noise Figure:
≤ 7 dB
VWSR:
≤ 2.0
Maximum Output Power:
1 Watt EIRP
DC Power:
8-15VDC
Cable:
SC-174, 15 ft
RF Connectors:
SMA Female
Power Consumption:
< 12W
Operation Temperature:
14° F – 122º F
Dimensions:
5 x 3.5 x 3 in
Weight:
0.62 lbs (9.92 oz)
Certification:
FCC ID: RSNRANGE
IC: 7784A-RANGE
Note: The term “IC” before the radio certification number only signifies that Industry Canada technical specifica-
tions were met.