TABLE 2-5 DESCRIPTION OF KEYS (KEY1(ONOFF), KEY4(SET), KEY7(OK))

 

Status ONOFF

SET  OK 

Description 

 

Normal 
temperature 
display 

Turn 

on/off 

the 

display 

Upper 

limit 

setting 

Refer to 

instructions

If the current mode is mode 5 or 
6, press “OK” key will activate 
timer. Please refer to note 1 for 
more details of “OK” key.(note 1) 

Timer 
display 

Turn 

on/off 

the 

display 

Upper 

limit 

setting 

Timing 

pauses 

It’s not recommended to press 
the keys unless resetting the 
timer or modes is required. 

Upper limit 
setting 

Turn 

on/off 

the 

display 

Lower 

limit 

setting 

Lower limit 
setting 

Turn 

on/off 

the 

display 

/

 

setting 

/

 setting 

Turn 

on/off 

the 

display 

Timing 
setting 

Timing 
setting 

Turn 

on/off 

the 

display 

Working 

mode 

setting 

Working 
mode 
setting 

Turn 

on/off 

the 

display 

Upper 

limit 

setting 

Exit setting 

and save 

the setting 

to 

EEPROM. 

The setting 

won’t be lost 

when power 

drops. 

In these modes, after the 
operation of turning off the display 
and then turning on the display, 
the panel will normally display 
temperature. 

 

Note:  

1.  Instead of entering other working modes, the panel will normally display 

temperature after the operation of turning off the display and then turning on the 
display or the operation of repowering the panel after the power drops. Before 
pressing “OK” to activate the working mode, you’re suggested to use “Set” key to 
check the setting. 

2.  The panel will display temperature after the timing of MOD5/MOD6 ends. 
3.  All the settings (upper limit, lower limit, 

/

 display, timing and working mode) 

will be saved in EEPROM after power drops. 

4.  The upper and lower limits will correspondingly transact after the switching of 

/

. The limits and the temperature readings displayed have the same unit.   

5.  If you don’t press “OK” to exit the setting before the power drops or display is 

turned off, the current setting won’t be saved. 

6.  If the display is turned off during setting and then turned on, the panel meter will 

normally display temperature readings or timing.   

7.  The timing will pause when you press any key. Do not press any key during timing, 

or the timing won’t be accurate. 

8.  During normal temperature display, unplug or plug the DS18B20 will cause 

temporary wrong display (85

/185

) but without other affect. 

Содержание Remote Temperature Controller

Страница 1: ...Remote Temperature Controller User s Guide 2004 2010 Sure Electronics Inc ME PC11121_Ver1 0...

Страница 2: ...Overview 1 1 1 Overview 1 1 2 Features 1 1 3 Applications 2 1 4 Quick Start 2 Chapter 2 Setting 3 2 1 Pin Definition 3 2 2 Working Mode 3 2 3 Description of The Remote Control s Keys 4 2 4 Working Mod...

Страница 3: ...Remote Temperature Controller 2004 2010 Sure Electronics Inc ME PC11121_Ver1 0_Page ii NOTES Product Version Ver 1 0 Document Version Ver 1 0...

Страница 4: ...control It utilizes an external high precision water proof digital DS18B20 probe as the temperature sensor Used together with a 7 key remote control which is used to set the panel meter over the worki...

Страница 5: ...her DIY Applications 1 4 Quick Start 1 Connect the digital sensor DS18B20 as follows 2 Power the panel meter with a supply 12VDC as follows FIGURE 1 4 CONNECTION SCHEMATIC 3 Then the temperature from...

Страница 6: ...d Ti TH relay open Ti TH relay closed External heating devices are recommended MOD1 Take the upper limit TH as the threshold Ti TH relay closed Ti TH relay open External cooling devices are recommende...

Страница 7: ...IR encoding mode and integrates SC6122 IC as the remote control transmitter which utilizes CMOS Technology specially designed for use on infrared remote control applications FIGURE 2 2 OVERVIEW OF TH...

Страница 8: ...10 10 Lower limit setting 1 1 10 10 The upper limit should be or 5 higher than the lower limit The limits should be within the DS18B20 s measuring range of 55 to 125 67 to 257 setting Pressing any of...

Страница 9: ...the panel will normally display temperature Note 1 Instead of entering other working modes the panel will normally display temperature after the operation of turning off the display and then turning o...

Страница 10: ...T mode1 OK MOD2 External cooling devices Single threshold SET upper limit setting SET SET SET SET mode2 OK MOD3 External heating devices Hysteresis control SET upper limit setting SET lower limit sett...

Страница 11: ...Size Digit Display 3 digit 0 56 14 2 mm high LED F C Display 1 digit 0 39 9 9 mm high LED Relay Nominal Switching Capacity res load 10A 250VAC Switching Current 15 A Switching Voltage 250 VAC Switchi...

Страница 12: ...USER S GUIDE 2004 2010 Sure Electronics Inc Chapter 4 Mechanical Drawing FIGURE 4 1 MECHANICAL DRAWING OF FRONT PANEL FIGURE 4 2 MECHANICAL DRAWING OF BACK PANEL FIGURE 4 2 MECHANICAL DRAWING OF BASE...

Страница 13: ...e Electronics Inc Chapter 5 Appendix Due to the performance limitation of 7 segment display some letters and digits are constructed with special segment architecture The letters digits table is as fol...

Страница 14: ...ure Electronics Co Ltd East zone 3F Building 6 Jingang Technology Innovation Center No 108 Ganjiabian Rd ZIP 210000 Qixia District Nanjing P R China Tel 86 25 68154800 860 Fax 86 25 68154891 832 Websi...

Отзывы: