0.56
" Digital Red LED Automobile
Thermometer Panel Meter
User’s Guide
©
2004-2009 Sure Electronics Inc. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0
Страница 1: ...0 56 Digital Red LED Automobile Thermometer Panel Meter User s Guide 2004 2009 Sure Electronics Inc ME SP330 ME SP331 ME SP332 ME SP333_Ver1 0...
Страница 2: ...apter 2 Specification Characteristics 3 2 1 Specification Characteristics 3 Chapter 3 Features 4 3 1 Adapted to the Ambient Brightness 4 3 2 Slowly Adjust the Brightness of Diode 6 Chapter 4 How to Us...
Страница 3: ...0 56 Digital Red LED Automobile Thermometer Panel Meter 2004 2009 Sure Electronics Inc ME SP330 ME SP331 ME SP332 ME SP333_Ver1 0_Page ii NOTES Product Version Ver 1 0 Document Version Ver 1 0...
Страница 4: ...sensor ME SP331 External Probe ME SP332 External Probe Built in sensor ME SP333 External Probe External Probe Thermometers equipped with built in sensor such as ME SP330 and ME SP332 can be used to me...
Страница 5: ...ely display temp in C and F 4 Self adapted to ambient brightness not dazzling in night time since the brightness can be adjusted automatically 5 Large 0 56 14 2mm easy to read red LED display 6 Miniat...
Страница 6: ...be 31 24 257 125 F C Display Resolution 9 9 F C to 99 9 F C 0 1 F C Other range 1 F C Accuracy 0 C to 60 C External 0 1 0 1 5 C Internal 0 2 0 4 0 C Responding Rate 0 5 S Display Display Type and Size...
Страница 7: ...be too dazzling in night time 3 1 Adapted to the Ambient Brightness 1 The brightness of diode will reach its topmost when the panel meter is in a room under direct sunlight exposure 2 The brightness...
Страница 8: ...Thermometer Panel Meter 3 The brightness of the diode is the darkest when the panel meter in placed in an environment of almost no light from outside 2004 2009 Sure Electronics Inc ME SP330 ME SP331...
Страница 9: ...is shifted from light to dark or dark to light the brightness of diode will be gradually changed and whole process will last for 1 seconds The adjustment of brightness is smooth and it won t make peop...
Страница 10: ...rwise thermometer will be burnt out 3 When an external probe no matter a 2 pin or 3 pin version is to be connected with the pin header of thermometer always leave the pin 5V disconnected 4 2 Display M...
Страница 11: ...lly you will need to repeat the on off action twice You can also use flashlight even when the ambient luminance intensity exceeds 60 Lux when you switch off the flashlight cover your thermometer with...
Страница 12: ...temperature reading from CH1 will be displayed and CH2 means temperature reading from CH2 will be displayed 7 When Alternate display with the change of ambient brightness is selected you can have ther...
Страница 13: ......
Страница 14: ...DIGITAL RED LED AUTOMOBILE THERMOMETER PANEL METER USER S GUIDE 2004 2009 Sure Electronics Inc Chapter 5 Mechanical Drawing FIGURE 5 1 MECHANICAL DRAWING ME SP330 ME SP331 ME SP332 ME SP333_Ver1 0_Pag...
Страница 15: ...ronics Co Ltd 5F Zone A Qinhuai Technology Innovation Center 105 2 DaMing Rd ZIP 210022 Nanjing P R China Tel 86 13601408832 For technical questions only 86 25 66606340 English service from GMT1 10AM...