X-Station User Manual
- 22 -
Relay Connections
Connecting with a Fail Safe Lock
Connecting with a Fail Secure Lock
Note
•
N.O. (Normally Open): A control signal closes the circuit.
•
N.C. (Normally Closed): A control signal opens the circuit.
•
Take care of the direction of the diode.
•
Make sure to install the diode near to the door lock.
•
Make sure to use different power supplies for the X-Station and the door lock.
•
Make sure to install the diode at both ends of the circuit as shown in the figures above in order to protect the relay
contact from the reverse current that occurs when the door lock works.