1
General Information
1-2 Product Description
Main Device
Dip Switch Settings
ID Setting [Sets the RS-485 ID for the Lift I/O, Range: 0 ~ 31]
-
Binary Counting
(See Table Above)
SEC Setting [Enables Secure Mode Communication
(Must RESET Lift I/O)
]
-
ON: Secure Mode Enabled, OFF: Secure Mode Disabled
Aux Mode Settings [M0 – AC Fail, M1 – Low BAT, M2 - Tamper]
-
ON: Normal Open, OFF: Normal Closed
#
Item
Description
1
Reset &
Sync Buttons
RESET: Resets Lift I/O
SYNC: Synchronizes Lift I/O with host device
2
Output Ports
12ch: Form C Relay
3
Input Ports
12ch: Input (Currently Disabled)
4
Aux Input Port
3 Ports: AC Fail, Low Battery, Tamper
5
RS-485 &
Power Ports
RS-485: Communication with host device
Power: 12VDC, 1A
6
Dip Switches
ID: Lift I/O RS-485 ID
SEC: Secure Mode Toggle
M: Aux Input Port Modes [N.O. / N.C.]
1
6
3
4
5
2
Lift I/O ID
ID 0 State
ID 1 State
ID 2 State
ID 3 State
ID 4 State
0
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
5
ON
OFF
ON
OFF
OFF
…
31
ON
ON
ON
ON
ON
4