background image

Installation

 

12 

Connecting to an Automatic door 

How to configure a Relay 

Set up the relay according to the following steps only when BioStar is not used to set up the door. 

1

 

Press the 

MENU 

button, and then authenticate with the administrator authentication method. 

2

 

Select 

Device

 > 

Door

Relay

, and then press the 

OK

 button. 

3

 

Press the 

OK

 button after entering the time that the relay is on. 

4

 

Press the 

OK

 button after entering the time that you want. 

5

 

Select 

Door Sensor

, and then press the 

OK

 button. 

6

 

Press the 

OK

 button after selecting the port that will be used to control the door sensor. 

7

 

Select 

Exit Button

, and then press the 

OK

 button. 

8

 

Press the 

OK

 button after selecting the port that will be used to control the exit button. 

The 

INIT

 switch of Secure I/O 2 should be pressed after completing the relay setup when Secure I/O 2 is used together. 

Refer to BioStar administrator guide when setting up the door with BioStar. 

Note 

BioLite Net 

13  -  RLY  COM 

Green (White stripe) 

14  -  RLY  NO 

Gray (White stripe) 

Sensor 

Automatic door 

controller 

Door button 

Door lock 

14 
13 

Содержание BioLite Net

Страница 1: ...English Version 2 10 BioLite Net INSTALLATION GUIDE www supremainc com EN 101 00 BLN V2 10A...

Страница 2: ...roduct 9 Connecting to Power 10 Connecting to a Network 10 TCP IP 10 Connecting to an Door button Door sensor 10 Connecting to a Relay 11 Fail Safe Lock 11 Fail Secure Lock 11 Connecting to an Automat...

Страница 3: ...amaged due to a user s unauthorized installation or dismantling of the product a service fee will be charged for repair Operating Instructions Be careful not tospill any liquid suchas water drinks or...

Страница 4: ...o so may lead to an illegal intrusion Do not press the buttons onthe product with excessive force or witha sharp tool This can cause a failure Be careful not to contaminate or damage the fingerprint r...

Страница 5: ...omponents may differ dependingon where the product is installed Note BioLite Net Main bracket Extension bracket Mounting screws for bracket 2 pcs PVC anchors 2 pcs Heat shrink tubes TCP IP connector H...

Страница 6: ...every 2 seconds The IP address has not been received via DHCP in Device IP configuration Blue and sky blue alternate flashing every 2 seconds Normal operation Red and pink alternative flashing every 2...

Страница 7: ...G D0 Green 6 WG D1 White 7 WG GND Black 8 ENET RXN Yellow 9 ENET RXP Blue 10 ENET TXN Orange 11 ENET TXP Pink 12 RLY NC Orange White stripe 13 RLY COM Green White stripe 14 RLY NO Gray White stripe 15...

Страница 8: ...Precautions for registering afingerprint Registering a finger is the most important procedure because this device uses the registered fingerprint to compare it with a fingerprint that the device trie...

Страница 9: ...e with a drill and then insert a PVC anchor into the hole before inserting the mounting screw 2 Attach BioLite Net onto the mounted bracket 3 Assemble BioLite Net with the wall mount bracket by fasten...

Страница 10: ...for Secure I O 2 electric lock and BioLite Net respectively If connecting and using the power supply to these devices together the devices may malfunction Connecting to a Network TCP IP Connecting to...

Страница 11: ...device Fail Secure Lock To use fail secure lock connect N O terminal as shown below Normally there is no current flowing through the relay and the door is opened when the relay is activated by a curr...

Страница 12: ...ime that you want 5 Select Door Sensor and then press the OK button 6 Press the OK button after selecting the port that will be used to control the door sensor 7 Select Exit Button and then press the...

Страница 13: ...r other devices 1 Refer to the following figure for connecting 2 Set up the relay Please refer to How to configure a Relay Door button Door sensor Door Lock Input 0 Relay Input 1 4 3 12 13 2 1 BioLite...

Страница 14: ...rate because it reduces the signal level Upto 32devices can be connected via daisy chain 1master device and 31 otherdevices 2 Set up the relay Please refer to How to configure a Relay Connecting as a...

Страница 15: ...000 Max Template 1 N 10 000 Max Text Log 50 000 Interface TCP IP Yes RS 485 1ch Host or Slave Selectable Wiegand 1ch In or Out Selectable TTL Input 2 Inputs Relay 1 Relay Relay Voltage Max 24VDC Curre...

Страница 16: ...Product Specifications 16 Dimensions Extension bracket Diameter 4 5 Diameter 4 5 Diameter 3 5 Main bracket...

Страница 17: ...f not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular insta...

Страница 18: ...employees subsidiaries branches partners and distributors of Suprema are exempt from liability even when it is claimed that there is a significant fault in the design or production process and also t...

Страница 19: ...www supremainc com www supremainc com...

Отзывы: