Setting the Number of Callouts per Day
The Prophet can be jumper set to transmit the current data once every 8 hours, or once
every 24 hours. The first callout is set when the white button is pressed for a forced
transmission.
For instance:
The white button is pressed during commissioning at 9:00 am. For a transmission every
24 hours, an automatic reading will be transmitted every day at 9:00 am. For a
transmission every 8 hours, the reading will be transmitted at 9:00 am, 5:00 pm, and 1:00
am.
CAUTION:
If you set the number of calls to a number greater than the number of calls included in
your service agreement, then an additional fee will be charged for each call above
your allotment.
Jumpers J1 and J2 within the Prophet control the number of callouts. The table below
describes the four possible combinations:
J1
J2
OFF
OFF
One data transmission per 24 hours.
J1
J2
OFF
ON
One data transmission per 24 hours, plus data transmission upon a
3% change in product level based on sensor range.
J1
J2
ON
OFF
Three data transmissions per 24 hours.
J1
J2
ON
ON
One data transmission every hour. (for factory testing only)
Figure 12 illustrates the location of Jumpers J1 and J2.