![Supmeter BST100-B11 Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/supmeter/bst100-b11/bst100-b11_operation-manual_1406101059.webp)
58
6.4.7 Belt Length Calibration (LEnS)
Keep the belt weigher running at a constant speed. After the belt running time of a revolution being
measured by stopwatch, do this operation for correcting Belt Length.
RUN AUTO
EXT ALARM
kg
t
t/h
kg/m
Main Display Interface
【
MENU
】
+
【
▲
】
【
▼
】
:
≡
F2-CAL
≡
【
ENT
】
+
【
▲
】
【
▼
】
: --LEnS--
【
ENT
】
【
ENT
】
M
Input Running Time of a Revolution [s]
RUN AUTO
EXT ALARM
kg
t
t/h
kg/m
L: Belt Length Detected [m]
tI: Run-timer [s]
RUN AUTO
EXT ALARM
kg
t
t/h
kg/m
【
MENU
】
: Exit
【
ENT
】
: Save
M
Run-Timer over or
【
ENT
】
[P102]: Belt Length [m]
【
▲
】
【
▼
】
: Display Belt Length [L=] or Pulse Count [P=]
www.zemicusa.info
Содержание BST100-B11
Страница 72: ...71 User s Memo w w w z e m i c u s a i n f o...