background image

USER’S MANUAL

 

 

Revision 1.1

X9DRT-F

X9DRT-IBQF

X9DRT-IBFF

Содержание X9DRT-F

Страница 1: ...USER S MANUAL Revision 1 1 X9DRT F X9DRT IBQF X9DRT IBFF...

Страница 2: ...UCH DAMAGES IN PARTICULAR SUPER MICRO COMPUTER INC SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INS...

Страница 3: ...therboard is ideal for 1U Twin system platforms Please refer to our website http www supermicro com for processor and memory support updates Manual Organization Chapter 1 describes the features specif...

Страница 4: ...ent damaging your system or injuring yourself Warning Important information given to ensure proper system installation and to avoid damaging the components Note Additional information given to differe...

Страница 5: ...icro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Supp...

Страница 6: ...nstallation 2 5 Installing the LGA2011 Processor 2 5 Installing a Passive CPU Heatsink 2 9 Removing the Passive Heatsink 2 10 2 3 Installing and Removing the Memory Modules 2 11 Installing Removing DI...

Страница 7: ...SATA DOM Power Connector 2 31 IPMB I2 C SMB 2 32 Power SMB I2 C Connector 2 32 TPM Header Port 80 2 33 T SGPIO1 Header 2 33 2 7 Jumper Settings 2 34 Explanation of Jumpers 2 34 GLAN Enable Disable 2 3...

Страница 8: ...Asked Questions 3 7 3 5 Returning Merchandise for Service 3 8 Chapter 4 BIOS 4 1 Introduction 4 1 4 2 Main Setup 4 2 4 3 Advanced Setup Configurations 4 4 4 4 Event Logs 4 26 4 5 IPMI 4 28 4 6 Boot 4...

Страница 9: ...ality and performance This motherboard was designed to be used in an SMC proprietary system as a part of an integrated system platform Note For your system to work properly please follow the links bel...

Страница 10: ...therboard Image Note All graphics shown in this manual were based upon the latest PCB Revision available at the time of publishing of the manual The motherboard you ve received may or may not look exa...

Страница 11: ...tices please refer to http www supermicro com products nfo files IPMI Best_Practices_BMC_Security pdf Motherboard Layout X9DRT F Rev 1 01A USB0 1 IPMI_LAN LAN1 LAN2 COM1 VGA LEM1 JIB1 JBR1 InfiniBand...

Страница 12: ...SATA and front panel control connections X9DRT F IBQF IBFF Quick Reference X9DRT F Rev 1 01A USB0 1 IPMI_LAN LAN1 LAN2 COM1 VGA LEM1 JIB1 JBR1 InfiniBand UID LE2 LEB1 LEB2 JI2C2 JI2C1 JWD1 CPU1 PCI E...

Страница 13: ...Ports 0 1 SATA 2 0 Ports 2 5 J23 J24 20 Pin Main Power Connectors See Page 2 25 in Chapter 2 InfiniBand InfiniBand Connector X9DRT IBQF IBFF only JBAT1 Onboard CMOS Battery See Chapter 3 for Used Batt...

Страница 14: ...tatus LE1 Onboard PWR LED Green On Power On LE2 UID LED Blue On Unit Identified LEB1 LEB2 IBQF IBFF InfiniBand LED On IB On LEM1 BMC Heartbeat LED Green Blinking BMC Normal Note The X9DRT F IBQF IBFF...

Страница 15: ...s dependent on Intel E5 2600v2 CPUs Note 2 For the latest memory updates please refer to the Tested Memory List posted on our website http www supermicro com products motherboard Chipset Intel C602J P...

Страница 16: ...mechanism Keyboard Wake up from Soft Off Power on mode for AC power recovery PC Health CPU Monitoring Monitoring Onboard voltage monitors for 1 8V 3 3V 3 3VSB 5V Standby 1 35V 1 5V Chipset Voltage and...

Страница 17: ...sis and heatsink cooling restrictions For proper thermal management please check the chassis and heatsink specifications for proper CPU TDP sizing Note 2 For IPMI Configuration Instructions please ref...

Страница 18: ...models E5 2600 v2 E5 2600 v2 QPI DDR3 DIMM DDR3 DIMM DDR3 DIMM DDR3 DIMM 1 G SSB C602J PEG0 DMI PEG1_4 1 PEG1_8 PCI 32bit USB LAN i350 2 ports AT25321 IB FDR QDR LPC CPU FRONT FAN Side CPU REAR I O S...

Страница 19: ...0 GT s providing superb system performance and functionality enhancement The C602J chipset provides extensive IO support including the following func tions and capabilities PCI Express Rev 2 0 support...

Страница 20: ...an error message is sent to the screen The user can adjust the voltage thresholds to define the sensitivity of the voltage monitor Environmental Temperature Control A thermal management controller mo...

Страница 21: ...low Blinking LED for Suspend State Indicator When the CPU goes into a suspend state the chassis power LED will start blinking to indicate that the CPU is in suspend mode When the user presses any key...

Страница 22: ...for remote system management The WPCM450 Controller interfaces with the host system via PCI connections to communicate with the graphics cores It supports USB 2 0 and 1 1 for remote keyboard mouse vi...

Страница 23: ...d Media Independent Interface RMII OS Operating System Independency Provides remote Hardware Health Monitoring via IPMI Key features Provides Network Management Security via remote access console redi...

Страница 24: ...1 16 X9DRT F IBQF IBFF Motherboard User s Manual Notes...

Страница 25: ...omponents Read this section in its entirety before installing or configuring components in the Supermicro chassis Battery Handling Warning There is a danger of explosion if the battery is replaced inc...

Страница 26: ...de explosi n si la bater a se reemplaza de manera incorrecta Re emplazar la bater a exclusivamente con el mismo tipo o el equivalente recomen dado por el fabricante Desechar las bater as gastadas seg...

Страница 27: ...dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y regla mentos nacionales Attention L...

Страница 28: ...y do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistatic b...

Страница 29: ...e chassis before you install the CPU heatsink When receiving a motherboard without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent...

Страница 30: ...ose 1st to release the load plate that covers the CPU socket from its locking position 3 With the Close 1st lever fully retracted gently push down on the Open 1st lever to open the load plate Lift the...

Страница 31: ...not drop the CPU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket Socket Ke...

Страница 32: ...properly installed 5 Close the load plate with the CPU inside the socket Lock the Close 1st le ver first then lock the Open 1st lever second Use your thumb to gently push the load levers down to the l...

Страница 33: ...two screws on each side of the heatsink through the mounting holes on the motherboard and turn the push pins clockwise to lock them Notes 1 For optimized airflow please follow your chassis airflow dir...

Страница 34: ...crew on the heatsink and turn counter clock wise to loosen it Repeat the same step to loosen the second screw 3 Hold the heatsink as shown in the picture below and gently wriggle the heat sink to loos...

Страница 35: ...of the module straight down into the slot until the module snaps into place 5 Press the release tabs to the locking positions to secure the DIMM module into the slot Press both notches straight down i...

Страница 36: ...ponding Memory Modules CPU Corresponding DIMM Modules CPU 1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 CPU2 P2 DIMME1 P2 DIMMF1 P2 DIMMG1 P2 DIMMH1 Processor and Memory Module Population for Optimal Perf...

Страница 37: ...ite at http www supermicro com support resources mem cfm Populating RDIMM ECC Memory Modules Intel E5 2600 v2 Series Processor RDIMM Memory Support Ranks Per DIMM Data Width Memory Capacity Per DIMM S...

Страница 38: ...s mem cfm Populating RDIMM ECC Memory Modules Intel E5 2600 Series Processor RDIMM Memory Support Ranks Per DIMM Data Width Memory Capacity Per DIMM See the Note Below Speed MT s and Voltage Validated...

Страница 39: ...ks Per DIMM Data Width Memory Capacity Per DIMM See the Note Below Speed MT s and Voltage Validated by Slot per Channel SPC and DIMM Per Channel DPC 2 Slots Per Channel 3 Slots Per Channel 1DPC 2DPC 1...

Страница 40: ...t the locations of all the mounting holes for both motherboard and chassis match Although a chassis may have both plastic and metal mounting fas teners metal ones are highly recommended because they g...

Страница 41: ...assis as needed 5 Install the motherboard into the chassis carefully to avoid damaging mother board components 6 Using the Phillips screwdriver insert a Pan head 6 screw into a mounting hole on the mo...

Страница 42: ...2C2 JVRM_I2C1 JIPMB1 USB2 JPG1 JPL1 JPTM1 JPB1 JBAT1 CPU2 CPU1 SW1 PCH C602J BMC LAN CTRL IB CTRL Processor 1 Processor 2 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st JPME2 JPME1 2 5 Control Panel Connectors...

Страница 43: ...1 JBT1 JVRM_I2C2 JVRM_I2C1 JIPMB1 USB2 JPG1 JPL1 JPTM1 JPB1 JBAT1 CPU2 CPU1 SW1 PCH C602J BMC LAN CTRL IB CTRL Processor 1 Processor 2 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st JPME2 JPME1 Universal Seria...

Страница 44: ...low 3V3SB 5 TD1 14 Link 1000 LED Yellow 3V3SB 6 TD2 15 Ground 7 TD2 16 Ground 8 TD3 17 Ground 9 TD3 18 Ground NC No Connection 1 2 X9DRT F Rev 1 01A USB0 1 IPMI_LAN LAN1 LAN2 COM1 VGA LEM1 JIB1 JBR1...

Страница 45: ...PMB1 USB2 JPG1 JPL1 JPTM1 JPB1 JBAT1 CPU2 CPU1 SW1 PCH C602J BMC LAN CTRL IB CTRL Processor 1 Processor 2 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st JPME2 JPME1 1 2 Serial Ports A COM Port is located next...

Страница 46: ...rocessor 2 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st JPME2 JPME1 Pin Description 1 Ground 2 Transmitter Inverted Data Input 3 Transmitter Non Inverted Data Input 4 Ground 5 Transmitter Inverted Data Input...

Страница 47: ...link UID Switch Pin Definition 1 Ground 2 Ground 3 Button In 4 Ground UID Switches LEDs Description Location FP Switch Pin 13 on JF1 Rear Switch SW1 FP UID LED Blue LED Pin 8 on JF1 Rear UID LED LE2 1...

Страница 48: ...et Button 2 Power Fail LED HDD LED FP PWRLED Reset PWR 3 3 V ID_UID_SW 3 3V Stby Red Blue LED Cathode Ground Ground 19 20 3 3V X Ground NMI X NIC2 Link LED NIC2 Activity LED NIC1 Activity LED X9DRT F...

Страница 49: ...finitions NMI Button Pin Definitions JF1 Pin Definition 19 Control 20 Ground Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 PWR LED Front Control Panel Pin Definitions A NMI B PWR LED A B X9D...

Страница 50: ...for GLAN Port 2 is on pins 9 and 10 Attach the NIC LED cables here to display network activity Refer to the table on the right for pin definitions A HDD LED ID_UID SW PWR Standby B NIC1 Link Activity...

Страница 51: ...or power failure The Blue LED on pin 8 works as the front panel UID LED indicator The Red LED takes precedence over the Blue LED by default Refer to the tables on the right for pin definitions OH Fan...

Страница 52: ...tions Power Button Pin Definitions JF1 Pin Definition 1 Signal 2 Ground Reset Button The Reset Button connection is located on pins 3 and 4 of JF1 Attach it to a hardware reset switch on the computer...

Страница 53: ...connector JP8 are located on the motherboard These power con nectors meet the SSI EPS 12V specification For power supply to work properly please follow the instructions given below See the table on t...

Страница 54: ...PCH C602J BMC LAN CTRL IB CTRL Processor 1 Processor 2 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st JPME2 JPME1 A JP8 Right 4 Pin PWR Cable A 4 pin Auxiliary Power Connector In addition to two 20 pin power...

Страница 55: ...t OPEN 1st CLOSE 1st OPEN 1st JPME2 JPME1 A Fan 1 B Fan 3 C Fan 4 D SATA DOM PWR C D Fan Headers This motherboard has three system CPU fan headers Fan 1 Fan 3 and Fan 4 on the motherboard All these 4...

Страница 56: ...JPB1 JBAT1 CPU2 CPU1 SW1 PCH C602J BMC LAN CTRL IB CTRL Processor 1 Processor 2 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st JPME2 JPME1 A IPMB B PWR SMB JPI2 C1 A IPMB I2 C SMB A System Management Bus head...

Страница 57: ...r Port 80 A Trusted Platform Module Port 80 head er is located at JTPM1 to provide TPM support and Port 80 connection Use this header to enhance system performance and data security See the table on t...

Страница 58: ...E2 JPME1 2 7 Jumper Settings Explanation of Jumpers To modify the operation of the mother board jumpers can be used to choose between optional settings Jumpers cre ate shorts between two pins to chang...

Страница 59: ...ject such as a small screwdriver to touch both pads at the same time to short the connection Always remove the AC power cord from the system before clearing CMOS Note 1 For an ATX power supply you mus...

Страница 60: ...PCH C602J BMC LAN CTRL IB CTRL Processor 1 Processor 2 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st JPME2 JPME1 A VGA Enabled B BMC Enabled VGA Enable Jumper JPG1 allows the user to en able the onboard VGA c...

Страница 61: ...OSE 1st OPEN 1st JPME2 JPME1 A JI2 C1 JI2 C2 B IB Enabled IB Enable X9DRT IBQF IBFF Only Use Jumper JIB1 to enable or disable the onboard InfiniBand support on the X9DRT IBQF IBFF See the table on the...

Страница 62: ...c ture Mode allowing the user to flash the system firmware from a host server for system setting modifications See the table on the right for jumper settings ME Mode Select Jumper Settings Jumper Sett...

Страница 63: ...ard The amber LED on the right indicates activity while the green LED on the left indicates the speed of the con nection See the tables at right for more information LAN 1 LAN 2 IPMI LAN X8ST3 F Link...

Страница 64: ...ED B Rear UID LED A B Onboard Power LED An Onboard Power LED is located at LE1 on the motherboard When this LED is on the system is on Be sure to turn off the system and unplug the power cord before r...

Страница 65: ...Act LED BMC Heartbeat LED Status Color State Definition Green Blinking BMC Normal BMC Heartbeat LED A BMC Heartbeat LED is located at LEM1 on the motherboard When LEM1 is blinking BMC functions norma...

Страница 66: ...RL P1 DIMMC1 P1 DIMMD1 T SGPIO1 JBT1 JVRM_I2C2 JVRM_I2C1 JIPMB1 USB2 JPG1 JPL1 JPTM1 JPB1 JBAT1 CPU2 CPU1 SW1 PCH C602J BMC LAN CTRL IB CTRL Processor 1 Processor 2 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1...

Страница 67: ...2 JPG1 JPL1 JPTM1 JPB1 JBAT1 CPU2 CPU1 SW1 PCH C602J BMC LAN CTRL IB CTRL Processor 1 Processor 2 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st JPME2 JPME1 A A I SATA0 3 0 B I SATA1 3 0 C I SATA2 2 0 D I SATA...

Страница 68: ...2 44 X9DRT F IBQF IBFF Motherboard User s Manual Notes...

Страница 69: ...the motherboard and chassis 2 Disconnect all ribbon wire cables from the motherboard including keyboard and mouse cables 3 Remove all add on cards 4 Install CPU 1 first making sure it is fully seated...

Страница 70: ...gging the power cord and contacting both pads on the CMOS Clear Jumper JBT1 Refer to Sec tion 2 8 in Chapter 2 2 Remove all components from the motherboard especially the DIMM mod ules Make sure that...

Страница 71: ...mong all memory slots and check the results 5 Make sure that all memory modules are fully seated in their slots Follow the instructions given in Section 2 4 in Chapter 2 6 Please follow the instructio...

Страница 72: ...operly including boot devices such as CD DVD disc CD DVD ROM 2 Cable connection Check to make sure that all cables are connected and working properly 3 Using minimum configuration for troubleshooting...

Страница 73: ...s chapter or see the FAQs on our website http www supermicro com before contacting Technical Support 2 BIOS upgrades can be downloaded from our website http www supermicro com 3 If you still cannot re...

Страница 74: ...the steps 1 2 above and continue below 2 Identify the battery s polarity The positive side should be facing up 3 Insert the battery into the battery holder and push it down until you hear a click to e...

Страница 75: ...loading You can choose from the zip file and the exe file If you choose the zip BIOS file please unzip the BIOS file onto a bootable USB device Run the batch file using the format AMI bat filename rom...

Страница 76: ...ominently displayed on the outside of the shipping carton and the shipping package is mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed wh...

Страница 77: ...l the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reser...

Страница 78: ...can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade the BIOS unless your syste...

Страница 79: ...ields The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X9DRT Version Th...

Страница 80: ...al POST messages The op tions are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Current to use the current AddOn ROM Display setting...

Страница 81: ...tem to automatically reboot when a non recoverable error occurs that lasts for more than five minutes The options are Enabled and Disabled Power Button Function If this feature is set to Instant Off t...

Страница 82: ...g Technology Intel VT x Technology Intel SMX Technology L1 Data Cache L1 Code Cache L2 Cache L3 Cache CPU Speed This item displays the speed of the CPU installed in Socket 1 Socket 2 64 bit This item...

Страница 83: ...cannot thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damage the system during an attack The default is Enabled Refer to Intel and Microsoft Web sites for...

Страница 84: ...uration This submenu allows the user to configure the following CPU Power Management settings Power Technology Select Energy Efficient to support power saving mode Select Custom to cus tomize system p...

Страница 85: ...ate limit Available when Power Technology is set to Custom This feature allows the user to set the limit on the C State package register The options are C0 C2 C6 and No Limit Energy Performance Bias U...

Страница 86: ...O device assignments to the VMM Virtual Machine Monitor through the DMAR ACPI Tables This feature offers fully protected I O resource sharing across Intel platforms providing greater reliability secur...

Страница 87: ...e port Select GEN3 to enable PCI Exp Generation 3 support for the port The options are GEN1 GEN2 and GEN3 IIO 2 PCIe Port Bifurcation Control This submenu configures the following IO PCIe Port Bifurca...

Страница 88: ...tem performance DIMM Information The status of the memory modules detected by the BIOS is displayed Memory Mode When Independent is selected all DIMMs are available to the operating system When Mirror...

Страница 89: ...ub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module When the CPU or I O issues a demand read command and the read data from memory turns...

Страница 90: ...uto to disable legacy sup port if USB devices are not present Select Disabled to have USB devices available for EFI Extensive Firmware Interface applications only The settings are Disabled Enabled and...

Страница 91: ...TA AHCI controller manages the power usage of the SATA link The controller will put the link in a low power mode during extended periods of I O inactivity and will return the link to an active state w...

Страница 92: ...nd Disabled SERR Generation Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus Signal Error Event The options are Enabled and Disabled Maximum Payload Select Auto to allow t...

Страница 93: ...to boot the computer using a network device The default setting for LAN1 Option ROM is Enabled and the default setting for LAN2 Option ROM is Disabled VGA Priority This feature allows the user to sel...

Страница 94: ...ed to enable a serial port specified by the user The options are Enabled and Disabled Device Settings This item displays the settings of Serial Port 2 SOL Change Settings This option specifies the bas...

Страница 95: ...de characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per second Use this feature to set the transmission speed for a serial port used in Console Redirection Make sure...

Страница 96: ...nabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolutio...

Страница 97: ...Con sole Redirection Select VT100 to use the ASCII character set Select VT100 to add color and function key support Select ANSI to use the extended ASCII character set Select VT UTF8 to use UTF8 enco...

Страница 98: ...options are Enabled and Disabled High Precision Event Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real tim...

Страница 99: ...PM is currently enabled or disabled TPM Active Status This item displays the status of TPM Support to indicate if TPM is currently ac tive or deactivated TPM Owner Status This item displays the status...

Страница 100: ...rt TPM State Trusted Platform state ME Subsystem This feature displays the following ME Subsystem Configuration settings ME BIOS Interface Version ME Version iSCSI Configuration This item displays iSC...

Страница 101: ...s Full 100Mbps Half and 100Mbps full Wake on LAN Select enabled to wake the system with a magic packet The options are En abled and Disabled Blink LEDs This feature allows the user to specify the dura...

Страница 102: ...ble SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are En...

Страница 103: ...OS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Count Increment Enter the increment value for the...

Страница 104: ...m reboot Select Yes On every reset to erase all system event logs upon each system reboot Select No to keep all system event logs after each system reboot The options are No Yes On next reset and Yes...

Страница 105: ...d to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected the BIOS will search for a DHCP Dynamic Host Configuration Protocol server in the network...

Страница 106: ...Network Devices Hard Disk Drives The above options appear when detected by the BIOS Use these options to set the order of the legacy network and Hard Disk Drive devices detected by the motherboard Ad...

Страница 107: ...ry is required Select Setup to require the password only when entering setup Select Always to require the pass word when entering setup and on each boot The options are Setup and Always Administrator...

Страница 108: ...ve Changes and Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration settings can take effe...

Страница 109: ...is feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults select Yes to save the current value...

Страница 110: ...4 34 X9DRT F IBQF IBFF Motherboard User s Manual Notes...

Страница 111: ...cturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding er...

Страница 112: ...A 2 X9DRT F IBQF IBFF Motherboard User s Manual Notes...

Страница 113: ...storage driver diskette by booting into a Driver CD please set the SATA Configuration to Compatible Mode and configure SATA as IDE in the BIOS Setup After making the driver diskette be sure to change...

Страница 114: ...elow for a display of the SuperDoctor III interface Note 1 The default user name and password are ADMIN Note 2 In the Windows OS environment the SuperDoctor III settings take precedence over the BIOS...

Страница 115: ...III Interface Display Screen II Remote Control Note SD III software and the user guide can be downloaded from our website at http www supermicro com products accessories software SuperDoctorIII cfm F...

Страница 116: ...B 4 X9DRT F IBQF IBFF Motherboard User s Manual Notes...

Страница 117: ...expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in su...

Отзывы: