Chapter 4: AMI BIOS
4-15
Remote Access Configuration
Remote Access
This feature allows the user to enable the function of Remote Access. The options
are
Disabled
and Enabled.
If the item Remote Access is set to Enabled, the following items will display:
Serial Port Number
This feature allows the user decide which serial port to be used for Console
Redirection. The options are COM 1, and COM 2.
Serial Port Mode
This feature allows the user to set the serial port mode for Console Redirection.
The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and
9600 8, n, 1.
Flow Control
This feature allows the user to set the flow control for Console Redirection. The
options are
None,
Hardware, and Software.
Redirection After BIOS POST
Select Disabled to turn off Console Redirection after Power_On_Self_Test
(POST). Select Always to keep Console Redirection active all the time after
POST. (Note: This setting may not be supported by some operating systems.)
Select Boot Loader to keep Console Redirection active during POST and Boot
Loader. The options are Disabled, Boot Loader, and
Always
.
Terminal Type
This feature allows the user to select the target terminal type for Console Redi-
rection. The options are
ANSI
, VT100, and VT-UTF8.
VT-UTF8 Combo Key Support
A terminal keyboard definition that provides a way to send commands from a
remote console. Available options are
Enabled
and Disabled.
Sredir Memory Display Delay
This feature defines the length of time in seconds to display memory information.
The options are
No Delay
, Delay 1 Sec, Delay 2 Sec, and Delay 4 Sec.
Содержание X7SLA-H
Страница 1: ...X7SLA L USER S MANUAL Revision 1 0a X7SLA H...
Страница 50: ...3 6 X7SLA L X7SLA H User s Manual Notes...
Страница 70: ...4 20 X7SLA L X7SLA H User s Manual Notes...
Страница 72: ...A 2 X7SLA L X7SLA H User s Manual Notes...
Страница 78: ...C 4 X7SLA L X7SLA H User s Manual Notes...