7-18
S
UPERSERVER 6035B-8R+ User’s Manual
Hardware Monitor Logic
CPU Temperature Threshold
This option allows the user to set a CPU temperature threshold that will activate
the alarm system when the CPU temperature reaches this pre-set temperature
threshold. The options are 70
o
C, 75
o
C,
80
o
C
and 85
o
C.
Highlight this and hit <Enter> to see monitor data for the following items:
CPU1 Temperature
: This item displays CPU1 Temperature.
CPU2 Temperature
: This item displays CPU2 Temperature.
LM93 Temperature
: This item displays LM93 Temperature.
Fan 1-FAN8
: If the feature of Auto Fan Control is enabled, the BIOS will automatically
display the status of the fans indicated in this item.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase, and vise versa.
If the option is set to “3-pin fan”, the fan speed is controlled by voltage. If the
option is set to “4-pin”, the fan speed will be controlled by Pulse Width Modulation
(PWM). Select “3-pin” if your chassis came with 3-pin fan headers. Select “4-pin” if
your chassis came with 4-pin fan headers. Select “Workstation” if your system is
used as a Workstation. Select “Server” if your system is used as a Server. Select
“Disable” to disable the fan speed control function to allow the onboard fans to
run at the full speed (12V) at all the time. The Options are:
1. Disable
, 2. 3-pin
(Server), 3. 3-pin (Workstation), 4. 4-pin (Server) and 5. 4-pin (Workstation).
Voltage Monitoring
The following items will be monitored and displayed:
P12V_VR0
P12V_VR1
FSB VTT
PXH Vcore
ES2B Vcore
CPU1Vcore
CPU2Vcore
P3V3
Содержание SUPERSERVER 6035B-8R+
Страница 1: ... SUPERSERVER 6035B 8R SUPER USER S MANUAL 1 0 ...
Страница 5: ...v Preface Notes ...
Страница 10: ...Notes x SUPERSERVER 6035B 8R User s Manual ...
Страница 23: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Server into a Rack ...
Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System ...
Страница 30: ...SUPERSERVER 6035B 8R User s Manual 3 4 Notes ...
Страница 62: ...5 28 SUPERSERVER 6035B 8R User s Manual Notes ...
Страница 72: ...6 10 SUPERSERVER 6035B 8R User s Manual Figure 6 6 Replacing a Power Supply Module ...
Страница 100: ...A 6 SUPERSERVER 6035B 8R User s Manual Notes ...
Страница 106: ...B 6 SUPERSERVER 6035B 8R User s Manual Notes ...
Страница 110: ...C 4 SUPERSERVER 6035B 8R User s Manual Notes ...