6-4 System Fans
The SC829BTQ chassis contains four 8-cm high-performance fans.
System Fan Failure
Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining
fan will ramp up to full speed and the overheat/fan fail LED on the control panel will
turn on. Replace any failed fan at your earliest convenience with the same type and
model (the system can continue to run with a failed fan).
Remove the top chassis cover while the system is still running to determine which of
the fans has failed. Then power down the system before replacing a fan. Removing
the power cord(s) is also recommended as a safety precaution.
Replacing System Fans
1. After determining which fan has failed, turn off the system power.
2. Unplug the fan wiring from the serverboard and remove the failed fan.
3. Press the fan release tab to lift the failed fan from the chassis and pull it
completely from the chassis.
4. Place the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
5. Power up the system and check that the fan is working properly before re-
placing the chassis cover.
Содержание SUPERSERVER 6027AX-72RF
Страница 1: ...SUPERSERVER 6027AX TRF 6027AX 72RF SUPER USER S MANUAL 1 0...
Страница 5: ...v Preface Notes...
Страница 14: ...1 6 SUPERSERVER 6027AX TRF 6027AX 72RF User s Manual Notes...
Страница 22: ...2 8 SUPERSERVER 6027AX TRF 6027AX 72RF User s Manual Notes...
Страница 26: ...3 4 SUPERSERVER 6027AX TRF 6027AX 72RF User s Manual Notes...
Страница 46: ...4 20 SUPERSERVER 6027AX TRF 6027AX 72RF User s Manual Notes...
Страница 122: ...A 2 SUPERSERVER 6027AX TRF 6027AX 72RF User s Manual Notes...
Страница 125: ...B 3 Appendix B System Specifications Notes...