3-2
S
UPER
S
ERVER 6016T-URF/6016T-UF/6016T-NTRF/6016T-NTF User's Manual
Power
The main power button is used to apply or remove power from the power supply
to the server system. Turning off system power with this button removes the main
power but keeps standby power supplied to the system.
3-3 Control Panel LEDs
The control panel located on the front of the SC815TS-R560U/SC815TS-560UBP
chassis has
fi
ve LEDs. These LEDs provide you with critical information related to
different parts of the system. This section explains what each LED indicates when
illuminated and any corrective action you may need to take.
Figure 3-1. Universal Information LED States
Universal Information LED States
State Indication
Fast Blinking Red (1x/sec)
Fan Fail
Solid Red
CPU Overheat
Slow Blinking Red (1x/4 sec)
Power Fail
Solid Blue
Local UID Button Depressed
Blinking Blue
IPMI-Activated UID
Note:
deactivating the UID LED must be performed in the same way it was activated.
(If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and
not with the UID button.)
Universal Information LED
When this LED blinks red quickly, it indicates a fan failure and when blinking red
slowly a power failure. The LED will be blue when used for UID (Unit Identi
fi
er).
When on continuously it indicates an overheat condition, which may be caused by
cables obstructing the air
fl
ow in the system or the ambient room temperature being
too warm. Check the routing of the cables and make sure all fans are present and
operating normally. You should also check to make sure that the chassis covers
are installed. Finally, verify that the heatsinks are installed properly (see Chapter
5). This LED will remain
fl
ashing or on as long as the indicated condition exists.
See the table below for descriptions of the LED states.
Содержание SUPERSERVER 6016T-NTF
Страница 5: ...v Preface Notes...
Страница 48: ...4 20 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Страница 76: ...5 28 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Страница 87: ...Chapter 6 Advanced Chassis Setup 6 11 Figure 6 6 Removing Replacing the Power Supply...
Страница 88: ...6 12 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...
Страница 114: ...A 2 SUPERSERVER 6016T URF 6016T UF 6016T NTRF 6016T NTF User s Manual Notes...