7-14
SUPERSERVER 2028TP-HC1R/HC1TR/HC1FR USER'S MANUAL
Data Scrambling
Select Enabled to enable data scrambling to enhance system performance and
data integrity. The options are
Auto
, Disabled and Enabled.
DRAM RAPL (Running Average Power Limit) Baseline
Use this feature to set the run-time power-limit baseline for DRAM modules. The
options are Disable, DRAM RAPL Mode 0, and
DRAM RAPL Mode 1
.
Set Throttling Mode
Throttling improves reliability and reduces power consumption in the proces-
sor via automatic voltage control during processor idle states. The options are
Disabled and
CLTT
(Closed Loop Thermal Throttling).
Socket Interleave Below 4GB
Select Enable for the memory above the 4G Address space to be split between
two sockets. The options are Enable and
Disable
.
Channel Interleaving
Use this item to set DIMM channel interleaving mood. The options are
Auto
,
1-Way Interleave, 2-Way Interleave, 3-Way Interleave, and 4-Way Interleave.
Rank Interleaving
Use this item to select a rank memory interleaving method. The options are
Auto
,
1-Way, 2-Way, 4-Way, and 8-Way.
A7 Mode
Select Enable to support the A7 (Addressing) mode to improve memory perfor-
mance. The options are
Enable
and Disable.
DIMM Information
This item displays the status of a DIMM module as detected by the AMI
BIOS.
Memory RAS (Reliability_Availability_Serviceability)
Configuration
Use this submenu to configure the following Memory RAS settings.
RAS Mode
When Disable is selected, RAS is not supported. When Mirror is selected, the
motherboard maintains two identical copies of all data in memory for data backup.
When Lockstep is selected, the motherboard uses two areas of memory to run
Содержание SUPERSERVER 2028TP-HC1FR
Страница 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 2028TP HC1R 2028TP HC1TR 2028TP HC1FR...
Страница 5: ...v SUPERSERVER 2028TP HC1R HC1TR HC1FR USER S MANUAL Notes...
Страница 10: ...x Notes SUPERSERVER 2028TP HC1R HC1TR HC1FR USER S MANUAL...
Страница 18: ...1 8 SUPERSERVER 2028TP HC1R HC1TR HC1FR USER S MANUAL Notes...
Страница 30: ...SUPERSERVER 2028TP HC1R HC1TR HC1FR USER S MANUAL 3 4 Notes...
Страница 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Страница 87: ...Chapter 6 Advanced Chassis Setup 6 13 Figure 6 11 Installing the Serverboard in the Serverboard Node Drawer...
Страница 136: ...A 2 SUPERSERVER 2028TP HC1R HC1TR HC1FR USER S MANUAL Notes...
Страница 139: ...B 3 Appendix B System Specifications Notes...