background image

SC819 Chassis Manual

4-6

4-6 Overheating

The section lists actions that should be taken in the unlikely event the server 
overheats.

Overheat Temperature Setting

Some backplanes allow the overheat temperature to be set at 45, 50, or 55 degrees 
Farenheit by changing a jumper setting. For more backplane information, see the  
appendix at the back of this manual or download the backplane user manual at 
www.supermicro.com. To access the manuals on the Website, click Support, and 
then click the Manuals link.

Overheating Condition

If the server overheats, do the following:

1.  Use the LEDs to determine the nature of the overheating condition.

2. 

Confirm that the chassis covers are installed properly.

3.  Check the routing of the cables and make sure all fans are present and oper-

ating normally. 

4.  Verify that the heatsinks are installed properly.

Содержание SC819 Series

Страница 1: ...SC819 Chassis Series SC819TQ R700UB SC819TQ R700WB USER S MANUAL 1 0b SUPER ...

Страница 2: ...RDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of California County of Santa Clara shall be the exclusive venue for the resolution o...

Страница 3: ...ormed by experienced technicians only Supermicro s SC819 1U chassis features a unique and highly optimized design for 1U UIO servers The chassis is equipped with a 700W high efficiency 80 Plus Gold Level certified power supply to support high performance system components and high speed heavy duty counter rotating fans for ample cooling The chassis provides maximum features in a 1U form factor for...

Страница 4: ...ils on the system interface which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system Chapter 5 Chassis Setup and Installation This chapter provides detailed information on this chassis You should follow the procedures given in this chapter when installing removing or reconfiguring your chassis Chapter 6 Rack Insta...

Страница 5: ...Statements for AC Systems 2 1 About Standardized Warning Statements 2 1 Warning Definition 2 1 Installation Instructions 2 4 Circuit Breaker 2 5 Power Disconnection Warning 2 6 Equipment Installation 2 8 Restricted Area 2 9 Battery Handling 2 10 Redundant Power Supplies 2 12 Backplane Voltage 2 13 Comply with Local and National Electrical Codes 2 14 Product Disposal 2 15 Hot Swap Fan Warning 2 16 ...

Страница 6: ...allation 5 6 5 5 Installing the Motherboard 5 7 Permanent and Optional Standoffs 5 7 Expansion Card Setup 5 9 5 6 Installing the Air Shroud Optional 5 11 5 7 System Fans 5 12 5 8 Power Supply 5 14 Power Supply Failure 5 14 5 9 Routing the I2 C Cables 5 15 Chapter 6 Rack Installation 6 1 Overview 6 1 6 2 Unpacking the System 6 1 6 3 Preparing for Setup 6 1 Choosing a Setup Location 6 1 Rack Precaut...

Страница 7: ...vii Preface Optional Inner Rail Extensions 6 5 Appendix A Chassis Cables Appendix B SC819 Power Supply Specifications Appendix C SAS 815TQ Backplane Specifications ...

Страница 8: ...SC819 Chassis Manual viii Notes ...

Страница 9: ...bays offer maximum storage capacity in a 1U form factor 1 2 Shipping List Please visit the Supermicro web site at www supermicro com for the latest shipping lists and part numbers for your particular chassis model Chapter 1 Introduction 1 1 SC819 Chassis Model HDD I O Slots Power Supply SC819TQ R700UB 4x SAS SATA 2x FH 1x LP 700W Gold Level SC819TQ R700WB 4x SAS SATA 2x FH 1x LP 700W Gold Level Le...

Страница 10: ...up correctly these drives can be removed without power ing down the server Additionally these drives support SES2 PCI Expansion Slots Each version of the SC819 chassis includes two full height full length PCI expan sion slots and one low profile PCI expansion slot U and W versions are opti mized for UIO and WIO motherboards Peripheral Drives Each SC819 chassis supports one slim DVD ROM drive optio...

Страница 11: ...ess Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 23511 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226...

Страница 12: ...must be mailed when service is complete For faster service RMA authorizations may be requested online http www supermicro com support rma Whenever possible repack the chassis in the original Supermicro carton using the original packaging material If these are no longer available be sure to pack the chassis securely using packaging material to surround the chassis so that it does not shift within t...

Страница 13: ... configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preve...

Страница 14: ...o que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés aux circuits é...

Страница 15: ... aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES ً ف اًك أى ٌوكي حالة ً ف تتسبب اصابة جسذٌة الزهز هذا ًٌ ٌع خطز ...

Страница 16: ...ción antes de conectar el sistema a la red de alimentación Attention Avant de brancher le système sur la source d alimentation consulter les directives d installation 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい ال إرشادات اقر تركيب توصيل قبل إلى النظام للطاقة مصدر לקרוא יש למקור המערכת חיבור לפני התקנה הוראות את מתח 시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructies voordat u h...

Страница 17: ...liza el sistema de protección contra cortocircuitos o sobrecorrientes del edificio Asegúrese de que el dispositivo de protección no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit dépend de l installation électrique du local Vérifiez que le courant nominal du dispositif de protection n est pas supérieur à 250 V 20 A על מסתמך זה ...

Страница 18: ... es auf den Chassisinnenraum zurückgreift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록 해야 합니다 Waarsc...

Страница 19: ... ou enlever des composants de systéme חשמלי ניתוק מפני אזהרה אזהרה החשמל מקורות מכל המערכת את לנתק יש להסיר ויש מהספק החשמלי כבל את התקנ לצורך המארז של הפנימי לחלק גישה לפני ת הסר או ת רכיבים فصم يجب اننظاو جميع من مصادر انطاقت وإزانت انكهرباء سهك من وحدة امداد انطاقت قبم إنى انىصىل انداخهيت انمناطق ن ههيكم إزانت أو نتثبيج مكىناث الجهاز 경고 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터 연결...

Страница 20: ...et werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés אזהרה רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת או הציוד والمدربيه و لتزكيب استبدال أو خدمة الجهاس هذا يسمح أن يجب فقط ا...

Страница 21: ... in Bereichen mit beschränktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich Advertencia Esta unidad ha sido diseñada para instalación en áreas de acceso restringido Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial cerradura con lla...

Страница 22: ...ىص َمكن ً إن ىل منطقت محظورة فقط استخذاو خالل من خاصت أداة أو ٌ أ نال أخري وسُهت مألما ومفتاح قفم 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleut...

Страница 23: ...ipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante אזהרה סכנת קיימת פיצוץ תקינה לא בדרך והוחלפה במידה הסוללה של להחליף יש בסוג הסוללה את מ התואם חברת מומל יצרן צת הסוללות סילוק המשומשות לבצע יש היצרן הוראות לפי خطر هناك من اسحبذال حالة في انفجار البطارية صحيحة غير بطريقة فعليل البطارية اسحبذال فقط النىع بنفس يعادلها ما أو مما أو...

Страница 24: ...té peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées Redundant Power Supplies Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります ユニッ トの電源を切るためには すべての接続を取り外さなければなりませ...

Страница 25: ...idado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing قد لهذا يكون ال جهاز اتصاالت عدة بوحدات الطاقة امداد إزالة يجب االتصاالت كافة لعسل ال وحدة عن الكهرباء...

Страница 26: ...be cumplir con las normas de electricidad locales y nacionales هناك خطز مه الكهزبائي التيار على المىجىدة أوالطاقة اللىحة يكىن عندما النظام يعمل عند حذرا كه خدمة الجهاس هذا 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhou...

Страница 27: ...اويه والىطىية المحلية المتعلقة بالكهرباء Attention L équipement doit être installé conformément aux normes électriques nationales et locales 경고 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다 Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften 製品の廃棄 この製品を廃棄処分する場合 国の関係する全ての法律 条例に従い処理する必要が あります 警告 本产品的废弃处理应根据所有国家的法律和规章进行 警告 本產品的廢棄處理應根據所有國家的法律和規...

Страница 28: ...nt Renseignez vous auprès de l organisme compétent Warning The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing Hot Swap Fan Warning המוצר סילוק אזהרה ו להנחיות בהתאם להיות חייב זה מוצר של סופי סילוק המדינה חוקי النهائي التخلص من المنتج هذا معه التعامل ينبغي ل وفقا جميع الى...

Страница 29: ...rde à ce que doigts tournevis et autres objets soient éloignés du logement du bloc ventilateur אזהרה חלקי את מסירים כאשר יש עובדים עדיין והמאווררים יתכן מהמארז המאוורר להרחיק ל המאוורר בתוך מהפתחים שונים עבודה וכלי האצבעות את בטוח מרחק انممكه مه انمراوح أن تسال ال إزانة تدورعند كتهة انمروحة انهيكم مه يجب إبقاء األصابع و انبراغي مفكات األشياء مه وغيرها بعيدا عه انفتحات في كتهة انمروحة 경고 섀시로부터 팬 조립...

Страница 30: ... Code für alle anderen elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben Advertencia Al instalar el producto utilice los cables de conexión previstos o designados los cables y adaptadores de CA La utilización de otros cables y adaptadores podría ocasionar un mal funcionamiento o un incendio Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe el uso de UL o CSA...

Страница 31: ...צוין שלא تركيب عىذ استخذام يجب الجهاز و التىصيل كابالث الكهربائيت الكابالث ومحىالث المتردد التيار أن أي استخذام كابالث ومحىالث أخري يتسبب في عطل حذوث حريق أو التي لك تىفيرها تم المىتج مع UL أو CSA الكهربائيت األجهسة ومىاد قاوىن السالمت استخذام يحظر الكابالث قبل مه معتمذة Supermicro أجهسة أخري كهربائيت غير المىتجاث المعيىت قبل مه ألي UL CSA تحمل التي عالمت 경고 제품을 설치할 때에는 제공되거나 지정된 연결케이블과 전원케이블 AC어댑...

Страница 32: ...2 20 SC819 Chassis Manual Notes ...

Страница 33: ... at http www supermicro com Backplane Each SC819 chassis comes with a 1U backplane The backplane will accept SAS SATA hard drives For more information regarding compatible backplanes view the appendices found at the end of this manual In addition visit our Web site for the latest information http www supermicro com Fans The SC819 chassis accepts five system fans with an optional sixth fan System f...

Страница 34: ... usually made of plastic which funnels air directly to where cooling is needed 3 3 Where to get Replacement Components Although not frequently you may need replacement parts for your system To ensure the highest level of professional service and technical support we strongly recommend purchasing exclusively from our Supermicro Authorized Distributors System Integrators Resellers A list of Supermic...

Страница 35: ...ew There are several LEDs on the control panel and on the drive carriers that provide system and component status This chapter explains the meanings of all LED indi cators and the appropriate responses that may need to be taken Figure 4 1 Control Panel Buttons and LEDs ...

Страница 36: ... system before servicing Reset The reset button is used to reboot the system 4 2 Control Panel Buttons The SC819 chassis includes two or three push buttons located on the front panel a reset button a power on off button and a UID button UID When used with a UID compatible motherboard the UID button is used to turn on or off the blue light function of the the U LED Once the blue light is activated ...

Страница 37: ...y it indicates a fan failure and when blinking red slowly a power failure This LED will be blue when used for UID Unit Identifier When on continuously red it indicates an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm See the table below for descriptions of the LED states Figure 4 2 Universal Information LED Sta...

Страница 38: ... supply units This LED should normally be illuminated when the system is operating HDD Indicates IDE channel activity SAS SATA drive and or DVD ROM drive activ ity when flashing NIC1 Indicates network activity on GLAN1 when flashing NIC2 Indicates network activity on GLAN2 when flashing ...

Страница 39: ...e red LED to indicate an SAS SATA drive failure If one of the SAS SATA drives fail you should be notified by your system management software 4 5 Power Supply LEDs and Overheat Indicators The SC819 chassis is equipped with LED indicators to keep you informed of the system s status Solid Green When illuminated this green LED indicates that the power supply is on Solid Amber When illuminated the ambe...

Страница 40: ... the appendix at the back of this manual or download the backplane user manual at www supermicro com To access the manuals on the Website click Support and then click the Manuals link Overheating Condition If the server overheats do the following 1 Use the LEDs to determine the nature of the overheating condition 2 Confirm that the chassis covers are installed properly 3 Check the routing of the c...

Страница 41: ...the chassis The only tool needed to install components and perform maintenance is a Phillips screwdriver Print this page to use as a reference while setting up your chassis Review the warnings and precautions listed in the manual before setting up or servicing this chassis These include information in Chapter 2 System Safety and the warning precautions listed in the setup instructions ...

Страница 42: ...ar of the cover 3 Press the release tabs simultaneously 4 Slide the cover back toward the rear of the chassis 5 Lift the cover up and off of the chassis Warning Except for short periods of time do NOT operate the server without the cover in place The chassis cover must be in place to allow proper airflow and prevent overheating Figure 5 1 Removing the Chassis Cover Remove this screw 5 4 1 3 3 2 2 ...

Страница 43: ... that can be removed from the chassis and reinstalled without powering down the server Removing Hard Drive Carriers from the Chassis 1 Press the release button on the drive carrier which extends the drive carrier handle 2 Use the handle to pull the drive carrier out of the chassis Figure 5 2 Removing Hard Drive Carriers 1 2 ...

Страница 44: ...igure 5 3 Chassis Drive Carrier Installing a Hard Drive to the Hard Drive Carrier 1 Remove the two screws securing the dummy drive to the carrier 2 Remove the dummy drive from the carrier Warning Except for short periods of time while swapping hard drives do not oper ate the chassis without the drive carriers Figure 5 4 Removing a Dummy Drive from the Carrier Drive Carrier Dummy Drive 1 1 1 1 ...

Страница 45: ...es in the drive align with those in the carrier 4 Secure the hard drive by tightening all six screws 5 Return the drive carrier to the chassis drive bay Close the drive carrier handle to lock the drive into the drive bay Drive Carrier SAS SATA Hard Drive Figure 5 5 Removing the Hard Drive From the Carrier Figure 5 6 Replacing the Hard Drive Carrier 4 4 5 ...

Страница 46: ... from the motherboard and or back plane 5 If you are adding a new drive Remove the mini bezel grate from the drive bay The bezel can be removed by pulling out the hard drive beneath the DVD ROM or USB COM tray bay then pulling the mini bezel forward If you are replacing a drive Locate the locking tab at the rear left hand side when viewed from the front of the DVD ROM or USB COM tray Push the tab ...

Страница 47: ...he SC819 chassis includes permanent standoffs in locations used by most motherboards These standoffs accept the rounded Phillips head screws included in the SC819 accessories packaging Some motherboards require additional screws for heatsinks and or general compo nents Optional standoffs are included for these motherboards To use an optional standoff you must place the hexagonal screw through the ...

Страница 48: ...re the mounting holes on the motherboard to the mounting holes in the chassis then add or move standoffs to match the motherboard mounting hole locations B Place a hexagonal standoff screw through the bottom the chassis C Secure the screw with the hexagonal nut rounded side up 5 Lay the motherboard on the chassis aligning the permanent and optional standoffs 6 Secure the motherboard to the chassis...

Страница 49: ... a riser card to install expansion cards to any SC819 chassis Riser cards are sold separately For the latest compatibility and performance information visit our website at http www supermicro com Figure 5 9 One Low Profile Expansion Slot Figure 5 10 SC819 Two Full Height Full Length PCI slots and One Low Profile PCI slot Low Profile PCI Slot Full Height Full Length PCI Slots ...

Страница 50: ...ecure it using one of the two methods illustrated above For more information see the installation instructions included with the riser card 3 Choose the PCI slot in which to place the expansion card 4 In that slot open the PCI slot lever and slide the PCI slot cover sideways 5 From inside the chassis remove the PCI slot cover 6 Insert the expansion card card into the riser card and slide the expan...

Страница 51: ... uses between nine and sixteen DIMMS skip this step If your motherboard uses eight DIMMS you must remove the optional flap To do this a With the fan side facing you hold the air shroud with your left hand on the main shroud component and right hand on the optional flap b Gently twist with your right hand by lifting the fan side and lowering the other end of the optional flap 3 Place the air shroud...

Страница 52: ...onal open fan housing an additional system fan may be added for optimal cooling Adding a System Fan 1 Power down the system remove the power cords from the rear of the power supplies and remove the chassis cover as described in Section 5 3 2 Remove the dummy fan from the fan tray 3 Place the new fan into the vacant space in the fan tray while making sure the arrows on the top of the fan indicating...

Страница 53: ...he power cords from the rear of the power supplies and remove the chassis cover as described in Section 5 3 2 Remove the failed fan s wiring from the motherboard 3 Lift the failed fan from the chassis and pull it completely out from the mother board 4 Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan indicating air direction point in the same...

Страница 54: ...the two power supply units fail the remaining power supply will take over for the failed unit The failed power supply can be replaced without having to power down the server Replacing the Power Supply 1 While the server is running push the release tab on the back of the power supply as illustrated 2 Pull the failed power supply out using the handle provided 3 Replace the failed power module with a...

Страница 55: ...I2 C Cables It is necessary to correctly route the I2 C cables to avoid interference due to noise on the I2 C lines Using tie wraps secure the I2 C cables to the large black power switch ing cable to keep it close to the power supply and away from the motherboard ...

Страница 56: ...SC819 Chassis Manual 5 16 Notes ...

Страница 57: ...re generated You will also need it placed near a grounded power outlet Be sure to read the Rack Cautions and General Server Cautions in the next section of this manual 6 3 Preparing for Setup The box your chassis was shipped in should include two sets of rail assemblies two rail mounting brackets and the mounting screws needed to install the system into a rack Please read this section in its entir...

Страница 58: ...me unstable General Server Precautions Review the electrical and general safety precautions that came with the com ponents you are adding to your chassis Determine the placement of each component in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work up Use a regulating uninterruptable power supply UPS to protect the server fro...

Страница 59: ... overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connec tions other than the direct connectio...

Страница 60: ...k between 26 and 33 5 deep Identifying the Sections of the Rail Assemblies The chassis package includes rail assemblies in the rack mounting kit Each assembly consists of two sections an inner rail and an inner rail extension which mount directly onto the chassis and an outer rail which is secured to the rack Figure 6 1 Identifying the Sections of the Rail Assemblies Optional Inner Rail Extensions...

Страница 61: ...d the front of the chassis 3 Secure the inner rail extension with two screws 4 Repeat steps 1 3 for the other inner rail extension Optional Inner Rail Extensions The SC819 chassis includes a set of inner rails which are in two sections front inner rails and optional inner rail extensions The inner rails are pre attached and do not interfere with normal use of the chasis if you decide not to use a ...

Страница 62: ...red to the rack 2 Adjust both sections of the outer rail to the proper length so that the rail fits snugly within the rack 3 Secure the longer section of the outer rail to the front of the rack with two M5 screws and the shorter section to the rear side of the rack with two M5 screws 4 Repeat steps 1 3 for the remaining outer rail Secure to the Front of the Rack Secure to the Rear of the Rack Figu...

Страница 63: ...keeping the pressure even on both sides It may be necessary to depress the locking tabs when inserting the inner rails When the server has been pushed completely into the rack the locking tabs will click into the locked position 4 Optional Insert and tighten the thumbscrews that hold the front of the server to the rack Inner Rail Extensions Inner Rails Outer Rails Stability hazard The rack stabili...

Страница 64: ...SC819 Chassis Manual 6 8 Figure 6 5 Installing the Chassis into the Rack Note figures are for illustrative purposes only Servers should always be installed in racks from the bottom up ...

Страница 65: ...uded with SC819 Chassis Models SC819TQ R700UB Part Type Length Description CBL 0157L Round ribbon cable 9 8 pin to 8 pin ribbon cable for SGPIO CBL 0191L Round control cable 19 5 20 pin to 20 pin cable CBL 0180L 01 Round cable Varies Set of four SATA 70 59 48 38 cm round cables CBL 0139L Round cable Varies Set of SATA 70 59 48 38 cm round cables SC819TQ R700WB Part Type Length Description CBL 0157...

Страница 66: ... 1 Part CBL 0175L Alt Name Big Four Description This cable has one SFF 8484 32 pin connector on one end and four SAS connectors with seven pins each at the other This cable connects from the host motherboard or other controller to the backplane SAS hard drive port Description This cable has one iPass SFF 8087 Mini SAS connector 36 pin at one end and four SAS connectors on the other end This cable ...

Страница 67: ...20 pin CBL 0059 7 9 20 cm 8 pin CBL 0062 7 9 20 cm 4 pin CBL 0060 7 9 20 cm Front Panel to the Motherboard The SC819 chassis includes a cable to connect the chassis front panel to the motherboard If your motherboard uses a different connector use the following list to find a compatible cable Front Panel to Motherboard Cable Ribbon Cable Number of Pins Front Panel Number of Pins Motherboard Cable P...

Страница 68: ...d M4 x 4 mm 0 157 RAIL Round head M4 x 4 mm 0 157 Flat head M5 x 12 mm 0 472 Washer for M5 DVD ROM CD ROM and FLOPPY DRIVE Flat head 6 32 x 5 mm 0 197 Pan head 6 32 x 5 mm 0 197 Round head M3 x 5 mm 0 197 Pan head 6 32 x 5 mm 0 197 M B Flat head 6 32 x 5 mm 0 197 HARD DRIVE Thumb screw 6 32 x 5 mm 0 197 M B standoff 6 32 to 6 32 M B STANDOFFS M B CPU standoff M5 to 6 32 Round head M2 6 x 5 mm 0 19...

Страница 69: ...fications for your chassis system Power Supply Specifications 700W MFR Part PWS 703P 1R AC Input 700W 100 140 V 50 60 Hz 8 5 6 Amp 750W 180 240 V 60 50 Hz 5 3 8 Amp DC Output 5V standby 3 Amp DC Output 12V 700W 58 Amp at 100 140V 750W 62 Amp at 180 240V With Power Distributor 5V 25 Amp 3 3V 25 Amp 12V 0 6 Amp ...

Страница 70: ...SC819 Chassis Manual B 2 Notes ...

Страница 71: ...tic discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the card and peripherals back into their antistatic bags when not in use C 2 General Safety Guidelines Always disconnect power ...

Страница 72: ...s shown in this manual C 4 Introduction to the SAS 815TQ Backplane The SAS 815TQ backplane has been designed to utilize the most up to date tech nology available providing your system with reliable high quality performance This manual reflects SAS 815TQ Revision 1 00 the most current release available at the time of publication Always refer to the Supermicro Web site at www supermi cro com for the...

Страница 73: ... 5V 12V 1 2 3 0 ACT IN ACT0 ACT1 JTAG UPGRADE JP29 9071 RST JP18 BUZZER RESET ACT2 ACT3 SIDEBAND M9 M15 JP10 D3 JP18 J8 J7 J6 J5 JP29 JP44 R144 MH2 M46 J9 J10 JP26 JP47 JP46 JP42 JP33 JP34 JP40 JP51 REV 1 00 SAS815TQ S UPER R SAS Ports Front Connectors and Components C 5 Front Connectors 1 Power Connectors 4 pin JP10 2 CD ROM Floppy Drive Power Connector J9 and J10 3 JTAG JP47 4 Upgrade Connector ...

Страница 74: ...ctors should be used by a certified and experienced technician Backplane Main Power 4 Pin Connector Pin Definition 1 12V 2 and 3 Ground 4 5V 1 Backplane Main Power Connectors The 4 pin connectors designated JP10 provide power to the backplane See the table on the right for pin definitions 2 CD ROM Floppy 4 Pin Connectors The 4 pin connectors designated J9 and J10 provide power to the CD ROM and fl...

Страница 75: ...o monitor HDD activity and status See the table on the right for pin definitions I2 C Connector Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection SAS Activity LED Header Pin Definitions Pin Definition Pin Definition 1 ACT IN 0 6 ACT IN 4 2 ACT IN 1 7 ACT IN 5 3 ACT IN 2 8 ACT IN 6 4 ACT IN 3 9 ACT IN 7 5 Ground 10 Empty 8 Activity LED Header The activity LED header designated ...

Страница 76: ...abled Buzzer reset JP29 Open Default Closed Reset MG9071 chip reset 5V GND GND 12V 2 I C 5V 12V 5V 12V 1 2 3 0 ACT IN ACT0 ACT1 JTAG UPGRADE JP29 9071 RST JP18 BUZZER RESET ACT2 ACT3 SIDEBAND M9 M15 JP10 D3 JP18 J8 J7 J6 J5 JP29 JP44 R144 MH2 M46 J9 J10 JP26 JP47 JP46 JP42 JP33 JP34 JP40 JP51 REV 1 00 SAS815TQ S UPER R JP18 2 I C 5V 12V 1 0 ACT IN ACT0 ACT1 JP29 9071 RST JP18 BUZZER RESET ACT2 ACT...

Страница 77: ...PIO Setting Jumper Jumper Setting Note JP33 Pins 1 2 Controller ID JP34 Pins 1 2 ID 0 Backplane ID JP40 Closed I2 C Reset SD OUT JP42 Pins 1 2 Backplane ID SDIN JP50 Open I2 C Reset 5V GND GND 12V 2 I C 5V 12V 5V 12V 1 2 3 0 ACT IN ACT0 ACT1 JTAG UPGRADE JP29 9071 RST JP18 BUZZER RESET ACT2 ACT3 SIDEBAND M9 M15 JP10 D3 JP18 J8 J7 J6 J5 JP29 JP44 R144 MH2 M46 J9 J10 JP26 JP47 JP46 JP42 JP33 JP34 JP...

Страница 78: ...onnectors Rear Connector Connector Number SAS Drive Number SAS 0 J1 SAS SATA HDD 0 SAS 1 J2 SAS SATA HDD 1 SAS 2 J3 SAS SATA HDD 2 SAS 3 J4 SAS SATA HDD 3 D12 D5 SAS 0 D13 D6 SAS 1 SAS 2 SAS 3 D14 D7 D15 D8 Rear LED Indicators Rear Connector Hard Drive Activity Failure LED SAS 0 D12 D5 SAS 1 D13 D6 SAS 2 D14 D7 SAS 3 D15 D8 Figure C 5 Rear Connectors and LED Indicators ...

Страница 79: ...C 9 Appendix C SAS 815TQ Backplane Specifications Notes ...

Страница 80: ... reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims deman...