D-5
Appendix D: Backplane
*The buzzer sound indicates that a condition requiring immediate attention has
occurred.
The buzzer alarm is triggered by the following condition:
System temperature over 50º Celsius.
D-7 Front Jumper
Locations and Pin Definitions
Socket Settings
Jumper
Setting
Note
JP18
Open: No reset (Default)
Closed: Reset
Buzzer reset*
JP25
Open: 45º C
Pins 1-2: 50º C (Default)
Pins 2-3: 55º C
Overheat temperature setting
Figure D-2: Front Jumpers
JP25
JP18
Explanation of Jumpers
To modify the operation of the backplane,
jumpers can be used to choose between
optional settings. Jumpers create shorts be-
tween two pins to change the function of the
connector. Pin 1 is identified with a square
solder pad on the printed circuit board. Note:
On two pin jumpers, "Closed" means the
jumper is on and "Open" means the jumper
is off the pins.
Connector
Pins
Jumper
Setting
3 2 1
3 2 1