Chapter 6: Advanced Chassis Setup
6-3
6-3 System
Fans
Four 4-cm heavy duty counter-rotating fans provide the cooling for the 1021M-UR+.
Each fan unit is actually made up of two fans joined back-to-back, which rotate in
opposite directions. This counter-rotating action generates exceptional airfl ow and
works to dampen vibration levels. It is very important that the chassis top cover is
properly installed and making a good seal in order for the cooling air to circulate
properly through the chassis and cool the components. See Figure 6-2. (An optional
5th fan can be added to the far left fan position.)
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the
remaining fan will ramp up to full speed and the Universal Information LED on the
control panel will blink red quickly. Replace any failed fan at your earliest conve-
nience with the same type and model (the system can continue to run with a failed
fan). Remove the top chassis cover while the system is still running to determine
which of the two fans has failed. Then power down the system before replacing a
fan. Removing the power cords is also recommended as a safety precaution.
Replacing System Fans
1. Removing a fan
After turning off the power to the system, fi rst remove the chassis cover and unplug
the fan cable from the motherboard. Unscrew the failed blower fan from the chassis
and pull it completely out from the serverboard.
2. Installing a new fan
Replace the failed fan with an identical 4-cm, 12 volt fan (available from Supermicro:
p/n FAN-0086L). Push the new fan into the vacant space in the housing while mak-
ing sure the arrows on the top of the fan (indicating air direction) point in the same
direction as the arrows on the other fans. Reposition the fan housing back over
the two mounting posts in the chassis, then reconnect the fan wires to the same
chassis fan headers you removed them from. Power up the system and check that
the fan is working properly and that the LED on the control panel has turned off.
Finish by replacing the chassis cover.
Содержание AS1021M-UR Plus
Страница 1: ...AS1021M UR USER S MANUAL 1 0a SUPER ...
Страница 5: ...v Preface Notes ...
Страница 10: ...Notes x 1021M UR User s Manual ...
Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System ...
Страница 72: ...6 10 AS1021M UR User s Manual Figure 6 6 Removing Replacing the Power Supply ...
Страница 92: ...A 2 AS1021M UR User s Manual Notes ...
Страница 100: ...B 8 AS1021M UR User s Manual Notes ...
Страница 104: ...C 4 AS1021M UR User s Manual Notes ...