7-12
A+ Server 1012A-MRF USER'S MANUAL
Hardware Health Configuration
CPU Overheat Alarm
This setting allows you to specify the type of alarm for CPU overheating. Options
include The Early Alarm and
The Default Alarm
.
Fan Speed Control Modes
This feature allows the user to determine how the system will control the speed
of the onboard fans. The options are Full Speed/FS (Max Cooling), Performance/
PF (Better Cooling),
Balanced/BL
(Balance between performance and energy
saving), Energy Saving/ES (Lower Power and Noise).
Other items in the submenu are systems monitor displays for the following
information:
CPU Temperature, System Temperature, Fan 1-5 Reading, CPU VCore, CPU
Mem, 1.1V, 1.8V, 5V, +12V, -12V, 3.3 Vcc, 3.3 VSB, VBAT and HT Voltage.
CPU Temperature Display (CTD)
CPU Temperature descriptions are defined as:
Low
[Tctl Value = Lowest Value, Tctl Value = 45]
Medium
[Tctl Value = 46, Tctl Value = 60]
High
[Tctl Value = 61 and Above]
Note: Only CPU temperature (Low, Medium, High) and system temperature (RT1)
are required to be displayed in BIOS and in-system monitoring software. Other
Motherboard components such as memory, chipset, SAS and 10Gb controllers,
and others are not requried to display temperatures. For debugging and testing
purposes, BIOS and system monitoring software can show motherboard
components’ temperatures (such as memory, chipset, SAS and 10Gb controllers).
However for SMCI standard release version BIOS and system monitoring software,
motherboard components’ temperatures are NOT required to be displayed.
CPU Overheating Alarm (COA)
CPU Overheating Alarm (COA) has “
Early Alarm
” and “
Default Alarm
” (default)
options in the BIOS, and is required to be implemented in all fan speed control
modes.
The
Early Alarm
is enabled when the Tctl value = 65, and is disabled when the Tctl
value drops from 65 to 62.
The
Default Alarm
(default setting) is enabled when the Tctl value = 70, and is
disabled when the Tctl value drops from 70 to 67.
Содержание A+ 1012A-MRF
Страница 1: ...A Server 1012A MRF SUPER USER S MANUAL 1 0a ...
Страница 8: ...A Server 1012A MRF User s Manual viii Notes ...
Страница 14: ...1 6 A Server 1012A MRF User s Manual Notes ...
Страница 22: ...2 8 A 1012A MRF User s Manual Notes ...
Страница 46: ...4 20 A Server 1012A MRF User s Manuall Notes ...
Страница 80: ...6 2 A Server 1012A MRF User s Manual Notes ...
Страница 100: ...A 2 A Server 1012A MRF User s Manual Notes ...
Страница 107: ...C 1 Appendix C System Specifications Notes ...